Cargando…
Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples
The voltammetric behaviour of Rhodamine B was studied at a screen-printed carbon electrode (SPCE), by cyclic and differential pulse voltammetry. Cyclic voltammograms exhibited two reduction peaks (designated R1 and R2) generated from the reduction of the parent compound through, first, one electron...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9230127/ https://www.ncbi.nlm.nih.gov/pubmed/35746412 http://dx.doi.org/10.3390/s22124631 |
_version_ | 1784734984202878976 |
---|---|
author | Honeychurch, Kevin C. |
author_facet | Honeychurch, Kevin C. |
author_sort | Honeychurch, Kevin C. |
collection | PubMed |
description | The voltammetric behaviour of Rhodamine B was studied at a screen-printed carbon electrode (SPCE), by cyclic and differential pulse voltammetry. Cyclic voltammograms exhibited two reduction peaks (designated R1 and R2) generated from the reduction of the parent compound through, first, one electron reduction (R1) to give a radical species, and then a further one-electron, one-proton reduction to give a neutral molecule (R2). On the reverse positive-going scan, two oxidation peaks were observed. The first, O1, resulted from the oxidation of the species generated at R2, and the second, O2, through the one-electron oxidation of the amine group. The nature of the redox reactions was further investigated by observing the effect of scan rate and pH on the voltammetric behaviour. The developed SPCE method was evaluated by carrying out Rhodamine B determinations on a spiked and unspiked environmental water sample. A mean recovery of 94.3% with an associated coefficient of variation of 2.9% was obtained. The performance characteristics indicated that reliable data may be obtained for Rhodamine B measurements in environmental water samples using this approach. |
format | Online Article Text |
id | pubmed-9230127 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92301272022-06-25 Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples Honeychurch, Kevin C. Sensors (Basel) Article The voltammetric behaviour of Rhodamine B was studied at a screen-printed carbon electrode (SPCE), by cyclic and differential pulse voltammetry. Cyclic voltammograms exhibited two reduction peaks (designated R1 and R2) generated from the reduction of the parent compound through, first, one electron reduction (R1) to give a radical species, and then a further one-electron, one-proton reduction to give a neutral molecule (R2). On the reverse positive-going scan, two oxidation peaks were observed. The first, O1, resulted from the oxidation of the species generated at R2, and the second, O2, through the one-electron oxidation of the amine group. The nature of the redox reactions was further investigated by observing the effect of scan rate and pH on the voltammetric behaviour. The developed SPCE method was evaluated by carrying out Rhodamine B determinations on a spiked and unspiked environmental water sample. A mean recovery of 94.3% with an associated coefficient of variation of 2.9% was obtained. The performance characteristics indicated that reliable data may be obtained for Rhodamine B measurements in environmental water samples using this approach. MDPI 2022-06-19 /pmc/articles/PMC9230127/ /pubmed/35746412 http://dx.doi.org/10.3390/s22124631 Text en © 2022 by the author. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Honeychurch, Kevin C. Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples |
title | Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples |
title_full | Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples |
title_fullStr | Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples |
title_full_unstemmed | Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples |
title_short | Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples |
title_sort | voltammetric behaviour of rhodamine b at a screen-printed carbon electrode and its trace determination in environmental water samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9230127/ https://www.ncbi.nlm.nih.gov/pubmed/35746412 http://dx.doi.org/10.3390/s22124631 |
work_keys_str_mv | AT honeychurchkevinc voltammetricbehaviourofrhodaminebatascreenprintedcarbonelectrodeanditstracedeterminationinenvironmentalwatersamples |