Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump

The left ventricular outflow tract is a region of the left ventricle that lies between the anterior leaflet of the mitral valve and the ventricular septum. Dynamic left ventricular outflow tract obstruction (LVOTO) has classically been observed in patients with hypertrophic obstructive cardiomyopath...

Descripción completa

Detalles Bibliográficos
Autores principales: Noori, Muhammad Atif Masood, Fichadiya, Hardik, Saeed, Hasham, Jawed, Qirat, Jesani, Shruti, Latif, Asnia, Joshi, Meherwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SMC Media Srl 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9239020/
https://www.ncbi.nlm.nih.gov/pubmed/35774733
http://dx.doi.org/10.12890/2022_003341
_version_ 1784737191586430976
author Noori, Muhammad Atif Masood
Fichadiya, Hardik
Saeed, Hasham
Jawed, Qirat
Jesani, Shruti
Latif, Asnia
Joshi, Meherwan
author_facet Noori, Muhammad Atif Masood
Fichadiya, Hardik
Saeed, Hasham
Jawed, Qirat
Jesani, Shruti
Latif, Asnia
Joshi, Meherwan
author_sort Noori, Muhammad Atif Masood
collection PubMed
description The left ventricular outflow tract is a region of the left ventricle that lies between the anterior leaflet of the mitral valve and the ventricular septum. Dynamic left ventricular outflow tract obstruction (LVOTO) has classically been observed in patients with hypertrophic obstructive cardiomyopathy (HOCM) where it occurs secondary to asymmetric septal hypertrophy and systolic anterior motion (SAM) of the mitral valve. However, there are some instances that lead to hypercontractility of the myocardium, and with a combination of other physiological conditions, result in SAM of a mitral valve leaflet, leading to LVOTO in the absence of phenotype. We present such a case of an acute inferolateral wall myocardial infarction that was complicated by cardiogenic shock, requiring an intra-aortic balloon pump (IABP) and inotropic support which paradoxically provoked LVOTO. A reduction in IABP counterpulsation from 1:1 to 1:3 and the addition of intravenous fluids and a beta blocker resulted in significant improvement in blood pressure with rapid tapering of pressors. Inotropes and IABP, although helpful in cardiogenic shock, have the potential to induce or worsen the LVOTO, which can lead to a vicious cycle of worsening hypotension and increasing adrenergic drive that further deteriorates myocardial viability. Timely diagnosis with an echocardiogram and the withdrawal of inotropic and IABP support has the potential to improve haemodynamics and, thereby, outcome. LEARNING POINTS: Dynamic left ventricular outflow tract obstruction (LVOTO) should be one of the differentials in patients with cardiogenic shock, especially if it is refractory in the setting of an intra-aortic balloon pump. The diagnosis of LVOTO by echocardiography should result in immediate implementation of therapy to eliminate the factors that can potentially intensify the obstruction.
format Online
Article
Text
id pubmed-9239020
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SMC Media Srl
record_format MEDLINE/PubMed
spelling pubmed-92390202022-06-29 Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump Noori, Muhammad Atif Masood Fichadiya, Hardik Saeed, Hasham Jawed, Qirat Jesani, Shruti Latif, Asnia Joshi, Meherwan Eur J Case Rep Intern Med Articles The left ventricular outflow tract is a region of the left ventricle that lies between the anterior leaflet of the mitral valve and the ventricular septum. Dynamic left ventricular outflow tract obstruction (LVOTO) has classically been observed in patients with hypertrophic obstructive cardiomyopathy (HOCM) where it occurs secondary to asymmetric septal hypertrophy and systolic anterior motion (SAM) of the mitral valve. However, there are some instances that lead to hypercontractility of the myocardium, and with a combination of other physiological conditions, result in SAM of a mitral valve leaflet, leading to LVOTO in the absence of phenotype. We present such a case of an acute inferolateral wall myocardial infarction that was complicated by cardiogenic shock, requiring an intra-aortic balloon pump (IABP) and inotropic support which paradoxically provoked LVOTO. A reduction in IABP counterpulsation from 1:1 to 1:3 and the addition of intravenous fluids and a beta blocker resulted in significant improvement in blood pressure with rapid tapering of pressors. Inotropes and IABP, although helpful in cardiogenic shock, have the potential to induce or worsen the LVOTO, which can lead to a vicious cycle of worsening hypotension and increasing adrenergic drive that further deteriorates myocardial viability. Timely diagnosis with an echocardiogram and the withdrawal of inotropic and IABP support has the potential to improve haemodynamics and, thereby, outcome. LEARNING POINTS: Dynamic left ventricular outflow tract obstruction (LVOTO) should be one of the differentials in patients with cardiogenic shock, especially if it is refractory in the setting of an intra-aortic balloon pump. The diagnosis of LVOTO by echocardiography should result in immediate implementation of therapy to eliminate the factors that can potentially intensify the obstruction. SMC Media Srl 2022-05-02 /pmc/articles/PMC9239020/ /pubmed/35774733 http://dx.doi.org/10.12890/2022_003341 Text en © EFIM 2022 This article is licensed under a Commons Attribution Non-Commercial 4.0 License
spellingShingle Articles
Noori, Muhammad Atif Masood
Fichadiya, Hardik
Saeed, Hasham
Jawed, Qirat
Jesani, Shruti
Latif, Asnia
Joshi, Meherwan
Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump
title Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump
title_full Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump
title_fullStr Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump
title_full_unstemmed Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump
title_short Coincidence of Events Causing Paradoxical Hypotension in a Patient with an Intra-Aortic Balloon Pump
title_sort coincidence of events causing paradoxical hypotension in a patient with an intra-aortic balloon pump
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9239020/
https://www.ncbi.nlm.nih.gov/pubmed/35774733
http://dx.doi.org/10.12890/2022_003341
work_keys_str_mv AT noorimuhammadatifmasood coincidenceofeventscausingparadoxicalhypotensioninapatientwithanintraaorticballoonpump
AT fichadiyahardik coincidenceofeventscausingparadoxicalhypotensioninapatientwithanintraaorticballoonpump
AT saeedhasham coincidenceofeventscausingparadoxicalhypotensioninapatientwithanintraaorticballoonpump
AT jawedqirat coincidenceofeventscausingparadoxicalhypotensioninapatientwithanintraaorticballoonpump
AT jesanishruti coincidenceofeventscausingparadoxicalhypotensioninapatientwithanintraaorticballoonpump
AT latifasnia coincidenceofeventscausingparadoxicalhypotensioninapatientwithanintraaorticballoonpump
AT joshimeherwan coincidenceofeventscausingparadoxicalhypotensioninapatientwithanintraaorticballoonpump