Cargando…

A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor

The micro-claw pole stepper motor is widely used in the field of camera modules and VR focusing. The influence of torque ripple on positioning accuracy becomes more obvious with a decrease in motor volume. In order to reduce the torque ripple of the micro-claw stepper motor and increase the load cap...

Descripción completa

Detalles Bibliográficos
Autores principales: Xi, Xiaofei, Sun, Yan, Wang, Xudong, Xin, Yuanxu, Yang, Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9227333/
https://www.ncbi.nlm.nih.gov/pubmed/35744546
http://dx.doi.org/10.3390/mi13060931
_version_ 1784734148701716480
author Xi, Xiaofei
Sun, Yan
Wang, Xudong
Xin, Yuanxu
Yang, Yong
author_facet Xi, Xiaofei
Sun, Yan
Wang, Xudong
Xin, Yuanxu
Yang, Yong
author_sort Xi, Xiaofei
collection PubMed
description The micro-claw pole stepper motor is widely used in the field of camera modules and VR focusing. The influence of torque ripple on positioning accuracy becomes more obvious with a decrease in motor volume. In order to reduce the torque ripple of the micro-claw stepper motor and increase the load capacity of the motor, the torque of the motor is simulated by using finite element software. Firstly, the influences of four parameters, namely air gap, magnet thickness, claw thickness and claw height, on the detent torque and holding torque of the claw permanent magnet stepper motor are obtained through the Taguchi experiment. The Signal-to-noise ratio (SNR) of each factor to the response was calculated and the degree of influence of the four parameters on the detent torque and holding torque of the micro-claw pole permanent magnet stepper motor was determined. Then, the optimal value of each factor to reduce the detent torque and increase the holding torque was obtained through optimization analysis. Finally, experiments were carried out to test the holding torque of the motor, and the accuracy of the results was verified by comparing the test values with the simulation values. According to the analysis of the paper, the response delta of air gap to detent torque is the largest, reaching 5.99, and that to holding torque is 0.73. The response delta of the magnet thickness to the detent torque is 5.87, and the response delta to the holding torque is 1.52. The optimized parameters obtained by optimization analysis reduce the detent torque of the motor by 26.74% and increase the holding torque by 18.35%. It is found that air gap and permanent magnet thickness have the greatest influence on the detent torque and holding torque of a micro-claw permanent magnet stepper motor, followed by claw thickness and claw height. Among them, the air gap has more influence on the detent torque than on the holding torque, and the thickness of the permanent magnet has more influence on the holding torque than on the detent torque.
format Online
Article
Text
id pubmed-9227333
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92273332022-06-25 A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor Xi, Xiaofei Sun, Yan Wang, Xudong Xin, Yuanxu Yang, Yong Micromachines (Basel) Article The micro-claw pole stepper motor is widely used in the field of camera modules and VR focusing. The influence of torque ripple on positioning accuracy becomes more obvious with a decrease in motor volume. In order to reduce the torque ripple of the micro-claw stepper motor and increase the load capacity of the motor, the torque of the motor is simulated by using finite element software. Firstly, the influences of four parameters, namely air gap, magnet thickness, claw thickness and claw height, on the detent torque and holding torque of the claw permanent magnet stepper motor are obtained through the Taguchi experiment. The Signal-to-noise ratio (SNR) of each factor to the response was calculated and the degree of influence of the four parameters on the detent torque and holding torque of the micro-claw pole permanent magnet stepper motor was determined. Then, the optimal value of each factor to reduce the detent torque and increase the holding torque was obtained through optimization analysis. Finally, experiments were carried out to test the holding torque of the motor, and the accuracy of the results was verified by comparing the test values with the simulation values. According to the analysis of the paper, the response delta of air gap to detent torque is the largest, reaching 5.99, and that to holding torque is 0.73. The response delta of the magnet thickness to the detent torque is 5.87, and the response delta to the holding torque is 1.52. The optimized parameters obtained by optimization analysis reduce the detent torque of the motor by 26.74% and increase the holding torque by 18.35%. It is found that air gap and permanent magnet thickness have the greatest influence on the detent torque and holding torque of a micro-claw permanent magnet stepper motor, followed by claw thickness and claw height. Among them, the air gap has more influence on the detent torque than on the holding torque, and the thickness of the permanent magnet has more influence on the holding torque than on the detent torque. MDPI 2022-06-11 /pmc/articles/PMC9227333/ /pubmed/35744546 http://dx.doi.org/10.3390/mi13060931 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xi, Xiaofei
Sun, Yan
Wang, Xudong
Xin, Yuanxu
Yang, Yong
A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor
title A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor
title_full A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor
title_fullStr A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor
title_full_unstemmed A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor
title_short A Study on the Detent Torque and Holding Torque of a Micro-Claw Pole Stepper Motor
title_sort study on the detent torque and holding torque of a micro-claw pole stepper motor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9227333/
https://www.ncbi.nlm.nih.gov/pubmed/35744546
http://dx.doi.org/10.3390/mi13060931
work_keys_str_mv AT xixiaofei astudyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT sunyan astudyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT wangxudong astudyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT xinyuanxu astudyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT yangyong astudyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT xixiaofei studyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT sunyan studyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT wangxudong studyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT xinyuanxu studyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor
AT yangyong studyonthedetenttorqueandholdingtorqueofamicroclawpolesteppermotor