The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant

BACKGROUND: Avulsion fracture of the tibial intercondylar eminence is a rare injury, which mainly occurs in adolescents aged 8–14 years and in those with immature bones. The current commonly used surgery may result in severe surgical trauma, affecting knee joint function and accompanied by serious c...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Libo, Shi, Rongmao, Chen, Zhian, Ding, Wei, Tan, Hongbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233839/
https://www.ncbi.nlm.nih.gov/pubmed/35752828
http://dx.doi.org/10.1186/s13018-022-03219-w
_version_ 1784735898203586560
author Yuan, Libo
Shi, Rongmao
Chen, Zhian
Ding, Wei
Tan, Hongbo
author_facet Yuan, Libo
Shi, Rongmao
Chen, Zhian
Ding, Wei
Tan, Hongbo
author_sort Yuan, Libo
collection PubMed
description BACKGROUND: Avulsion fracture of the tibial intercondylar eminence is a rare injury, which mainly occurs in adolescents aged 8–14 years and in those with immature bones. The current commonly used surgery may result in severe surgical trauma, affecting knee joint function and accompanied by serious complications. In this study, we described an all-inside and all-epiphyseal arthroscopic suture fixation technique for a patient to treat tibial intercondylar eminence fracture. METHODS: ETHIBOND EXCEL-coated braided polyester sutures were used for fixation. Three ETHIBOND sutures were passed through the ACL at 2, 6 and 10 o’clock of the footprint of the ACL and made a cinch-knot loop separately. Under the guidance of ACL tibial locator, three corresponding tibial tunnels were drilled with K-wires at 2, 6 and 10 o’clock of the fracture bed, and the two ends of the suture were pulled out through the tunnel with double-folded steel wire heads. After reduction of the tibial eminence, three sutures were tightened and tied to the medial aspect of the tibial tubercle. RESULTS: After all the surgical treatments surgically performed by this method and following a standard postoperative protocol, our patient's ROM, stability, and functional structural scores all improved significantly. CONCLUSION: This three-point suture technique provides a suitable reduction and stable fixation and is suitable for patients with all types of avulsion fractures of the tibial intercondylar eminence.
format Online
Article
Text
id pubmed-9233839
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-92338392022-06-27 The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant Yuan, Libo Shi, Rongmao Chen, Zhian Ding, Wei Tan, Hongbo J Orthop Surg Res Research BACKGROUND: Avulsion fracture of the tibial intercondylar eminence is a rare injury, which mainly occurs in adolescents aged 8–14 years and in those with immature bones. The current commonly used surgery may result in severe surgical trauma, affecting knee joint function and accompanied by serious complications. In this study, we described an all-inside and all-epiphyseal arthroscopic suture fixation technique for a patient to treat tibial intercondylar eminence fracture. METHODS: ETHIBOND EXCEL-coated braided polyester sutures were used for fixation. Three ETHIBOND sutures were passed through the ACL at 2, 6 and 10 o’clock of the footprint of the ACL and made a cinch-knot loop separately. Under the guidance of ACL tibial locator, three corresponding tibial tunnels were drilled with K-wires at 2, 6 and 10 o’clock of the fracture bed, and the two ends of the suture were pulled out through the tunnel with double-folded steel wire heads. After reduction of the tibial eminence, three sutures were tightened and tied to the medial aspect of the tibial tubercle. RESULTS: After all the surgical treatments surgically performed by this method and following a standard postoperative protocol, our patient's ROM, stability, and functional structural scores all improved significantly. CONCLUSION: This three-point suture technique provides a suitable reduction and stable fixation and is suitable for patients with all types of avulsion fractures of the tibial intercondylar eminence. BioMed Central 2022-06-25 /pmc/articles/PMC9233839/ /pubmed/35752828 http://dx.doi.org/10.1186/s13018-022-03219-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Yuan, Libo
Shi, Rongmao
Chen, Zhian
Ding, Wei
Tan, Hongbo
The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
title The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
title_full The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
title_fullStr The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
title_full_unstemmed The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
title_short The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
title_sort most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233839/
https://www.ncbi.nlm.nih.gov/pubmed/35752828
http://dx.doi.org/10.1186/s13018-022-03219-w
work_keys_str_mv AT yuanlibo themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT shirongmao themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT chenzhian themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT dingwei themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT tanhongbo themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT yuanlibo mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT shirongmao mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT chenzhian mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT dingwei mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant
AT tanhongbo mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant