Cargando…
Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults
The cross-sectional area (CSA) reference values of the lower extremity nerves in Asians have been rarely reported. For this study, 107 sex- and age-matched, healthy subjects with a mean age of 46 years (range, 24–75 years) were recruited. All subjects underwent standardized nerve conduction studies...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9239665/ https://www.ncbi.nlm.nih.gov/pubmed/35777005 http://dx.doi.org/10.1097/MD.0000000000029842 |
_version_ | 1784737353748709376 |
---|---|
author | Bae, Dae Woong An, Jae Young |
author_facet | Bae, Dae Woong An, Jae Young |
author_sort | Bae, Dae Woong |
collection | PubMed |
description | The cross-sectional area (CSA) reference values of the lower extremity nerves in Asians have been rarely reported. For this study, 107 sex- and age-matched, healthy subjects with a mean age of 46 years (range, 24–75 years) were recruited. All subjects underwent standardized nerve conduction studies of the upper and lower extremities. The CSA was measured unilaterally at 12 sites in the lower extremity nerves, including the femoral, lateral femoral cutaneous, sciatic, common peroneal, superficial peroneal, deep peroneal, tibial, and sural nerves. The CSA significantly correlated with height, weight, and body mass index. The CSA was significantly larger in males than females at most nerves except for the lateral femoral cutaneous, common peroneal (fibular head), and superficial peroneal nerves (distal calf). There was no statistically significant difference between the age groups except for the tibial nerve (ankle). The results of this study provide CSA reference values for the lower extremity nerves including small branches and the values can be useful in the ultrasonographic investigation of various peripheral neuropathies in East Asian populations. |
format | Online Article Text |
id | pubmed-9239665 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-92396652022-06-30 Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults Bae, Dae Woong An, Jae Young Medicine (Baltimore) Research Article The cross-sectional area (CSA) reference values of the lower extremity nerves in Asians have been rarely reported. For this study, 107 sex- and age-matched, healthy subjects with a mean age of 46 years (range, 24–75 years) were recruited. All subjects underwent standardized nerve conduction studies of the upper and lower extremities. The CSA was measured unilaterally at 12 sites in the lower extremity nerves, including the femoral, lateral femoral cutaneous, sciatic, common peroneal, superficial peroneal, deep peroneal, tibial, and sural nerves. The CSA significantly correlated with height, weight, and body mass index. The CSA was significantly larger in males than females at most nerves except for the lateral femoral cutaneous, common peroneal (fibular head), and superficial peroneal nerves (distal calf). There was no statistically significant difference between the age groups except for the tibial nerve (ankle). The results of this study provide CSA reference values for the lower extremity nerves including small branches and the values can be useful in the ultrasonographic investigation of various peripheral neuropathies in East Asian populations. Lippincott Williams & Wilkins 2022-06-30 /pmc/articles/PMC9239665/ /pubmed/35777005 http://dx.doi.org/10.1097/MD.0000000000029842 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. |
spellingShingle | Research Article Bae, Dae Woong An, Jae Young Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults |
title | Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults |
title_full | Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults |
title_fullStr | Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults |
title_full_unstemmed | Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults |
title_short | Cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy Korean adults |
title_sort | cross-sectional area reference values for high-resolution ultrasonography of the lower extremity nerves in healthy korean adults |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9239665/ https://www.ncbi.nlm.nih.gov/pubmed/35777005 http://dx.doi.org/10.1097/MD.0000000000029842 |
work_keys_str_mv | AT baedaewoong crosssectionalareareferencevaluesforhighresolutionultrasonographyofthelowerextremitynervesinhealthykoreanadults AT anjaeyoung crosssectionalareareferencevaluesforhighresolutionultrasonographyofthelowerextremitynervesinhealthykoreanadults |