Cargando…
The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant
BACKGROUND: Avulsion fracture of the tibial intercondylar eminence is a rare injury, which mainly occurs in adolescents aged 8–14 years and in those with immature bones. The current commonly used surgery may result in severe surgical trauma, affecting knee joint function and accompanied by serious c...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233839/ https://www.ncbi.nlm.nih.gov/pubmed/35752828 http://dx.doi.org/10.1186/s13018-022-03219-w |
_version_ | 1784735898203586560 |
---|---|
author | Yuan, Libo Shi, Rongmao Chen, Zhian Ding, Wei Tan, Hongbo |
author_facet | Yuan, Libo Shi, Rongmao Chen, Zhian Ding, Wei Tan, Hongbo |
author_sort | Yuan, Libo |
collection | PubMed |
description | BACKGROUND: Avulsion fracture of the tibial intercondylar eminence is a rare injury, which mainly occurs in adolescents aged 8–14 years and in those with immature bones. The current commonly used surgery may result in severe surgical trauma, affecting knee joint function and accompanied by serious complications. In this study, we described an all-inside and all-epiphyseal arthroscopic suture fixation technique for a patient to treat tibial intercondylar eminence fracture. METHODS: ETHIBOND EXCEL-coated braided polyester sutures were used for fixation. Three ETHIBOND sutures were passed through the ACL at 2, 6 and 10 o’clock of the footprint of the ACL and made a cinch-knot loop separately. Under the guidance of ACL tibial locator, three corresponding tibial tunnels were drilled with K-wires at 2, 6 and 10 o’clock of the fracture bed, and the two ends of the suture were pulled out through the tunnel with double-folded steel wire heads. After reduction of the tibial eminence, three sutures were tightened and tied to the medial aspect of the tibial tubercle. RESULTS: After all the surgical treatments surgically performed by this method and following a standard postoperative protocol, our patient's ROM, stability, and functional structural scores all improved significantly. CONCLUSION: This three-point suture technique provides a suitable reduction and stable fixation and is suitable for patients with all types of avulsion fractures of the tibial intercondylar eminence. |
format | Online Article Text |
id | pubmed-9233839 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92338392022-06-27 The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant Yuan, Libo Shi, Rongmao Chen, Zhian Ding, Wei Tan, Hongbo J Orthop Surg Res Research BACKGROUND: Avulsion fracture of the tibial intercondylar eminence is a rare injury, which mainly occurs in adolescents aged 8–14 years and in those with immature bones. The current commonly used surgery may result in severe surgical trauma, affecting knee joint function and accompanied by serious complications. In this study, we described an all-inside and all-epiphyseal arthroscopic suture fixation technique for a patient to treat tibial intercondylar eminence fracture. METHODS: ETHIBOND EXCEL-coated braided polyester sutures were used for fixation. Three ETHIBOND sutures were passed through the ACL at 2, 6 and 10 o’clock of the footprint of the ACL and made a cinch-knot loop separately. Under the guidance of ACL tibial locator, three corresponding tibial tunnels were drilled with K-wires at 2, 6 and 10 o’clock of the fracture bed, and the two ends of the suture were pulled out through the tunnel with double-folded steel wire heads. After reduction of the tibial eminence, three sutures were tightened and tied to the medial aspect of the tibial tubercle. RESULTS: After all the surgical treatments surgically performed by this method and following a standard postoperative protocol, our patient's ROM, stability, and functional structural scores all improved significantly. CONCLUSION: This three-point suture technique provides a suitable reduction and stable fixation and is suitable for patients with all types of avulsion fractures of the tibial intercondylar eminence. BioMed Central 2022-06-25 /pmc/articles/PMC9233839/ /pubmed/35752828 http://dx.doi.org/10.1186/s13018-022-03219-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yuan, Libo Shi, Rongmao Chen, Zhian Ding, Wei Tan, Hongbo The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant |
title | The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant |
title_full | The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant |
title_fullStr | The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant |
title_full_unstemmed | The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant |
title_short | The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant |
title_sort | most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9233839/ https://www.ncbi.nlm.nih.gov/pubmed/35752828 http://dx.doi.org/10.1186/s13018-022-03219-w |
work_keys_str_mv | AT yuanlibo themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT shirongmao themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT chenzhian themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT dingwei themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT tanhongbo themosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT yuanlibo mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT shirongmao mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT chenzhian mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT dingwei mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant AT tanhongbo mosteconomicalarthroscopicsuturefixationfortibialintercondylareminenceavulsionfracturewithoutanyimplant |