Cargando…

Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis

BACKGROUND: Inertial measurement units (IMUs) are useful in monitoring running and alerting running-related injuries in various sports settings. However, the quantitative summaries of the validity and reliability of the measurements from IMUs during running are still lacking. The purpose of this rev...

Descripción completa

Detalles Bibliográficos
Autores principales: Zeng, Ziwei, Liu, Yue, Hu, Xiaoyue, Tang, Meihua, Wang, Lin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9237201/
https://www.ncbi.nlm.nih.gov/pubmed/35759130
http://dx.doi.org/10.1186/s40798-022-00477-0
_version_ 1784736719921217536
author Zeng, Ziwei
Liu, Yue
Hu, Xiaoyue
Tang, Meihua
Wang, Lin
author_facet Zeng, Ziwei
Liu, Yue
Hu, Xiaoyue
Tang, Meihua
Wang, Lin
author_sort Zeng, Ziwei
collection PubMed
description BACKGROUND: Inertial measurement units (IMUs) are useful in monitoring running and alerting running-related injuries in various sports settings. However, the quantitative summaries of the validity and reliability of the measurements from IMUs during running are still lacking. The purpose of this review was to investigate the concurrent validity and test–retest reliability of IMUs for measuring gait spatiotemporal outcomes and lower extremity kinematics of health adults during running. METHODS: PubMed, CINAHL, Embase, Scopus and Web of Science electronic databases were searched from inception until September 2021. The inclusion criteria were as follows: (1) evaluated the validity or reliability of measurements from IMUs, (2) measured specific kinematic outcomes, (3) compared measurements using IMUs with those obtained using reference systems, (4) collected data during running, (5) assessed human beings and (6) were published in English. Eligible articles were reviewed using a modified quality assessment. A meta-analysis was performed to assess the pooled correlation coefficients of validity and reliability. RESULTS: Twenty-five articles were included in the systematic review, and data from 12 were pooled for meta-analysis. The methodological quality of studies ranged from low to moderate. Concurrent validity is excellent for stride length (intraclass correlation coefficient (ICC) (95% confidence interval (CI)) = 0.937 (0.859, 0.972), p < 0.001), step frequency (ICC (95% CI) = 0.926 (0.896, 0.948), r (95% CI) = 0.989 (0.957, 0.997), p  < 0.001) and ankle angle in the sagittal plane (r (95% CI) = 0.939 (0.544, 0.993), p = 0.002), moderate to excellent for stance time (ICC (95% CI) = 0.664 (0.354, 0.845), r (95% CI) = 0.811 (0.701, 0.881), p < 0.001) and good for running speed (ICC (95% CI) = 0.848 (0.523, 0.958), p = 0.0003). The summary Fisher's Z value of flight time was not statistically significant (p = 0.13). Similarly, the stance time showed excellent test–retest reliability (ICC (95% CI) = 0.954 (0.903, 0.978), p < 0.001) and step frequency showed good test–retest reliability (ICC (95% CI) = 0.896 (0.837, 0.933), p < 0.001). CONCLUSIONS: Findings in the current review support IMUs measurement of running gait spatiotemporal parameters, but IMUs measurement of running kinematics on lower extremity joints needs to be reported with caution in healthy adults. Trial Registration: PROSPERO Registration Number: CRD42021279395. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40798-022-00477-0.
format Online
Article
Text
id pubmed-9237201
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-92372012022-06-29 Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis Zeng, Ziwei Liu, Yue Hu, Xiaoyue Tang, Meihua Wang, Lin Sports Med Open Systematic Review BACKGROUND: Inertial measurement units (IMUs) are useful in monitoring running and alerting running-related injuries in various sports settings. However, the quantitative summaries of the validity and reliability of the measurements from IMUs during running are still lacking. The purpose of this review was to investigate the concurrent validity and test–retest reliability of IMUs for measuring gait spatiotemporal outcomes and lower extremity kinematics of health adults during running. METHODS: PubMed, CINAHL, Embase, Scopus and Web of Science electronic databases were searched from inception until September 2021. The inclusion criteria were as follows: (1) evaluated the validity or reliability of measurements from IMUs, (2) measured specific kinematic outcomes, (3) compared measurements using IMUs with those obtained using reference systems, (4) collected data during running, (5) assessed human beings and (6) were published in English. Eligible articles were reviewed using a modified quality assessment. A meta-analysis was performed to assess the pooled correlation coefficients of validity and reliability. RESULTS: Twenty-five articles were included in the systematic review, and data from 12 were pooled for meta-analysis. The methodological quality of studies ranged from low to moderate. Concurrent validity is excellent for stride length (intraclass correlation coefficient (ICC) (95% confidence interval (CI)) = 0.937 (0.859, 0.972), p < 0.001), step frequency (ICC (95% CI) = 0.926 (0.896, 0.948), r (95% CI) = 0.989 (0.957, 0.997), p  < 0.001) and ankle angle in the sagittal plane (r (95% CI) = 0.939 (0.544, 0.993), p = 0.002), moderate to excellent for stance time (ICC (95% CI) = 0.664 (0.354, 0.845), r (95% CI) = 0.811 (0.701, 0.881), p < 0.001) and good for running speed (ICC (95% CI) = 0.848 (0.523, 0.958), p = 0.0003). The summary Fisher's Z value of flight time was not statistically significant (p = 0.13). Similarly, the stance time showed excellent test–retest reliability (ICC (95% CI) = 0.954 (0.903, 0.978), p < 0.001) and step frequency showed good test–retest reliability (ICC (95% CI) = 0.896 (0.837, 0.933), p < 0.001). CONCLUSIONS: Findings in the current review support IMUs measurement of running gait spatiotemporal parameters, but IMUs measurement of running kinematics on lower extremity joints needs to be reported with caution in healthy adults. Trial Registration: PROSPERO Registration Number: CRD42021279395. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40798-022-00477-0. Springer International Publishing 2022-06-27 /pmc/articles/PMC9237201/ /pubmed/35759130 http://dx.doi.org/10.1186/s40798-022-00477-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Systematic Review
Zeng, Ziwei
Liu, Yue
Hu, Xiaoyue
Tang, Meihua
Wang, Lin
Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
title Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
title_full Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
title_fullStr Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
title_full_unstemmed Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
title_short Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
title_sort validity and reliability of inertial measurement units on lower extremity kinematics during running: a systematic review and meta-analysis
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9237201/
https://www.ncbi.nlm.nih.gov/pubmed/35759130
http://dx.doi.org/10.1186/s40798-022-00477-0
work_keys_str_mv AT zengziwei validityandreliabilityofinertialmeasurementunitsonlowerextremitykinematicsduringrunningasystematicreviewandmetaanalysis
AT liuyue validityandreliabilityofinertialmeasurementunitsonlowerextremitykinematicsduringrunningasystematicreviewandmetaanalysis
AT huxiaoyue validityandreliabilityofinertialmeasurementunitsonlowerextremitykinematicsduringrunningasystematicreviewandmetaanalysis
AT tangmeihua validityandreliabilityofinertialmeasurementunitsonlowerextremitykinematicsduringrunningasystematicreviewandmetaanalysis
AT wanglin validityandreliabilityofinertialmeasurementunitsonlowerextremitykinematicsduringrunningasystematicreviewandmetaanalysis