Cargando…
Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system
AIMS: Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whethe...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Editorial Society of Bone & Joint Surgery
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233429/ https://www.ncbi.nlm.nih.gov/pubmed/35694779 http://dx.doi.org/10.1302/2633-1462.36.BJO-2022-0055 |
_version_ | 1784735767600300032 |
---|---|
author | Jang, Seong J. Vigdorchik, Jonathan M. Windsor, Eric W. Schwarzkopf, Ran Mayman, David J. Sculco, Peter K. |
author_facet | Jang, Seong J. Vigdorchik, Jonathan M. Windsor, Eric W. Schwarzkopf, Ran Mayman, David J. Sculco, Peter K. |
author_sort | Jang, Seong J. |
collection | PubMed |
description | AIMS: Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. METHODS: A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (Δsacral slope(SS)(stand-sit) > 30°), or stiff (ΔSS(stand-sit) < 10°) spinopelvic mobility contributed to increased error rates. RESULTS: The paired absolute difference between CAS and postoperative imaging measurements was 2.3° (standard deviation (SD) 2.6°) for inclination and 3.1° (SD 4.2°) for anteversion. Using a target zone of 40° (± 10°) (inclination) and 20° (± 10°) (anteversion), postoperative standing radiographs measured 96% of acetabular components within the target zone for both inclination and anteversion. Multiple logistic regression analysis controlling for BMI and sex revealed that hypermobile spinopelvic mobility significantly increased error rates for anteversion (odds ratio (OR) 2.48, p = 0.009) and inclination (OR 2.44, p = 0.016), whereas stiff spinopelvic mobility increased error rates for anteversion (OR 1.97, p = 0.028). There were no dislocations at a minimum three-year follow-up. CONCLUSION: Despite high reliability in acetabular positioning for inclination in a large patient cohort using an optical CAS system, hypermobile and stiff spinopelvic mobility significantly increased the risk of clinically relevant errors. In patients with abnormal spinopelvic mobility, CAS systems should be adjusted for use to avoid acetabular component misalignment and subsequent risk for long-term dislocation. Cite this article: Bone Jt Open 2022;3(6):475–484. |
format | Online Article Text |
id | pubmed-9233429 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The British Editorial Society of Bone & Joint Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-92334292022-06-29 Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system Jang, Seong J. Vigdorchik, Jonathan M. Windsor, Eric W. Schwarzkopf, Ran Mayman, David J. Sculco, Peter K. Bone Jt Open Hip AIMS: Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. METHODS: A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (Δsacral slope(SS)(stand-sit) > 30°), or stiff (ΔSS(stand-sit) < 10°) spinopelvic mobility contributed to increased error rates. RESULTS: The paired absolute difference between CAS and postoperative imaging measurements was 2.3° (standard deviation (SD) 2.6°) for inclination and 3.1° (SD 4.2°) for anteversion. Using a target zone of 40° (± 10°) (inclination) and 20° (± 10°) (anteversion), postoperative standing radiographs measured 96% of acetabular components within the target zone for both inclination and anteversion. Multiple logistic regression analysis controlling for BMI and sex revealed that hypermobile spinopelvic mobility significantly increased error rates for anteversion (odds ratio (OR) 2.48, p = 0.009) and inclination (OR 2.44, p = 0.016), whereas stiff spinopelvic mobility increased error rates for anteversion (OR 1.97, p = 0.028). There were no dislocations at a minimum three-year follow-up. CONCLUSION: Despite high reliability in acetabular positioning for inclination in a large patient cohort using an optical CAS system, hypermobile and stiff spinopelvic mobility significantly increased the risk of clinically relevant errors. In patients with abnormal spinopelvic mobility, CAS systems should be adjusted for use to avoid acetabular component misalignment and subsequent risk for long-term dislocation. Cite this article: Bone Jt Open 2022;3(6):475–484. The British Editorial Society of Bone & Joint Surgery 2022-06-13 /pmc/articles/PMC9233429/ /pubmed/35694779 http://dx.doi.org/10.1302/2633-1462.36.BJO-2022-0055 Text en © 2022 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Hip Jang, Seong J. Vigdorchik, Jonathan M. Windsor, Eric W. Schwarzkopf, Ran Mayman, David J. Sculco, Peter K. Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system |
title | Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system |
title_full | Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system |
title_fullStr | Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system |
title_full_unstemmed | Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system |
title_short | Abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system |
title_sort | abnormal spinopelvic mobility as a risk factor for acetabular placement error in total hip arthroplasty using optical computer-assisted surgical navigation system |
topic | Hip |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233429/ https://www.ncbi.nlm.nih.gov/pubmed/35694779 http://dx.doi.org/10.1302/2633-1462.36.BJO-2022-0055 |
work_keys_str_mv | AT jangseongj abnormalspinopelvicmobilityasariskfactorforacetabularplacementerrorintotalhiparthroplastyusingopticalcomputerassistedsurgicalnavigationsystem AT vigdorchikjonathanm abnormalspinopelvicmobilityasariskfactorforacetabularplacementerrorintotalhiparthroplastyusingopticalcomputerassistedsurgicalnavigationsystem AT windsorericw abnormalspinopelvicmobilityasariskfactorforacetabularplacementerrorintotalhiparthroplastyusingopticalcomputerassistedsurgicalnavigationsystem AT schwarzkopfran abnormalspinopelvicmobilityasariskfactorforacetabularplacementerrorintotalhiparthroplastyusingopticalcomputerassistedsurgicalnavigationsystem AT maymandavidj abnormalspinopelvicmobilityasariskfactorforacetabularplacementerrorintotalhiparthroplastyusingopticalcomputerassistedsurgicalnavigationsystem AT sculcopeterk abnormalspinopelvicmobilityasariskfactorforacetabularplacementerrorintotalhiparthroplastyusingopticalcomputerassistedsurgicalnavigationsystem |