Cargando…
Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon
The orientation of antibodies, employed as capture molecules on biosensors, determines biorecognition efficiency and bioassay performance. In a previous publication we demonstrated for antibodies attached covalently to silicon that an increase in their surface amount Γ, evaluated with ellipsometry,...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228713/ https://www.ncbi.nlm.nih.gov/pubmed/35744796 http://dx.doi.org/10.3390/molecules27123672 |
_version_ | 1784734547802324992 |
---|---|
author | Gajos, Katarzyna Petrou, Panagiota Budkowski, Andrzej |
author_facet | Gajos, Katarzyna Petrou, Panagiota Budkowski, Andrzej |
author_sort | Gajos, Katarzyna |
collection | PubMed |
description | The orientation of antibodies, employed as capture molecules on biosensors, determines biorecognition efficiency and bioassay performance. In a previous publication we demonstrated for antibodies attached covalently to silicon that an increase in their surface amount Γ, evaluated with ellipsometry, induces changes in their orientation, which is traced directly using Time-of-Flight Secondary Ion Mass Spectroscopy combined with Principal Component Analysis. Here, we extend the above studies to antibodies adsorbed physically on a 3-aminopropyltriethoxysilane (APTES) monolayer. Antibodies physisorbed on APTES (0 ≤ Γ ≤ 3.5 mg/m(2)) reveal the Γ ranges for flat-on, side-on, and vertical orientation consistent with random molecular packing. The relation between orientation and Γ is juxtaposed for silicon functionalized with APTES, APTES modified with glutaraldehyde (APTES/GA) and N-hydroxysuccinimide-silane (NHS-silane). Antibody reorientation occurs at lower Γ values when physisorption (APTES) is involved rather than chemisorption (APTES/GA, NHS-silane). At high Γ values, comparable proportions of molecules adapting head-on and tail-on vertical alignment are concluded for APTES and the NHS-silane monolayer, and they are related to intermolecular dipole–dipole interactions. Intermolecular forces seem to be less decisive than covalent binding for antibodies on the APTES/GA surface, with dominant head-on orientation. Independently, the impact of glutaraldehyde activation of APTES on vertical orientation is confirmed by separate TOF-SIMS measurements. |
format | Online Article Text |
id | pubmed-9228713 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92287132022-06-25 Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon Gajos, Katarzyna Petrou, Panagiota Budkowski, Andrzej Molecules Communication The orientation of antibodies, employed as capture molecules on biosensors, determines biorecognition efficiency and bioassay performance. In a previous publication we demonstrated for antibodies attached covalently to silicon that an increase in their surface amount Γ, evaluated with ellipsometry, induces changes in their orientation, which is traced directly using Time-of-Flight Secondary Ion Mass Spectroscopy combined with Principal Component Analysis. Here, we extend the above studies to antibodies adsorbed physically on a 3-aminopropyltriethoxysilane (APTES) monolayer. Antibodies physisorbed on APTES (0 ≤ Γ ≤ 3.5 mg/m(2)) reveal the Γ ranges for flat-on, side-on, and vertical orientation consistent with random molecular packing. The relation between orientation and Γ is juxtaposed for silicon functionalized with APTES, APTES modified with glutaraldehyde (APTES/GA) and N-hydroxysuccinimide-silane (NHS-silane). Antibody reorientation occurs at lower Γ values when physisorption (APTES) is involved rather than chemisorption (APTES/GA, NHS-silane). At high Γ values, comparable proportions of molecules adapting head-on and tail-on vertical alignment are concluded for APTES and the NHS-silane monolayer, and they are related to intermolecular dipole–dipole interactions. Intermolecular forces seem to be less decisive than covalent binding for antibodies on the APTES/GA surface, with dominant head-on orientation. Independently, the impact of glutaraldehyde activation of APTES on vertical orientation is confirmed by separate TOF-SIMS measurements. MDPI 2022-06-07 /pmc/articles/PMC9228713/ /pubmed/35744796 http://dx.doi.org/10.3390/molecules27123672 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Gajos, Katarzyna Petrou, Panagiota Budkowski, Andrzej Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon |
title | Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon |
title_full | Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon |
title_fullStr | Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon |
title_full_unstemmed | Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon |
title_short | Comparison of Physical Adsorption and Covalent Coupling Methods for Surface Density-Dependent Orientation of Antibody on Silicon |
title_sort | comparison of physical adsorption and covalent coupling methods for surface density-dependent orientation of antibody on silicon |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9228713/ https://www.ncbi.nlm.nih.gov/pubmed/35744796 http://dx.doi.org/10.3390/molecules27123672 |
work_keys_str_mv | AT gajoskatarzyna comparisonofphysicaladsorptionandcovalentcouplingmethodsforsurfacedensitydependentorientationofantibodyonsilicon AT petroupanagiota comparisonofphysicaladsorptionandcovalentcouplingmethodsforsurfacedensitydependentorientationofantibodyonsilicon AT budkowskiandrzej comparisonofphysicaladsorptionandcovalentcouplingmethodsforsurfacedensitydependentorientationofantibodyonsilicon |