Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications?
BACKGROUND: In the past, radiographic imaging was of minor relevance in the diagnosis of periprosthetic joint infections (PJI). Since metal artefact reduction sequences (MARS) are available, magnetic resonance imaging (MRI) has become a promising diagnostic tool for the evaluation of hip arthroplast...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9238049/ https://www.ncbi.nlm.nih.gov/pubmed/35764987 http://dx.doi.org/10.1186/s12891-022-05560-x |
_version_ | 1784736940977815552 |
---|---|
author | Busch, André Jäger, Marcus Beck, Sascha Wegner, Alexander Portegys, Erik Wassenaar, Dennis Theysohn, Jens Haubold, Johannes |
author_facet | Busch, André Jäger, Marcus Beck, Sascha Wegner, Alexander Portegys, Erik Wassenaar, Dennis Theysohn, Jens Haubold, Johannes |
author_sort | Busch, André |
collection | PubMed |
description | BACKGROUND: In the past, radiographic imaging was of minor relevance in the diagnosis of periprosthetic joint infections (PJI). Since metal artefact reduction sequences (MARS) are available, magnetic resonance imaging (MRI) has become a promising diagnostic tool for the evaluation of hip arthroplasty implants. The purpose of the present study was to evaluate the efficacy of MARS-MRI in comparison to established diagnostic tools to distinguish between aseptic failure and PJI. METHODS: From July 2018 to September 2019, 33 patients classified as having an aseptic joint effusion were recruited into the study. The group included 22 women and 11 men with a mean age of 70.4 ± 13.7 (42–88) years. In the same period, 12 patients were classified as having a PJI. The group consisted of 9 women and 3 men with a mean age of 72.5 ± 10.6 (54–88) years. MARS-MRI was conducted using the optimized parameters at 1.5 T in a coronal and axial STIR (short-tau-inversion recovery), a non-fat-saturated T2 in coronal view and a non-fat-saturated T1 in transverse view in 45 patients with painful hip after total hip arthroplasty (THA). Normally distributed continuous data were shown as mean ± standard deviation (SD) and compared using student's t-test. Non-normally distributed continuous data were shown as mean and compared using the Mann–Whitney U test. RESULTS: Synovial layering and muscle edema were significant features of periprosthetic joint infection, with sensitivities of 100% and specifities of 63.0—75.0%. The combined specifity and sensitivity levels of synovial layering and muscular edema was 88.0% and 90.0%. Granulomatous synovitis was a significant feature for aseptic failure, with 90.0% sensitivity and 57.0% specifity. CONCLUSION: MARS-MRI is as suitable as standard diagnostic tools to distinguish between aseptic failure and PJI in patients with THA. Further studies with larger patient numbers have to prove whether MARS-MRI could be integral part of PJI diagnostic. |
format | Online Article Text |
id | pubmed-9238049 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92380492022-06-29 Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications? Busch, André Jäger, Marcus Beck, Sascha Wegner, Alexander Portegys, Erik Wassenaar, Dennis Theysohn, Jens Haubold, Johannes BMC Musculoskelet Disord Research Article BACKGROUND: In the past, radiographic imaging was of minor relevance in the diagnosis of periprosthetic joint infections (PJI). Since metal artefact reduction sequences (MARS) are available, magnetic resonance imaging (MRI) has become a promising diagnostic tool for the evaluation of hip arthroplasty implants. The purpose of the present study was to evaluate the efficacy of MARS-MRI in comparison to established diagnostic tools to distinguish between aseptic failure and PJI. METHODS: From July 2018 to September 2019, 33 patients classified as having an aseptic joint effusion were recruited into the study. The group included 22 women and 11 men with a mean age of 70.4 ± 13.7 (42–88) years. In the same period, 12 patients were classified as having a PJI. The group consisted of 9 women and 3 men with a mean age of 72.5 ± 10.6 (54–88) years. MARS-MRI was conducted using the optimized parameters at 1.5 T in a coronal and axial STIR (short-tau-inversion recovery), a non-fat-saturated T2 in coronal view and a non-fat-saturated T1 in transverse view in 45 patients with painful hip after total hip arthroplasty (THA). Normally distributed continuous data were shown as mean ± standard deviation (SD) and compared using student's t-test. Non-normally distributed continuous data were shown as mean and compared using the Mann–Whitney U test. RESULTS: Synovial layering and muscle edema were significant features of periprosthetic joint infection, with sensitivities of 100% and specifities of 63.0—75.0%. The combined specifity and sensitivity levels of synovial layering and muscular edema was 88.0% and 90.0%. Granulomatous synovitis was a significant feature for aseptic failure, with 90.0% sensitivity and 57.0% specifity. CONCLUSION: MARS-MRI is as suitable as standard diagnostic tools to distinguish between aseptic failure and PJI in patients with THA. Further studies with larger patient numbers have to prove whether MARS-MRI could be integral part of PJI diagnostic. BioMed Central 2022-06-28 /pmc/articles/PMC9238049/ /pubmed/35764987 http://dx.doi.org/10.1186/s12891-022-05560-x Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Busch, André Jäger, Marcus Beck, Sascha Wegner, Alexander Portegys, Erik Wassenaar, Dennis Theysohn, Jens Haubold, Johannes Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications? |
title | Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications? |
title_full | Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications? |
title_fullStr | Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications? |
title_full_unstemmed | Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications? |
title_short | Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA): A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications? |
title_sort | metal artefact reduction sequences (mars) in magnetic resonance imaging (mri) after total hip arthroplasty (tha): a non-invasive approach for preoperative differentiation between periprosthetic joint infection (pji) and aseptic complications? |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9238049/ https://www.ncbi.nlm.nih.gov/pubmed/35764987 http://dx.doi.org/10.1186/s12891-022-05560-x |
work_keys_str_mv | AT buschandre metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications AT jagermarcus metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications AT becksascha metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications AT wegneralexander metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications AT portegyserik metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications AT wassenaardennis metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications AT theysohnjens metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications AT hauboldjohannes metalartefactreductionsequencesmarsinmagneticresonanceimagingmriaftertotalhiparthroplastythaanoninvasiveapproachforpreoperativedifferentiationbetweenperiprostheticjointinfectionpjiandasepticcomplications |