Cargando…
Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study
OBJECTIVES: Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) is a novel OCT technology that was specifically designed for home monitoring of neovascular age-related macular degeneration (AMD). First clinical findings have been reported before. This trial investigates an...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9237881/ https://www.ncbi.nlm.nih.gov/pubmed/35760534 http://dx.doi.org/10.1136/bmjopen-2021-055082 |
_version_ | 1784736900402118656 |
---|---|
author | von der Burchard, Claus Sudkamp, Helge Tode, Jan Ehlken, Cristoph Purtskhvanidze, Konstantine Moltmann, Moritz Heimes, Britta Koch, Peter Münst, Michael vom Endt, Malte Kepp, Timo Theisen-Kunde, Dirk König, Inke Hüttmann, Gereon Roider, Johann |
author_facet | von der Burchard, Claus Sudkamp, Helge Tode, Jan Ehlken, Cristoph Purtskhvanidze, Konstantine Moltmann, Moritz Heimes, Britta Koch, Peter Münst, Michael vom Endt, Malte Kepp, Timo Theisen-Kunde, Dirk König, Inke Hüttmann, Gereon Roider, Johann |
author_sort | von der Burchard, Claus |
collection | PubMed |
description | OBJECTIVES: Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) is a novel OCT technology that was specifically designed for home monitoring of neovascular age-related macular degeneration (AMD). First clinical findings have been reported before. This trial investigates an improved prototype for patients with AMD and focusses on device operability and diagnostic accuracy compared with established spectral-domain OCT (SD-OCT). DESIGN: Prospective single-arm diagnostic accuracy study. SETTING: Tertiary care centre (University Eye Clinic). PARTICIPANTS: 46 patients with age-related macular degeneration. INTERVENTIONS: Patients received short training in device handling and then performed multiple self-scans with the SELFF-OCT according to a predefined protocol. Additionally, all eyes were examined with standard SD-OCT, performed by medical personnel. All images were graded by at least 2 masked investigators in a reading centre. PRIMARY OUTCOME MEASURE: Rate of successful self-measurements. SECONDARY OUTCOME MEASURES: Sensitivity and specificity of SELFF-OCT versus SD-OCT for different biomarkers and necessity for antivascular endothelial growth factor (anti-VEGF) treatment. RESULTS: In 86% of all examined eyes, OCT self-acquisition resulted in interpretable retinal OCT volume scans. In these patients, the sensitivity for detection of anti-VEGF treatment necessity was 0.94 (95% CI 0.79 to 0.99) and specificity 0.95 (95% CI 0.82 to 0.99). CONCLUSIONS: SELFF-OCT was used successfully for retinal self-examination in most patients, and it could become a valuable tool for retinal home monitoring in the future. Improvements are in progress to reduce device size and to improve handling, image quality and success rates. TRIAL REGISTRATION NUMBER: DRKS00013755, CIV-17-12-022384. |
format | Online Article Text |
id | pubmed-9237881 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-92378812022-07-08 Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study von der Burchard, Claus Sudkamp, Helge Tode, Jan Ehlken, Cristoph Purtskhvanidze, Konstantine Moltmann, Moritz Heimes, Britta Koch, Peter Münst, Michael vom Endt, Malte Kepp, Timo Theisen-Kunde, Dirk König, Inke Hüttmann, Gereon Roider, Johann BMJ Open Ophthalmology OBJECTIVES: Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) is a novel OCT technology that was specifically designed for home monitoring of neovascular age-related macular degeneration (AMD). First clinical findings have been reported before. This trial investigates an improved prototype for patients with AMD and focusses on device operability and diagnostic accuracy compared with established spectral-domain OCT (SD-OCT). DESIGN: Prospective single-arm diagnostic accuracy study. SETTING: Tertiary care centre (University Eye Clinic). PARTICIPANTS: 46 patients with age-related macular degeneration. INTERVENTIONS: Patients received short training in device handling and then performed multiple self-scans with the SELFF-OCT according to a predefined protocol. Additionally, all eyes were examined with standard SD-OCT, performed by medical personnel. All images were graded by at least 2 masked investigators in a reading centre. PRIMARY OUTCOME MEASURE: Rate of successful self-measurements. SECONDARY OUTCOME MEASURES: Sensitivity and specificity of SELFF-OCT versus SD-OCT for different biomarkers and necessity for antivascular endothelial growth factor (anti-VEGF) treatment. RESULTS: In 86% of all examined eyes, OCT self-acquisition resulted in interpretable retinal OCT volume scans. In these patients, the sensitivity for detection of anti-VEGF treatment necessity was 0.94 (95% CI 0.79 to 0.99) and specificity 0.95 (95% CI 0.82 to 0.99). CONCLUSIONS: SELFF-OCT was used successfully for retinal self-examination in most patients, and it could become a valuable tool for retinal home monitoring in the future. Improvements are in progress to reduce device size and to improve handling, image quality and success rates. TRIAL REGISTRATION NUMBER: DRKS00013755, CIV-17-12-022384. BMJ Publishing Group 2022-06-27 /pmc/articles/PMC9237881/ /pubmed/35760534 http://dx.doi.org/10.1136/bmjopen-2021-055082 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Ophthalmology von der Burchard, Claus Sudkamp, Helge Tode, Jan Ehlken, Cristoph Purtskhvanidze, Konstantine Moltmann, Moritz Heimes, Britta Koch, Peter Münst, Michael vom Endt, Malte Kepp, Timo Theisen-Kunde, Dirk König, Inke Hüttmann, Gereon Roider, Johann Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study |
title | Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study |
title_full | Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study |
title_fullStr | Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study |
title_full_unstemmed | Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study |
title_short | Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study |
title_sort | self-examination low-cost full-field optical coherence tomography (selff-oct) for neovascular age-related macular degeneration: a cross-sectional diagnostic accuracy study |
topic | Ophthalmology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9237881/ https://www.ncbi.nlm.nih.gov/pubmed/35760534 http://dx.doi.org/10.1136/bmjopen-2021-055082 |
work_keys_str_mv | AT vonderburchardclaus selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT sudkamphelge selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT todejan selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT ehlkencristoph selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT purtskhvanidzekonstantine selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT moltmannmoritz selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT heimesbritta selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT kochpeter selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT munstmichael selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT vomendtmalte selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT kepptimo selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT theisenkundedirk selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT koniginke selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT huttmanngereon selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy AT roiderjohann selfexaminationlowcostfullfieldopticalcoherencetomographyselffoctforneovascularagerelatedmaculardegenerationacrosssectionaldiagnosticaccuracystudy |