Cargando…

The Japanese lead extraction registry (J‐LEX): Annual report 2020

The Japanese Heart Rhythm Society established a nationwide, mandatory, multi‐center, prospective, observational registry of transvenous lead extraction (TLE) named the Japanese lead extraction registry (J‐LEX) in 2018. We have published the first annual report of J‐LEX with 661 cases from 42 hospita...

Descripción completa

Detalles Bibliográficos
Autores principales: Shoda, Morio, Kusano, Kengo, Goya, Masahiko, Nishii, Nobuhiro, Imai, Katsuhiko, Okamoto, Yoji, Nagashima, Michio, Takegami, Misa, Nakao, Yoko M., Iwanaga, Yoshitaka, Miyamoto, Yoshihiro, Nogami, Akihiko, Shimizu, Wataru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9237310/
https://www.ncbi.nlm.nih.gov/pubmed/35785391
http://dx.doi.org/10.1002/joa3.12720
_version_ 1784736753878302720
author Shoda, Morio
Kusano, Kengo
Goya, Masahiko
Nishii, Nobuhiro
Imai, Katsuhiko
Okamoto, Yoji
Nagashima, Michio
Takegami, Misa
Nakao, Yoko M.
Iwanaga, Yoshitaka
Miyamoto, Yoshihiro
Nogami, Akihiko
Shimizu, Wataru
author_facet Shoda, Morio
Kusano, Kengo
Goya, Masahiko
Nishii, Nobuhiro
Imai, Katsuhiko
Okamoto, Yoji
Nagashima, Michio
Takegami, Misa
Nakao, Yoko M.
Iwanaga, Yoshitaka
Miyamoto, Yoshihiro
Nogami, Akihiko
Shimizu, Wataru
author_sort Shoda, Morio
collection PubMed
description The Japanese Heart Rhythm Society established a nationwide, mandatory, multi‐center, prospective, observational registry of transvenous lead extraction (TLE) named the Japanese lead extraction registry (J‐LEX) in 2018. We have published the first annual report of J‐LEX with 661 cases from 42 hospitals. The second annual report of J‐LEX in 2020 enrolled increased numbers of 785 cases from 75 hospitals. TLE procedure was attempted on patients with an average age of 71.7 years old, male in 72.5% in the hybrid operating room in 57.9%, and in standard OR with a C‐arm fluoroscope in 18.7%. The indication of TLE was an infection in 62.8% and the guideline classification was class‐I in 67.4% and class‐IIa in 23.8%. The average implantation duration of target leads was 7.9 years. Complete removal was achieved in 96.6% of the target leads and clinical success in 98.1% of the patients. Perioperative complications were observed in 7.1% of the patients. One patient died during a TLE operation and the other three patients died in‐hospital (cardiac death in one patient and non‐cardiac in two patients). Although the annual J‐LEX report in 2020 demonstrated an increased number of TLE procedures despite the first pandemic year of coronavirus disease‐2019 (COVID‐19), perioperative complications increased a little in comparison with J‐LEX 2019.
format Online
Article
Text
id pubmed-9237310
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92373102022-06-30 The Japanese lead extraction registry (J‐LEX): Annual report 2020 Shoda, Morio Kusano, Kengo Goya, Masahiko Nishii, Nobuhiro Imai, Katsuhiko Okamoto, Yoji Nagashima, Michio Takegami, Misa Nakao, Yoko M. Iwanaga, Yoshitaka Miyamoto, Yoshihiro Nogami, Akihiko Shimizu, Wataru J Arrhythm Data Article The Japanese Heart Rhythm Society established a nationwide, mandatory, multi‐center, prospective, observational registry of transvenous lead extraction (TLE) named the Japanese lead extraction registry (J‐LEX) in 2018. We have published the first annual report of J‐LEX with 661 cases from 42 hospitals. The second annual report of J‐LEX in 2020 enrolled increased numbers of 785 cases from 75 hospitals. TLE procedure was attempted on patients with an average age of 71.7 years old, male in 72.5% in the hybrid operating room in 57.9%, and in standard OR with a C‐arm fluoroscope in 18.7%. The indication of TLE was an infection in 62.8% and the guideline classification