Cargando…

Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel

Austenitic stainless steel is a vital material in various industries, with excellent heat and corrosion resistance, and is widely used in high-temperature environments as a component for internal combustion engines of transportation vehicles or power plant piping. These components or structures are...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Wan-Kyu, Ha, Sangyul, Kim, Jong-Cheon, Park, Jong-Cheon, Gong, Aokai, Kim, Tae-Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9230938/
https://www.ncbi.nlm.nih.gov/pubmed/35744131
http://dx.doi.org/10.3390/ma15124073
_version_ 1784735204154277888
author Choi, Wan-Kyu
Ha, Sangyul
Kim, Jong-Cheon
Park, Jong-Cheon
Gong, Aokai
Kim, Tae-Won
author_facet Choi, Wan-Kyu
Ha, Sangyul
Kim, Jong-Cheon
Park, Jong-Cheon
Gong, Aokai
Kim, Tae-Won
author_sort Choi, Wan-Kyu
collection PubMed
description Austenitic stainless steel is a vital material in various industries, with excellent heat and corrosion resistance, and is widely used in high-temperature environments as a component for internal combustion engines of transportation vehicles or power plant piping. These components or structures are required to be durable against severe load conditions and oxidation damage in high-temperature environments during their service life. In this regard, in particular, oxidation damage and fatigue life are very important influencing factors, while existing studies have focused on materials and fracture behavior. In order to ensure the fatigue life of austenitic stainless steel, therefore, it is necessary to understand the characteristics of the fracture process with microstructural change including oxidation damage according to the temperature condition. In this work, low-cycle fatigue tests were performed at various temperatures to determine the oxidation damage together with the fatigue life of austenitic stainless steel containing niobium. The characteristics of oxidation damage were analyzed through microstructure observations including scanning electron microscope, energy-dispersive X-ray spectroscopy, and the X-ray diffraction patterns. In addition, a unified low-cycle fatigue life model coupled with the fracture mechanism-based lifetime and the Neu-Sehitoglu model for considering the influence of damage by oxidation was proposed. After the low-cycle fatigue tests at temperatures of 200–800 °C and strain amplitudes of 0.4% and 0.5%, the accuracy of the proposed model was verified by comparing the test results with the predicted fatigue life, and the validity by using the oxidation damage parameters for Mar-M247 was confirmed through sensitivity analysis of the parameters applied in the oxidation damage model. As a result, the average thickness of the oxide layer and the penetration length of the oxide intrusion were predicted with a mean error range of 14.7% and 13%, respectively, and the low-cycle fatigue life was predicted with a ±2 factor accuracy at the measurement temperatures under all experimental conditions.
format Online
Article
Text
id pubmed-9230938
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92309382022-06-25 Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel Choi, Wan-Kyu Ha, Sangyul Kim, Jong-Cheon Park, Jong-Cheon Gong, Aokai Kim, Tae-Won Materials (Basel) Article Austenitic stainless steel is a vital material in various industries, with excellent heat and corrosion resistance, and is widely used in high-temperature environments as a component for internal combustion engines of transportation vehicles or power plant piping. These components or structures are required to be durable against severe load conditions and oxidation damage in high-temperature environments during their service life. In this regard, in particular, oxidation damage and fatigue life are very important influencing factors, while existing studies have focused on materials and fracture behavior. In order to ensure the fatigue life of austenitic stainless steel, therefore, it is necessary to understand the characteristics of the fracture process with microstructural change including oxidation damage according to the temperature condition. In this work, low-cycle fatigue tests were performed at various temperatures to determine the oxidation damage together with the fatigue life of austenitic stainless steel containing niobium. The characteristics of oxidation damage were analyzed through microstructure observations including scanning electron microscope, energy-dispersive X-ray spectroscopy, and the X-ray diffraction patterns. In addition, a unified low-cycle fatigue life model coupled with the fracture mechanism-based lifetime and the Neu-Sehitoglu model for considering the influence of damage by oxidation was proposed. After the low-cycle fatigue tests at temperatures of 200–800 °C and strain amplitudes of 0.4% and 0.5%, the accuracy of the proposed model was verified by comparing the test results with the predicted fatigue life, and the validity by using the oxidation damage parameters for Mar-M247 was confirmed through sensitivity analysis of the parameters applied in the oxidation damage model. As a result, the average thickness of the oxide layer and the penetration length of the oxide intrusion were predicted with a mean error range of 14.7% and 13%, respectively, and the low-cycle fatigue life was predicted with a ±2 factor accuracy at the measurement temperatures under all experimental conditions. MDPI 2022-06-08 /pmc/articles/PMC9230938/ /pubmed/35744131 http://dx.doi.org/10.3390/ma15124073 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Choi, Wan-Kyu
Ha, Sangyul
Kim, Jong-Cheon
Park, Jong-Cheon
Gong, Aokai
Kim, Tae-Won
Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel
title Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel
title_full Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel
title_fullStr Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel
title_full_unstemmed Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel
title_short Oxidation Damage Evolution in Low-Cycle Fatigue Life of Niobium-Stabilized Austenitic Stainless Steel
title_sort oxidation damage evolution in low-cycle fatigue life of niobium-stabilized austenitic stainless steel
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9230938/
https://www.ncbi.nlm.nih.gov/pubmed/35744131
http://dx.doi.org/10.3390/ma15124073
work_keys_str_mv AT choiwankyu oxidationdamageevolutioninlowcyclefatiguelifeofniobiumstabilizedausteniticstainlesssteel
AT hasangyul oxidationdamageevolutioninlowcyclefatiguelifeofniobiumstabilizedausteniticstainlesssteel
AT kimjongcheon oxidationdamageevolutioninlowcyclefatiguelifeofniobiumstabilizedausteniticstainlesssteel
AT parkjongcheon oxidationdamageevolutioninlowcyclefatiguelifeofniobiumstabilizedausteniticstainlesssteel
AT gongaokai oxidationdamageevolutioninlowcyclefatiguelifeofniobiumstabilizedausteniticstainlesssteel
AT kimtaewon oxidationdamageevolutioninlowcyclefatiguelifeofniobiumstabilizedausteniticstainlesssteel