Cargando…

Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study

BACKGROUND: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is an established diagnostic procedure for solid pancreatic mass. However, the diagnostic yield between fine-needle aspiration (FNA) and fine-needle biopsy (FNB) remains unclear. We aimed to evaluate and compare the diagnostic yiel...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Thanawin, Pattarapuntakul, Tanawat, Netinatsunton, Nisa, Ovartlarnporn, Bancha, Sottisuporn, Jaksin, Chamroonkul, Naichaya, Sripongpun, Pimsiri, Jandee, Sawangpong, Kaewdech, Apichat, Attasaranya, Siriboon, Piratvisuth, Teerha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9229075/
https://www.ncbi.nlm.nih.gov/pubmed/35751053
http://dx.doi.org/10.1186/s12957-022-02682-3
_version_ 1784734647453745152
author Wong, Thanawin
Pattarapuntakul, Tanawat
Netinatsunton, Nisa
Ovartlarnporn, Bancha
Sottisuporn, Jaksin
Chamroonkul, Naichaya
Sripongpun, Pimsiri
Jandee, Sawangpong
Kaewdech, Apichat
Attasaranya, Siriboon
Piratvisuth, Teerha
author_facet Wong, Thanawin
Pattarapuntakul, Tanawat
Netinatsunton, Nisa
Ovartlarnporn, Bancha
Sottisuporn, Jaksin
Chamroonkul, Naichaya
Sripongpun, Pimsiri
Jandee, Sawangpong
Kaewdech, Apichat
Attasaranya, Siriboon
Piratvisuth, Teerha
author_sort Wong, Thanawin
collection PubMed
description BACKGROUND: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is an established diagnostic procedure for solid pancreatic mass. However, the diagnostic yield between fine-needle aspiration (FNA) and fine-needle biopsy (FNB) remains unclear. We aimed to evaluate and compare the diagnostic yields between FNA and FNB using conventional FNA and Franseen needles of the same size 22-gauge needle, in patients with solid pancreatic mass who underwent EUS-TA without rapid onsite cytopathology evaluation (ROSE). METHODS: All cases of EUS-TA by FNA or FNB for solid pancreatic mass between January 2017 and October 2020 in a single-centre university hospital were retrospectively reviewed. All procedures were performed without an onsite cytologist. Before the endoscopist finished the procedure, macroscopic onsite evaluation (MOSE) was confirmed. The diagnostic yield and the average number of needle passes between FNB and FNA were then compared. RESULTS: A total of 151 patients (FNA, n = 77; FNB, n = 74) with solid pancreatic mass detected by cross-sectional imaging underwent EUS-TA. The mean age was 62.3 ± 12.8 years, with 88 (58.3%) males. Age, sex, mass location, tumour size and disease stage from imaging were not significantly different between the two groups. The diagnostic performance was higher in EUS-FNB (94.6%) than in EUS-FNA (89.6%). The mean number of needle passes was clearly fewer in FNB than in FNA (2.8 vs. 3.8, p < 0.001). The total procedure time was shorter in FNB (34.7 min) than in FNA (41 min). The adverse event rate between FNB and FNA was not significantly different. CONCLUSIONS: The diagnostic yield of solid pancreatic mass was higher in FNB using the Franseen needle than in FNA using the conventional FNA needle in a centre where ROSE is unavailable, without serious adverse event. In addition, FNB had fewer needle passes and shorter total procedure time.
format Online
Article
Text
id pubmed-9229075
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-92290752022-06-25 Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study Wong, Thanawin Pattarapuntakul, Tanawat Netinatsunton, Nisa Ovartlarnporn, Bancha Sottisuporn, Jaksin Chamroonkul, Naichaya Sripongpun, Pimsiri Jandee, Sawangpong Kaewdech, Apichat Attasaranya, Siriboon Piratvisuth, Teerha World J Surg Oncol Research BACKGROUND: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is an established diagnostic procedure for solid pancreatic mass. However, the diagnostic yield between fine-needle aspiration (FNA) and fine-needle biopsy (FNB) remains unclear. We aimed to evaluate and compare the diagnostic yields between FNA and FNB using conventional FNA and Franseen needles of the same size 22-gauge needle, in patients with solid pancreatic mass who underwent EUS-TA without rapid onsite cytopathology evaluation (ROSE). METHODS: All cases of EUS-TA by FNA or FNB for solid pancreatic mass between January 2017 and October 2020 in a single-centre university hospital were retrospectively reviewed. All procedures were performed without an onsite cytologist. Before the endoscopist finished the procedure, macroscopic onsite evaluation (MOSE) was confirmed. The diagnostic yield and the average number of needle passes between FNB and FNA were then compared. RESULTS: A total of 151 patients (FNA, n = 77; FNB, n = 74) with solid pancreatic mass detected by cross-sectional imaging underwent EUS-TA. The mean age was 62.3 ± 12.8 years, with 88 (58.3%) males. Age, sex, mass location, tumour size and disease stage from imaging were not significantly different between the two groups. The diagnostic performance was higher in EUS-FNB (94.6%) than in EUS-FNA (89.6%). The mean number of needle passes was clearly fewer in FNB than in FNA (2.8 vs. 3.8, p < 0.001). The total procedure time was shorter in FNB (34.7 min) than in FNA (41 min). The adverse event rate between FNB and FNA was not significantly different. CONCLUSIONS: The diagnostic yield of solid pancreatic mass was higher in FNB using the Franseen needle than in FNA using the conventional FNA needle in a centre where ROSE is unavailable, without serious adverse event. In addition, FNB had fewer needle passes and shorter total procedure time. BioMed Central 2022-06-24 /pmc/articles/PMC9229075/ /pubmed/35751053 http://dx.doi.org/10.1186/s12957-022-02682-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wong, Thanawin
Pattarapuntakul, Tanawat
Netinatsunton, Nisa
Ovartlarnporn, Bancha
Sottisuporn, Jaksin
Chamroonkul, Naichaya
Sripongpun, Pimsiri
Jandee, Sawangpong
Kaewdech, Apichat
Attasaranya, Siriboon
Piratvisuth, Teerha
Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study
title Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study
title_full Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study
title_fullStr Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study
title_full_unstemmed Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study
title_short Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study
title_sort diagnostic performance of endoscopic ultrasound-guided tissue acquisition by eus-fna versus eus-fnb for solid pancreatic mass without rose: a retrospective study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9229075/
https://www.ncbi.nlm.nih.gov/pubmed/35751053
http://dx.doi.org/10.1186/s12957-022-02682-3
work_keys_str_mv AT wongthanawin diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT pattarapuntakultanawat diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT netinatsuntonnisa diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT ovartlarnpornbancha diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT sottisupornjaksin diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT chamroonkulnaichaya diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT sripongpunpimsiri diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT jandeesawangpong diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT kaewdechapichat diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT attasaranyasiriboon diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy
AT piratvisuthteerha diagnosticperformanceofendoscopicultrasoundguidedtissueacquisitionbyeusfnaversuseusfnbforsolidpancreaticmasswithoutrosearetrospectivestudy