Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry
LC–MS is one of the most important tools for the comprehensive characterization of N-glycans. Despite many efforts to speed up glycan analysis via optimized sample preparation (e.g., faster enzyme digestion in combination with instant or rapid labeling dyes), a major bottleneck remains the rather lo...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9234027/ https://www.ncbi.nlm.nih.gov/pubmed/35614231 http://dx.doi.org/10.1007/s00216-022-04133-0 |
_version_ | 1784735961604685824 |
---|---|
author | Manz, Christian Götze, Michael Frank, Clemens Zappe, Andreas Pagel, Kevin |
author_facet | Manz, Christian Götze, Michael Frank, Clemens Zappe, Andreas Pagel, Kevin |
author_sort | Manz, Christian |
collection | PubMed |
description | LC–MS is one of the most important tools for the comprehensive characterization of N-glycans. Despite many efforts to speed up glycan analysis via optimized sample preparation (e.g., faster enzyme digestion in combination with instant or rapid labeling dyes), a major bottleneck remains the rather long measurement times of HILIC chromatography. Further complication arises from the necessity to concomitantly calibrate with an external standard to allow for accurate retention times and the conversion into more robust GU values. Here we demonstrate the use of an internal calibration strategy for HILIC chromatography to speed up glycan analysis. By reducing the number of utilized dextran oligosaccharides, the calibrant can be spiked directly into the sample such that external calibration runs are no longer required. The minimized dextran ladder shows accurate GU calibration with a minor deviation of well below 1% and can be applied without modifications in sample preparation or data processing. We further demonstrate the simultaneous use of the minimized dextran ladder as calibrant for the estimation of CCS values in traveling wave ion mobility spectrometry. In both cases, the minimized dextran ladder enables the measurement of calibrant and sample in a single HPLC run without losing information or accuracy. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-022-04133-0. |
format | Online Article Text |
id | pubmed-9234027 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-92340272022-06-28 Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry Manz, Christian Götze, Michael Frank, Clemens Zappe, Andreas Pagel, Kevin Anal Bioanal Chem Research Paper LC–MS is one of the most important tools for the comprehensive characterization of N-glycans. Despite many efforts to speed up glycan analysis via optimized sample preparation (e.g., faster enzyme digestion in combination with instant or rapid labeling dyes), a major bottleneck remains the rather long measurement times of HILIC chromatography. Further complication arises from the necessity to concomitantly calibrate with an external standard to allow for accurate retention times and the conversion into more robust GU values. Here we demonstrate the use of an internal calibration strategy for HILIC chromatography to speed up glycan analysis. By reducing the number of utilized dextran oligosaccharides, the calibrant can be spiked directly into the sample such that external calibration runs are no longer required. The minimized dextran ladder shows accurate GU calibration with a minor deviation of well below 1% and can be applied without modifications in sample preparation or data processing. We further demonstrate the simultaneous use of the minimized dextran ladder as calibrant for the estimation of CCS values in traveling wave ion mobility spectrometry. In both cases, the minimized dextran ladder enables the measurement of calibrant and sample in a single HPLC run without losing information or accuracy. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-022-04133-0. Springer Berlin Heidelberg 2022-05-26 2022 /pmc/articles/PMC9234027/ /pubmed/35614231 http://dx.doi.org/10.1007/s00216-022-04133-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Paper Manz, Christian Götze, Michael Frank, Clemens Zappe, Andreas Pagel, Kevin Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry |
title | Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry |
title_full | Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry |
title_fullStr | Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry |
title_full_unstemmed | Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry |
title_short | Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry |
title_sort | dextran as internal calibrant for n-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9234027/ https://www.ncbi.nlm.nih.gov/pubmed/35614231 http://dx.doi.org/10.1007/s00216-022-04133-0 |
work_keys_str_mv | AT manzchristian dextranasinternalcalibrantfornglycananalysisbyliquidchromatographycoupledtoionmobilitymassspectrometry AT gotzemichael dextranasinternalcalibrantfornglycananalysisbyliquidchromatographycoupledtoionmobilitymassspectrometry AT frankclemens dextranasinternalcalibrantfornglycananalysisbyliquidchromatographycoupledtoionmobilitymassspectrometry AT zappeandreas dextranasinternalcalibrantfornglycananalysisbyliquidchromatographycoupledtoionmobilitymassspectrometry AT pagelkevin dextranasinternalcalibrantfornglycananalysisbyliquidchromatographycoupledtoionmobilitymassspectrometry |