Cargando…
Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study
(1) Objective: To evaluate and compare the depth of cure (DOC) of two bulk-fill flowable composites (Filtek Bulk Fill Flowable Restorative and Tetric EvoFlow Bulk Fill), two conventional flowable composites (Filtek Supreme XTE Flowable Restorative and G-ænial Flo X) and one high-strength universal i...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228197/ https://www.ncbi.nlm.nih.gov/pubmed/35745293 http://dx.doi.org/10.3390/nano12121951 |
_version_ | 1784734377041723392 |
---|---|
author | Ludovichetti, Francesco Saverio Lucchi, Patrizia Zambon, Giulia Pezzato, Luca Bertolini, Rachele Zerman, Nicoletta Stellini, Edoardo Mazzoleni, Sergio |
author_facet | Ludovichetti, Francesco Saverio Lucchi, Patrizia Zambon, Giulia Pezzato, Luca Bertolini, Rachele Zerman, Nicoletta Stellini, Edoardo Mazzoleni, Sergio |
author_sort | Ludovichetti, Francesco Saverio |
collection | PubMed |
description | (1) Objective: To evaluate and compare the depth of cure (DOC) of two bulk-fill flowable composites (Filtek Bulk Fill Flowable Restorative and Tetric EvoFlow Bulk Fill), two conventional flowable composites (Filtek Supreme XTE Flowable Restorative and G-ænial Flo X) and one high-strength universal injectable composite (G-ænial Universal Injectable). (2) Methods: specimens were placed in a stainless-steel mold with an orifice of 4 mm in diameter and 10 mm in depth and light-cured for 20 s using a light emitting diode (LED) light-curing unit (LCU) with an irradiance of 1000 mW/cm(2); depth of cure was assessed using the ISO 4049 scrape technique, and the absolute length of the specimen of cured composite was measured in millimeters with a digital caliper. The same procedure was repeated with 14 samples for each material under investigation, for a total number of 70 test bodies. Material roughness and hardness results were also investigated using, respectively, a 3D laser confocal microscope (LEXT OLS 4100; Olympus) at ×5 magnification and a Vickers diamond indenter (Vickers microhardness tester, Shimadzu(®), Kyoto, Japan) under 10-N load and a 30 s dwell time. SEM images at 3000 and 9000 magnification were collected in order to study the materials’ filler content. Statistical analysis were performed by a commercial statistical software package (SPSS) and data were analyzed using multiple comparison Dunnett’s test. (3) Results: The average DOC of both bulk-fill composites was more than 4 mm, as a range of 3.91 and 4.53 mm with an average value of 4.24 and 4.12 mm, while that of the conventional flowable composites was much lower, as a range of 2.47 and 2.90 mm with an average value of 2.58 and 2.84 mm; DOC of the high-strength injectable composite was greater than the one of traditional composites, but not to the level of bulk-fill materials, as a range of 2.82 and 3.01 mm with an average value of 3.02 mm. Statistical analysis revealed significant differences (p-values < 0.05) in the depth of cure between bulk fill flowable composites and other composites, while there was no difference (p-values > 0.05) between the materials of the same type. (4) Conclusions: Bulk-fill flowable composites showed significantly higher depth of cure values than both traditional flowable composites and high-strength injectable composites. |
format | Online Article Text |
id | pubmed-9228197 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92281972022-06-25 Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study Ludovichetti, Francesco Saverio Lucchi, Patrizia Zambon, Giulia Pezzato, Luca Bertolini, Rachele Zerman, Nicoletta Stellini, Edoardo Mazzoleni, Sergio Nanomaterials (Basel) Article (1) Objective: To evaluate and compare the depth of cure (DOC) of two bulk-fill flowable composites (Filtek Bulk Fill Flowable Restorative and Tetric EvoFlow Bulk Fill), two conventional flowable composites (Filtek Supreme XTE Flowable Restorative and G-ænial Flo X) and one high-strength universal injectable composite (G-ænial Universal Injectable). (2) Methods: specimens were placed in a stainless-steel mold with an orifice of 4 mm in diameter and 10 mm in depth and light-cured for 20 s using a light emitting diode (LED) light-curing unit (LCU) with an irradiance of 1000 mW/cm(2); depth of cure was assessed using the ISO 4049 scrape technique, and the absolute length of the specimen of cured composite was measured in millimeters with a digital caliper. The same procedure was repeated with 14 samples for each material under investigation, for a total number of 70 test bodies. Material roughness and hardness results were also investigated using, respectively, a 3D laser confocal microscope (LEXT OLS 4100; Olympus) at ×5 magnification and a Vickers diamond indenter (Vickers microhardness tester, Shimadzu(®), Kyoto, Japan) under 10-N load and a 30 s dwell time. SEM images at 3000 and 9000 magnification were collected in order to study the materials’ filler content. Statistical analysis were performed by a commercial statistical software package (SPSS) and data were analyzed using multiple comparison Dunnett’s test. (3) Results: The average DOC of both bulk-fill composites was more than 4 mm, as a range of 3.91 and 4.53 mm with an average value of 4.24 and 4.12 mm, while that of the conventional flowable composites was much lower, as a range of 2.47 and 2.90 mm with an average value of 2.58 and 2.84 mm; DOC of the high-strength injectable composite was greater than the one of traditional composites, but not to the level of bulk-fill materials, as a range of 2.82 and 3.01 mm with an average value of 3.02 mm. Statistical analysis revealed significant differences (p-values < 0.05) in the depth of cure between bulk fill flowable composites and other composites, while there was no difference (p-values > 0.05) between the materials of the same type. (4) Conclusions: Bulk-fill flowable composites showed significantly higher depth of cure values than both traditional flowable composites and high-strength injectable composites. MDPI 2022-06-07 /pmc/articles/PMC9228197/ /pubmed/35745293 http://dx.doi.org/10.3390/nano12121951 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ludovichetti, Francesco Saverio Lucchi, Patrizia Zambon, Giulia Pezzato, Luca Bertolini, Rachele Zerman, Nicoletta Stellini, Edoardo Mazzoleni, Sergio Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study |
title | Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study |
title_full | Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study |
title_fullStr | Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study |
title_full_unstemmed | Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study |
title_short | Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study |
title_sort | depth of cure, hardness, roughness and filler dimension of bulk-fill flowable, conventional flowable and high-strength universal injectable composites: an in vitro study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228197/ https://www.ncbi.nlm.nih.gov/pubmed/35745293 http://dx.doi.org/10.3390/nano12121951 |
work_keys_str_mv | AT ludovichettifrancescosaverio depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy AT lucchipatrizia depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy AT zambongiulia depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy AT pezzatoluca depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy AT bertolinirachele depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy AT zermannicoletta depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy AT stelliniedoardo depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy AT mazzolenisergio depthofcurehardnessroughnessandfillerdimensionofbulkfillflowableconventionalflowableandhighstrengthuniversalinjectablecompositesaninvitrostudy |