Cargando…

Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants

In tissue engineering, foreign body reactions (FBRs) that may occur after the insertion of medical implants are a considerable challenge. Materials currently used in implants are mainly metals that are non-organic, and the lack of biocompatibility and absence of immune regulations may lead to fibros...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Chong-You, Tsai, Pei-Hsuan, Lin, Ya-Hui, Huang, Chien-Yu, Chung, Johnson H.Y., Chen, Guan-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233272/
https://www.ncbi.nlm.nih.gov/pubmed/35761844
http://dx.doi.org/10.1016/j.mtbio.2022.100326
_version_ 1784735725328007168
author Chen, Chong-You
Tsai, Pei-Hsuan
Lin, Ya-Hui
Huang, Chien-Yu
Chung, Johnson H.Y.
Chen, Guan-Yu
author_facet Chen, Chong-You
Tsai, Pei-Hsuan
Lin, Ya-Hui
Huang, Chien-Yu
Chung, Johnson H.Y.
Chen, Guan-Yu
author_sort Chen, Chong-You
collection PubMed
description In tissue engineering, foreign body reactions (FBRs) that may occur after the insertion of medical implants are a considerable challenge. Materials currently used in implants are mainly metals that are non-organic, and the lack of biocompatibility and absence of immune regulations may lead to fibrosis after long periods of implantation. Here, we introduce a highly biocompatible hybrid interface of graphene oxide (GO) and collagen type I (COL-I), where the topological nanostructure can effectively inhibit the differentiation of fibroblasts into myofibroblasts. The structure and roughness of this coating interface can be easily adjusted at the nanoscale level through changes in the GO concentration, thereby effectively inducing the polarization of macrophages to the M1 state without producing excessive amounts of pro-inflammatory factors. Compared to nanomaterials or the extracellular matrix as an anti-fibrotic interface, this hybrid bio-interface has superior mechanical strength, physical structures, and high inflammation. Evidenced by inorganic materials such as glass, titanium, and nitinol, GO-COL shows great potential for use in medical implants and cell-material interfaces.
format Online
Article
Text
id pubmed-9233272
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-92332722022-06-26 Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants Chen, Chong-You Tsai, Pei-Hsuan Lin, Ya-Hui Huang, Chien-Yu Chung, Johnson H.Y. Chen, Guan-Yu Mater Today Bio Full Length Article In tissue engineering, foreign body reactions (FBRs) that may occur after the insertion of medical implants are a considerable challenge. Materials currently used in implants are mainly metals that are non-organic, and the lack of biocompatibility and absence of immune regulations may lead to fibrosis after long periods of implantation. Here, we introduce a highly biocompatible hybrid interface of graphene oxide (GO) and collagen type I (COL-I), where the topological nanostructure can effectively inhibit the differentiation of fibroblasts into myofibroblasts. The structure and roughness of this coating interface can be easily adjusted at the nanoscale level through changes in the GO concentration, thereby effectively inducing the polarization of macrophages to the M1 state without producing excessive amounts of pro-inflammatory factors. Compared to nanomaterials or the extracellular matrix as an anti-fibrotic interface, this hybrid bio-interface has superior mechanical strength, physical structures, and high inflammation. Evidenced by inorganic materials such as glass, titanium, and nitinol, GO-COL shows great potential for use in medical implants and cell-material interfaces. Elsevier 2022-06-15 /pmc/articles/PMC9233272/ /pubmed/35761844 http://dx.doi.org/10.1016/j.mtbio.2022.100326 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Full Length Article
Chen, Chong-You
Tsai, Pei-Hsuan
Lin, Ya-Hui
Huang, Chien-Yu
Chung, Johnson H.Y.
Chen, Guan-Yu
Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants
title Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants
title_full Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants
title_fullStr Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants
title_full_unstemmed Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants
title_short Controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants
title_sort controllable graphene oxide-based biocompatible hybrid interface as an anti-fibrotic coating for metallic implants
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233272/
https://www.ncbi.nlm.nih.gov/pubmed/35761844
http://dx.doi.org/10.1016/j.mtbio.2022.100326
work_keys_str_mv AT chenchongyou controllablegrapheneoxidebasedbiocompatiblehybridinterfaceasanantifibroticcoatingformetallicimplants
AT tsaipeihsuan controllablegrapheneoxidebasedbiocompatiblehybridinterfaceasanantifibroticcoatingformetallicimplants
AT linyahui controllablegrapheneoxidebasedbiocompatiblehybridinterfaceasanantifibroticcoatingformetallicimplants
AT huangchienyu controllablegrapheneoxidebasedbiocompatiblehybridinterfaceasanantifibroticcoatingformetallicimplants
AT chungjohnsonhy controllablegrapheneoxidebasedbiocompatiblehybridinterfaceasanantifibroticcoatingformetallicimplants
AT chenguanyu controllablegrapheneoxidebasedbiocompatiblehybridinterfaceasanantifibroticcoatingformetallicimplants