Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning

PURPOSE: To present quantitative dosimetric evaluations of five proton pencil beam spot placement techniques. MATERIALS AND METHODS: The spot placement techniques that were investigated include two grid-based (rectilinear grid and hexagonal grid, both commonly available in commercial planning system...

Descripción completa

Detalles Bibliográficos
Autores principales: ur Rehman, Mahboob, Zeidan, Omar A., Willoughby, Twyla, Meeks, Sanford L., Kelly, Patrick, Erhart, Kevin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Particle Therapy Co-operative Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9238129/
https://www.ncbi.nlm.nih.gov/pubmed/35774494
http://dx.doi.org/10.14338/IJPT-21-00022.1
_version_ 1784736962132836352
author ur Rehman, Mahboob
Zeidan, Omar A.
Willoughby, Twyla
Meeks, Sanford L.
Kelly, Patrick
Erhart, Kevin
author_facet ur Rehman, Mahboob
Zeidan, Omar A.
Willoughby, Twyla
Meeks, Sanford L.
Kelly, Patrick
Erhart, Kevin
author_sort ur Rehman, Mahboob
collection PubMed
description PURPOSE: To present quantitative dosimetric evaluations of five proton pencil beam spot placement techniques. MATERIALS AND METHODS: The spot placement techniques that were investigated include two grid-based (rectilinear grid and hexagonal grid, both commonly available in commercial planning systems) and three boundary-contoured (concentric contours, hybrid, and optimized) techniques. Treatment plans were created for two different target volumes, one spherical and one conical. An optimal set of planning parameters was defined for all treatment plans and the impact of spot placement techniques on the plan quality was evaluated in terms of lateral/distal dose falloff, normal tissue sparing, conformity and homogeneity of dose distributions, as well as total number of spots used. RESULTS: The results of this work highlight that for grid-based spot placement techniques, the dose conformity is dependent on target cross-sectional shape perpendicular to beam direction, which changes for each energy layer. This variable conformity problem is mitigated by using boundary contoured spot placement techniques. However, in the case of concentric contours, the conformity is improved but at the cost of decreased homogeneity inside the target. Hybrid and optimized spot placement techniques, which use contoured spots at the boundary and gridlike interior spot patterns, provide more uniform dose distributions inside the target volume while maintaining the improved dose conformity. The optimized spot placement technique improved target coverage, homogeneity of dose, and minimal number of spots. The dependence of these results on spot size is also presented for both target shapes. CONCLUSION: This work illustrates that boundary-contoured spot placement techniques offer marked improvement in dosimetry metrics when compared to commercially available grid-based techniques for a range of proton scanned beam spot sizes.
format Online
Article
Text
id pubmed-9238129
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Particle Therapy Co-operative Group
record_format MEDLINE/PubMed
spelling pubmed-92381292022-06-29 Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning ur Rehman, Mahboob Zeidan, Omar A. Willoughby, Twyla Meeks, Sanford L. Kelly, Patrick Erhart, Kevin Int J Part Ther Original Articles PURPOSE: To present quantitative dosimetric evaluations of five proton pencil beam spot placement techniques. MATERIALS AND METHODS: The spot placement techniques that were investigated include two grid-based (rectilinear grid and hexagonal grid, both commonly available in commercial planning systems) and three boundary-contoured (concentric contours, hybrid, and optimized) techniques. Treatment plans were created for two different target volumes, one spherical and one conical. An optimal set of planning parameters was defined for all treatment plans and the impact of spot placement techniques on the plan quality was evaluated in terms of lateral/distal dose falloff, normal tissue sparing, conformity and homogeneity of dose distributions, as well as total number of spots used. RESULTS: The results of this work highlight that for grid-based spot placement techniques, the dose conformity is dependent on target cross-sectional shape perpendicular to beam direction, which changes for each energy layer. This variable conformity problem is mitigated by using boundary contoured spot placement techniques. However, in the case of concentric contours, the conformity is improved but at the cost of decreased homogeneity inside the target. Hybrid and optimized spot placement techniques, which use contoured spots at the boundary and gridlike interior spot patterns, provide more uniform dose distributions inside the target volume while maintaining the improved dose conformity. The optimized spot placement technique improved target coverage, homogeneity of dose, and minimal number of spots. The dependence of these results on spot size is also presented for both target shapes. CONCLUSION: This work illustrates that boundary-contoured spot placement techniques offer marked improvement in dosimetry metrics when compared to commercially available grid-based techniques for a range of proton scanned beam spot sizes. The Particle Therapy Co-operative Group 2022-01-31 /pmc/articles/PMC9238129/ /pubmed/35774494 http://dx.doi.org/10.14338/IJPT-21-00022.1 Text en ©Copyright 2022 The Author(s) https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed in accordance with Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ).
spellingShingle Original Articles
ur Rehman, Mahboob
Zeidan, Omar A.
Willoughby, Twyla
Meeks, Sanford L.
Kelly, Patrick
Erhart, Kevin
Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning
title Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning
title_full Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning
title_fullStr Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning
title_full_unstemmed Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning
title_short Dosimetric Comparison of Various Spot Placement Techniques in Proton Pencil Beam Scanning
title_sort dosimetric comparison of various spot placement techniques in proton pencil beam scanning
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9238129/
https://www.ncbi.nlm.nih.gov/pubmed/35774494
http://dx.doi.org/10.14338/IJPT-21-00022.1
work_keys_str_mv AT urrehmanmahboob dosimetriccomparisonofvariousspotplacementtechniquesinprotonpencilbeamscanning
AT zeidanomara dosimetriccomparisonofvariousspotplacementtechniquesinprotonpencilbeamscanning
AT willoughbytwyla dosimetriccomparisonofvariousspotplacementtechniquesinprotonpencilbeamscanning
AT meekssanfordl dosimetriccomparisonofvariousspotplacementtechniquesinprotonpencilbeamscanning
AT kellypatrick dosimetriccomparisonofvariousspotplacementtechniquesinprotonpencilbeamscanning
AT erhartkevin dosimetriccomparisonofvariousspotplacementtechniquesinprotonpencilbeamscanning