Cargando…
Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking
Background and Objectives: Freehand distal interlocking of intramedullary nails is technically demanding and prone to handling issues. It requires precise placement of a screw through the nail under fluoroscopy guidance and can result in a time consuming and radiation expensive procedure. Dedicated...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9229787/ https://www.ncbi.nlm.nih.gov/pubmed/35744036 http://dx.doi.org/10.3390/medicina58060773 |
_version_ | 1784734839673454592 |
---|---|
author | Pastor, Torsten Pastor, Tatjana Kastner, Philipp Souleiman, Firas Knobe, Matthias Gueorguiev, Boyko Windolf, Markus Buschbaum, Jan |
author_facet | Pastor, Torsten Pastor, Tatjana Kastner, Philipp Souleiman, Firas Knobe, Matthias Gueorguiev, Boyko Windolf, Markus Buschbaum, Jan |
author_sort | Pastor, Torsten |
collection | PubMed |
description | Background and Objectives: Freehand distal interlocking of intramedullary nails is technically demanding and prone to handling issues. It requires precise placement of a screw through the nail under fluoroscopy guidance and can result in a time consuming and radiation expensive procedure. Dedicated training could help overcome these problems. The aim of this study was to assess construct and face validity of new Digitally Enhanced Hands-On Surgical Training (DEHST) concept and device for training of distal interlocking of intramedullary nails. Materials and Methods: Twenty-nine novices and twenty-four expert surgeons performed interlocking on a DEHST device. Construct validity was evaluated by comparing captured performance metrics—number of X-rays, nail hole roundness, drill tip position and drill hole accuracy—between experts and novices. Face validity was evaluated with a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale. Results: Face validity: mean realism of the training device was rated 6.3 (range 4–7). Training potential and need for distal interlocking training were both rated with a mean of 6.5 (range 5–7), with no significant differences between experts and novices, p ≥ 0.234. All participants (100%) stated that the device is useful for procedural training of distal nail interlocking, 96% wanted to have it at their institution and 98% would recommend it to colleagues. Construct validity: total number of X-rays was significantly higher for novices (20.9 ± 6.4 versus 15.5 ± 5.3, p = 0.003). Success rate (ratio of hit and miss attempts) was significantly higher for experts (novices hit: n = 15; 55.6%; experts hit: n = 19; 83%, p = 0.040). Conclusion: The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was proven by reliably discriminating between experts and novices. Participants indicate high further training potential as the device may be easily adapted to other surgical tasks. |
format | Online Article Text |
id | pubmed-9229787 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92297872022-06-25 Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking Pastor, Torsten Pastor, Tatjana Kastner, Philipp Souleiman, Firas Knobe, Matthias Gueorguiev, Boyko Windolf, Markus Buschbaum, Jan Medicina (Kaunas) Article Background and Objectives: Freehand distal interlocking of intramedullary nails is technically demanding and prone to handling issues. It requires precise placement of a screw through the nail under fluoroscopy guidance and can result in a time consuming and radiation expensive procedure. Dedicated training could help overcome these problems. The aim of this study was to assess construct and face validity of new Digitally Enhanced Hands-On Surgical Training (DEHST) concept and device for training of distal interlocking of intramedullary nails. Materials and Methods: Twenty-nine novices and twenty-four expert surgeons performed interlocking on a DEHST device. Construct validity was evaluated by comparing captured performance metrics—number of X-rays, nail hole roundness, drill tip position and drill hole accuracy—between experts and novices. Face validity was evaluated with a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale. Results: Face validity: mean realism of the training device was rated 6.3 (range 4–7). Training potential and need for distal interlocking training were both rated with a mean of 6.5 (range 5–7), with no significant differences between experts and novices, p ≥ 0.234. All participants (100%) stated that the device is useful for procedural training of distal nail interlocking, 96% wanted to have it at their institution and 98% would recommend it to colleagues. Construct validity: total number of X-rays was significantly higher for novices (20.9 ± 6.4 versus 15.5 ± 5.3, p = 0.003). Success rate (ratio of hit and miss attempts) was significantly higher for experts (novices hit: n = 15; 55.6%; experts hit: n = 19; 83%, p = 0.040). Conclusion: The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was proven by reliably discriminating between experts and novices. Participants indicate high further training potential as the device may be easily adapted to other surgical tasks. MDPI 2022-06-07 /pmc/articles/PMC9229787/ /pubmed/35744036 http://dx.doi.org/10.3390/medicina58060773 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Pastor, Torsten Pastor, Tatjana Kastner, Philipp Souleiman, Firas Knobe, Matthias Gueorguiev, Boyko Windolf, Markus Buschbaum, Jan Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking |
title | Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking |
title_full | Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking |
title_fullStr | Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking |
title_full_unstemmed | Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking |
title_short | Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking |
title_sort | validity of a novel digitally enhanced skills training station for freehand distal interlocking |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9229787/ https://www.ncbi.nlm.nih.gov/pubmed/35744036 http://dx.doi.org/10.3390/medicina58060773 |
work_keys_str_mv | AT pastortorsten validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking AT pastortatjana validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking AT kastnerphilipp validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking AT souleimanfiras validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking AT knobematthias validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking AT gueorguievboyko validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking AT windolfmarkus validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking AT buschbaumjan validityofanoveldigitallyenhancedskillstrainingstationforfreehanddistalinterlocking |