Cargando…
The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance
Approximately two-thirds of anthropogenic emissions causing global warming are from carbon dioxide. Carbon capture is essential, with membranes proving to be a low cost and energy-efficient solution to alternative technologies. In particular, mixed matrix membranes (MMMs) can have higher permeabilit...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228675/ https://www.ncbi.nlm.nih.gov/pubmed/35736290 http://dx.doi.org/10.3390/membranes12060584 |
_version_ | 1784734539801690112 |
---|---|
author | Lasseuguette, Elsa Fielder-Dunton, Louise Jian, Qian Ferrari, Maria-Chiara |
author_facet | Lasseuguette, Elsa Fielder-Dunton, Louise Jian, Qian Ferrari, Maria-Chiara |
author_sort | Lasseuguette, Elsa |
collection | PubMed |
description | Approximately two-thirds of anthropogenic emissions causing global warming are from carbon dioxide. Carbon capture is essential, with membranes proving to be a low cost and energy-efficient solution to alternative technologies. In particular, mixed matrix membranes (MMMs) can have higher permeability and selectivity than pure polymer membranes. The fabrication conditions affect the formation of defects within the membranes. In this work, MMMs were created using a PEBAX MH-1657 polymer and a ZIF-8 filler. The effect of casting plate temperature, varying from −5 °C to 50 °C, and the effect of ultrasound treatment time (80–400 min) and method (filler solution only, filler and polymer combined solution only and filler solution followed by combined solution) were investigated, aiming to reduce defect formations hence improving the performance of the MMMs. SEM images and permeation tests using pure CO(2) and N(2) gas, replicating flue gas for carbon capture, were used to investigate and compare the membranes morphology and performance. The results indicated that the MMMs maintained their permeabilities and selectivities at all tested casting temperatures. However, the neat PEBAX membranes demonstrated increased phase separation of the polyamide and polyether oxide phases at higher temperatures, causing a reduction in permeability due to the higher crystallinity degree, confirmed by DSC experiment. The MMMs fabricated at low ultrasound times displayed a large amount of aggregation with large particle size causing channeling. At high ultrasound times, a well-dispersed filler with small filler diameters was observed, providing a high membrane performance. Overall, defect-free membranes were successfully fabricated, leading to improved performance, with the best membrane resulting from the longest ultrasound time reaching the Robeson bound upper limits. |
format | Online Article Text |
id | pubmed-9228675 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92286752022-06-25 The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance Lasseuguette, Elsa Fielder-Dunton, Louise Jian, Qian Ferrari, Maria-Chiara Membranes (Basel) Article Approximately two-thirds of anthropogenic emissions causing global warming are from carbon dioxide. Carbon capture is essential, with membranes proving to be a low cost and energy-efficient solution to alternative technologies. In particular, mixed matrix membranes (MMMs) can have higher permeability and selectivity than pure polymer membranes. The fabrication conditions affect the formation of defects within the membranes. In this work, MMMs were created using a PEBAX MH-1657 polymer and a ZIF-8 filler. The effect of casting plate temperature, varying from −5 °C to 50 °C, and the effect of ultrasound treatment time (80–400 min) and method (filler solution only, filler and polymer combined solution only and filler solution followed by combined solution) were investigated, aiming to reduce defect formations hence improving the performance of the MMMs. SEM images and permeation tests using pure CO(2) and N(2) gas, replicating flue gas for carbon capture, were used to investigate and compare the membranes morphology and performance. The results indicated that the MMMs maintained their permeabilities and selectivities at all tested casting temperatures. However, the neat PEBAX membranes demonstrated increased phase separation of the polyamide and polyether oxide phases at higher temperatures, causing a reduction in permeability due to the higher crystallinity degree, confirmed by DSC experiment. The MMMs fabricated at low ultrasound times displayed a large amount of aggregation with large particle size causing channeling. At high ultrasound times, a well-dispersed filler with small filler diameters was observed, providing a high membrane performance. Overall, defect-free membranes were successfully fabricated, leading to improved performance, with the best membrane resulting from the longest ultrasound time reaching the Robeson bound upper limits. MDPI 2022-05-31 /pmc/articles/PMC9228675/ /pubmed/35736290 http://dx.doi.org/10.3390/membranes12060584 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lasseuguette, Elsa Fielder-Dunton, Louise Jian, Qian Ferrari, Maria-Chiara The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance |
title | The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance |
title_full | The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance |
title_fullStr | The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance |
title_full_unstemmed | The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance |
title_short | The Effect of Solution Casting Temperature and Ultrasound Treatment on PEBAX MH-1657/ZIF-8 Mixed Matrix Membranes Morphology and Performance |
title_sort | effect of solution casting temperature and ultrasound treatment on pebax mh-1657/zif-8 mixed matrix membranes morphology and performance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228675/ https://www.ncbi.nlm.nih.gov/pubmed/35736290 http://dx.doi.org/10.3390/membranes12060584 |
work_keys_str_mv | AT lasseuguetteelsa theeffectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance AT fielderduntonlouise theeffectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance AT jianqian theeffectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance AT ferrarimariachiara theeffectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance AT lasseuguetteelsa effectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance AT fielderduntonlouise effectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance AT jianqian effectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance AT ferrarimariachiara effectofsolutioncastingtemperatureandultrasoundtreatmentonpebaxmh1657zif8mixedmatrixmembranesmorphologyandperformance |