Cargando…

Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs

In this systematic review, we evaluate the efficacy and safety of blood components treated with pathogen reduction technologies (PRTs). We searched the Medline, Embase, Scopus, Ovid, and Cochrane Library to identify RCTs evaluating PRTs. Risk of bias assessment and the Mantel–Haenszel method for dat...

Descripción completa

Detalles Bibliográficos
Autores principales: Pati, Ilaria, Masiello, Francesca, Pupella, Simonetta, Cruciani, Mario, De Angelis, Vincenzo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9231062/
https://www.ncbi.nlm.nih.gov/pubmed/35745493
http://dx.doi.org/10.3390/pathogens11060639
_version_ 1784735236519624704
author Pati, Ilaria
Masiello, Francesca
Pupella, Simonetta
Cruciani, Mario
De Angelis, Vincenzo
author_facet Pati, Ilaria
Masiello, Francesca
Pupella, Simonetta
Cruciani, Mario
De Angelis, Vincenzo
author_sort Pati, Ilaria
collection PubMed
description In this systematic review, we evaluate the efficacy and safety of blood components treated with pathogen reduction technologies (PRTs). We searched the Medline, Embase, Scopus, Ovid, and Cochrane Library to identify RCTs evaluating PRTs. Risk of bias assessment and the Mantel–Haenszel method for data synthesis were used. We included in this review 19 RCTs evaluating 4332 patients (mostly oncohematological patients) receiving blood components treated with three different PRTs. Compared with standard platelets (St-PLTs), the treatment with pathogen-reduced platelets (PR-PLTs) does not increase the occurrence of bleeding events, although a slight increase in the occurrence of severe bleeding events was observed in the overall comparison. No between-groups difference in the occurrence of serious adverse events was observed. PR-PLT recipients had a lower 1 and 24 h CI and CCI. The number of patients with platelet refractoriness and alloimmunization was significantly higher in PR-PLT recipients compared with St-PLT recipients. PR-PLT recipients had a higher number of platelet and RBC transfusions compared with St-PLT recipients, with a shorter transfusion time interval. The quality of evidence for these outcomes was from moderate to high. Blood components treated with PRTs are not implicated in serious adverse events, and PR-PLTs do not have a major effect on the increase in bleeding events. However, treatment with PRTs may require a greater number of transfusions in shorter time intervals and may be implicated in an increase in platelet refractoriness and alloimmunization.
format Online
Article
Text
id pubmed-9231062
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92310622022-06-25 Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs Pati, Ilaria Masiello, Francesca Pupella, Simonetta Cruciani, Mario De Angelis, Vincenzo Pathogens Systematic Review In this systematic review, we evaluate the efficacy and safety of blood components treated with pathogen reduction technologies (PRTs). We searched the Medline, Embase, Scopus, Ovid, and Cochrane Library to identify RCTs evaluating PRTs. Risk of bias assessment and the Mantel–Haenszel method for data synthesis were used. We included in this review 19 RCTs evaluating 4332 patients (mostly oncohematological patients) receiving blood components treated with three different PRTs. Compared with standard platelets (St-PLTs), the treatment with pathogen-reduced platelets (PR-PLTs) does not increase the occurrence of bleeding events, although a slight increase in the occurrence of severe bleeding events was observed in the overall comparison. No between-groups difference in the occurrence of serious adverse events was observed. PR-PLT recipients had a lower 1 and 24 h CI and CCI. The number of patients with platelet refractoriness and alloimmunization was significantly higher in PR-PLT recipients compared with St-PLT recipients. PR-PLT recipients had a higher number of platelet and RBC transfusions compared with St-PLT recipients, with a shorter transfusion time interval. The quality of evidence for these outcomes was from moderate to high. Blood components treated with PRTs are not implicated in serious adverse events, and PR-PLTs do not have a major effect on the increase in bleeding events. However, treatment with PRTs may require a greater number of transfusions in shorter time intervals and may be implicated in an increase in platelet refractoriness and alloimmunization. MDPI 2022-06-01 /pmc/articles/PMC9231062/ /pubmed/35745493 http://dx.doi.org/10.3390/pathogens11060639 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Pati, Ilaria
Masiello, Francesca
Pupella, Simonetta
Cruciani, Mario
De Angelis, Vincenzo
Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs
title Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs
title_full Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs
title_fullStr Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs
title_full_unstemmed Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs
title_short Efficacy and Safety of Pathogen-Reduced Platelets Compared with Standard Apheresis Platelets: A Systematic Review of RCTs
title_sort efficacy and safety of pathogen-reduced platelets compared with standard apheresis platelets: a systematic review of rcts
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9231062/
https://www.ncbi.nlm.nih.gov/pubmed/35745493
http://dx.doi.org/10.3390/pathogens11060639
work_keys_str_mv AT patiilaria efficacyandsafetyofpathogenreducedplateletscomparedwithstandardapheresisplateletsasystematicreviewofrcts
AT masiellofrancesca efficacyandsafetyofpathogenreducedplateletscomparedwithstandardapheresisplateletsasystematicreviewofrcts
AT pupellasimonetta efficacyandsafetyofpathogenreducedplateletscomparedwithstandardapheresisplateletsasystematicreviewofrcts
AT crucianimario efficacyandsafetyofpathogenreducedplateletscomparedwithstandardapheresisplateletsasystematicreviewofrcts
AT deangelisvincenzo efficacyandsafetyofpathogenreducedplateletscomparedwithstandardapheresisplateletsasystematicreviewofrcts