Cargando…

Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study

PURPOSE: The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. MATERIALS AND METHODS: Twelve human skull bones containing posterior-mandibular alveol...

Descripción completa

Detalles Bibliográficos
Autores principales: Tayman, Mahmure Ayşe, Kamburoğlu, Kıvanç, Ocak, Mert, Özen, Doğukan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9226237/
https://www.ncbi.nlm.nih.gov/pubmed/35799972
http://dx.doi.org/10.5624/isd.20220025
_version_ 1784733822435196928
author Tayman, Mahmure Ayşe
Kamburoğlu, Kıvanç
Ocak, Mert
Özen, Doğukan
author_facet Tayman, Mahmure Ayşe
Kamburoğlu, Kıvanç
Ocak, Mert
Özen, Doğukan
author_sort Tayman, Mahmure Ayşe
collection PubMed
description PURPOSE: The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. MATERIALS AND METHODS: Twelve human skull bones containing posterior-mandibular alveolar bone regions were analyzed. CBCT images were obtained at voxel sizes of 0.075 mm (high: HI) and 0.2 mm (standard: Std), while micro-CT imaging used voxel sizes of 0.06 mm (HI) and 0.12 mm (Std). Analyses were performed using CTAn software with the standardized automatic global threshold method. Intraclass correlation coefficients were used to evaluate the consistency and agreement of paired measurements for bone volume (BV), percent bone volume (BV/TV), bone surface (BS), trabecular thickness (TbTh), trabecular separation (TbSp), trabecular number (TbN), trabecular pattern factor (TbPf), and structure model index (SMI). RESULTS: When compared to micro-CT, CBCT images had higher BV, BV/TV, and TbTh values, while micro-CT images had lower BS, TbSp, TbN, TbPf, and SMI values (P<0.05). The BV, BV/BT, TbTh, and TbSp variables were higher with Std voxels, whereas the BS, TbPf, and SMI variables were higher with HI voxels for both imaging methods. For each imaging modality and voxel size evaluated, BV, BS, and TbTh were significantly different (P<0.05). TbN, TbPf, and SMI showed statistically significant differences between imaging methods (P<0.05). The consistency and absolute agreement between micro-CT and CBCT were excellent for all variables. CONCLUSION: This study demonstrated the potential of high-resolution CBCT imaging for quantitative bone morphometry assessment.
format Online
Article
Text
id pubmed-9226237
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-92262372022-07-06 Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study Tayman, Mahmure Ayşe Kamburoğlu, Kıvanç Ocak, Mert Özen, Doğukan Imaging Sci Dent Original Article PURPOSE: The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. MATERIALS AND METHODS: Twelve human skull bones containing posterior-mandibular alveolar bone regions were analyzed. CBCT images were obtained at voxel sizes of 0.075 mm (high: HI) and 0.2 mm (standard: Std), while micro-CT imaging used voxel sizes of 0.06 mm (HI) and 0.12 mm (Std). Analyses were performed using CTAn software with the standardized automatic global threshold method. Intraclass correlation coefficients were used to evaluate the consistency and agreement of paired measurements for bone volume (BV), percent bone volume (BV/TV), bone surface (BS), trabecular thickness (TbTh), trabecular separation (TbSp), trabecular number (TbN), trabecular pattern factor (TbPf), and structure model index (SMI). RESULTS: When compared to micro-CT, CBCT images had higher BV, BV/TV, and TbTh values, while micro-CT images had lower BS, TbSp, TbN, TbPf, and SMI values (P<0.05). The BV, BV/BT, TbTh, and TbSp variables were higher with Std voxels, whereas the BS, TbPf, and SMI variables were higher with HI voxels for both imaging methods. For each imaging modality and voxel size evaluated, BV, BS, and TbTh were significantly different (P<0.05). TbN, TbPf, and SMI showed statistically significant differences between imaging methods (P<0.05). The consistency and absolute agreement between micro-CT and CBCT were excellent for all variables. CONCLUSION: This study demonstrated the potential of high-resolution CBCT imaging for quantitative bone morphometry assessment. Korean Academy of Oral and Maxillofacial Radiology 2022-06 2022-04-28 /pmc/articles/PMC9226237/ /pubmed/35799972 http://dx.doi.org/10.5624/isd.20220025 Text en Copyright © 2022 by Korean Academy of Oral and Maxillofacial Radiology https://creativecommons.org/licenses/by-nc/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0 (https://creativecommons.org/licenses/by-nc/3.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Tayman, Mahmure Ayşe
Kamburoğlu, Kıvanç
Ocak, Mert
Özen, Doğukan
Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study
title Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study
title_full Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study
title_fullStr Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study
title_full_unstemmed Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study
title_short Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study
title_sort effect of different voxel sizes on the accuracy of cbct measurements of trabecular bone microstructure: a comparative micro-ct study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9226237/
https://www.ncbi.nlm.nih.gov/pubmed/35799972
http://dx.doi.org/10.5624/isd.20220025
work_keys_str_mv AT taymanmahmureayse effectofdifferentvoxelsizesontheaccuracyofcbctmeasurementsoftrabecularbonemicrostructureacomparativemicroctstudy
AT kamburoglukıvanc effectofdifferentvoxelsizesontheaccuracyofcbctmeasurementsoftrabecularbonemicrostructureacomparativemicroctstudy
AT ocakmert effectofdifferentvoxelsizesontheaccuracyofcbctmeasurementsoftrabecularbonemicrostructureacomparativemicroctstudy
AT ozendogukan effectofdifferentvoxelsizesontheaccuracyofcbctmeasurementsoftrabecularbonemicrostructureacomparativemicroctstudy