was class‐I in 67.4% and class‐IIa in 23.8%. The average implantation duration of target leads was 7.9 years. Complete removal was achieved in 96.6% of the target leads and clinical success in 98.1% of the patients. Perioperative complications were observed in 7.1% of the patients. One patient died during a TLE operation and the other three patients died in‐hospital (cardiac death in one patient and non‐cardiac in two patients). Although the annual J‐LEX report in 2020 demonstrated an increased number of TLE procedures despite the first pandemic year of coronavirus disease‐2019 (COVID‐19), perioperative complications increased a little in comparison with J‐LEX 2019. John Wiley and Sons Inc. 2022-04-21 /pmc/articles/PMC9237310/ /pubmed/35785391 http://dx.doi.org/10.1002/joa3.12720 Text en © 2022 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of the Japanese Heart Rhythm Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Data Article
Shoda, Morio
Kusano, Kengo
Goya, Masahiko
Nishii, Nobuhiro
Imai, Katsuhiko
Okamoto, Yoji
Nagashima, Michio
Takegami, Misa
Nakao, Yoko M.
Iwanaga, Yoshitaka
Miyamoto, Yoshihiro
Nogami, Akihiko
Shimizu, Wataru
The Japanese lead extraction registry (J‐LEX): Annual report 2020
title The Japanese lead extraction registry (J‐LEX): Annual report 2020
title_full The Japanese lead extraction registry (J‐LEX): Annual report 2020
title_fullStr The Japanese lead extraction registry (J‐LEX): Annual report 2020
title_full_unstemmed The Japanese lead extraction registry (J‐LEX): Annual report 2020
title_short The Japanese lead extraction registry (J‐LEX): Annual report 2020
title_sort japanese lead extraction registry (j‐lex): annual report 2020
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9237310/
https://www.ncbi.nlm.nih.gov/pubmed/35785391
http://dx.doi.org/10.1002/joa3.12720
work_keys_str_mv AT shodamorio thejapaneseleadextractionregistryjlexannualreport2020
AT kusanokengo thejapaneseleadextractionregistryjlexannualreport2020
AT goyamasahiko thejapaneseleadextractionregistryjlexannualreport2020
AT nishiinobuhiro thejapaneseleadextractionregistryjlexannualreport2020
AT imaikatsuhiko thejapaneseleadextractionregistryjlexannualreport2020
AT okamotoyoji thejapaneseleadextractionregistryjlexannualreport2020
AT nagashimamichio thejapaneseleadextractionregistryjlexannualreport2020
AT takegamimisa thejapaneseleadextractionregistryjlexannualreport2020
AT nakaoyokom thejapaneseleadextractionregistryjlexannualreport2020
AT iwanagayoshitaka thejapaneseleadextractionregistryjlexannualreport2020
AT miyamotoyoshihiro thejapaneseleadextractionregistryjlexannualreport2020
AT nogamiakihiko thejapaneseleadextractionregistryjlexannualreport2020
AT shimizuwataru thejapaneseleadextractionregistryjlexannualreport2020
AT thejapaneseleadextractionregistryjlexannualreport2020
AT shodamorio japaneseleadextractionregistryjlexannualreport2020
AT kusanokengo japaneseleadextractionregistryjlexannualreport2020
AT goyamasahiko japaneseleadextractionregistryjlexannualreport2020
AT nishiinobuhiro japaneseleadextractionregistryjlexannualreport2020
AT imaikatsuhiko japaneseleadextractionregistryjlexannualreport2020
AT okamotoyoji japaneseleadextractionregistryjlexannualreport2020
AT nagashimamichio japaneseleadextractionregistryjlexannualreport2020
AT takegamimisa japaneseleadextractionregistryjlexannualreport2020
AT nakaoyokom japaneseleadextractionregistryjlexannualreport2020
AT iwanagayoshitaka japaneseleadextractionregistryjlexannualreport2020
AT miyamotoyoshihiro japaneseleadextractionregistryjlexannualreport2020
AT nogamiakihiko japaneseleadextractionregistryjlexannualreport2020
AT shimizuwataru japaneseleadextractionregistryjlexannualreport2020
AT japaneseleadextractionregistryjlexannualreport2020