Cargando…

Development and validation of quantitative optical index of skin blood content

SIGNIFICANCE: We present an approach to estimate with simple instrumentation the amount of red blood cells in the skin microvasculature, designated as parameter [Formula: see text]. Variations of parameter [Formula: see text] are shown to reflect local changes in the quantity of skin red blood cells...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Yu-Hao, Maarek, Jean-Michel I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9243648/
https://www.ncbi.nlm.nih.gov/pubmed/35773754
http://dx.doi.org/10.1117/1.JBO.27.6.065003
_version_ 1784738363623866368
author Peng, Yu-Hao
Maarek, Jean-Michel I.
author_facet Peng, Yu-Hao
Maarek, Jean-Michel I.
author_sort Peng, Yu-Hao
collection PubMed
description SIGNIFICANCE: We present an approach to estimate with simple instrumentation the amount of red blood cells in the skin microvasculature, designated as parameter [Formula: see text]. Variations of parameter [Formula: see text] are shown to reflect local changes in the quantity of skin red blood cells during a venous occlusion challenge. AIM: To validate a simple algebraic model of light transport in skin using the Monte Carlo method and to develop a measure of the red blood cell content in skin microvessels using the Monte Carlo predictions; to guide the development of an instrument to measure experimentally variations of the amount of red blood cells in the skin. APPROACH: Monte Carlo simulations were carried out in a multilayer model of the skin to compute remitted light intensities as a function of distance from the illumination locus for different values of the skin blood content. The simulation results were used to compute parameter [Formula: see text] and its variations with local skin blood content. An experimental setup was developed to measure parameter [Formula: see text] in human volunteers in whom skin blood content of the forearm increased during temporary interruption of the venous outflow. RESULTS: In the simulations, parameter [Formula: see text] was [Formula: see text] in baseline conditions, and it increased in near proportion with the blood content of the skin layers. Measuring the diffusely reflected light intensity 0.5 to 1.2 mm away from the illumination locus was optimal to detect appreciable changes of the reflected light intensity as skin blood content was altered. Parameter [Formula: see text] measured experimentally on the human forearm was [Formula: see text] in baseline conditions it increased at a rate of [Formula: see text] when venous outflow was temporarily interrupted. CONCLUSION: Parameter [Formula: see text] derived experimentally with a two-wavelength diffuse reflectometer can be used to measure local variations of the amount of red blood cells in skin microvessels.
format Online
Article
Text
id pubmed-9243648
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-92436482022-07-02 Development and validation of quantitative optical index of skin blood content Peng, Yu-Hao Maarek, Jean-Michel I. J Biomed Opt General SIGNIFICANCE: We present an approach to estimate with simple instrumentation the amount of red blood cells in the skin microvasculature, designated as parameter [Formula: see text]. Variations of parameter [Formula: see text] are shown to reflect local changes in the quantity of skin red blood cells during a venous occlusion challenge. AIM: To validate a simple algebraic model of light transport in skin using the Monte Carlo method and to develop a measure of the red blood cell content in skin microvessels using the Monte Carlo predictions; to guide the development of an instrument to measure experimentally variations of the amount of red blood cells in the skin. APPROACH: Monte Carlo simulations were carried out in a multilayer model of the skin to compute remitted light intensities as a function of distance from the illumination locus for different values of the skin blood content. The simulation results were used to compute parameter [Formula: see text] and its variations with local skin blood content. An experimental setup was developed to measure parameter [Formula: see text] in human volunteers in whom skin blood content of the forearm increased during temporary interruption of the venous outflow. RESULTS: In the simulations, parameter [Formula: see text] was [Formula: see text] in baseline conditions, and it increased in near proportion with the blood content of the skin layers. Measuring the diffusely reflected light intensity 0.5 to 1.2 mm away from the illumination locus was optimal to detect appreciable changes of the reflected light intensity as skin blood content was altered. Parameter [Formula: see text] measured experimentally on the human forearm was [Formula: see text] in baseline conditions it increased at a rate of [Formula: see text] when venous outflow was temporarily interrupted. CONCLUSION: Parameter [Formula: see text] derived experimentally with a two-wavelength diffuse reflectometer can be used to measure local variations of the amount of red blood cells in skin microvessels. Society of Photo-Optical Instrumentation Engineers 2022-06-30 2022-06 /pmc/articles/PMC9243648/ /pubmed/35773754 http://dx.doi.org/10.1117/1.JBO.27.6.065003 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle General
Peng, Yu-Hao
Maarek, Jean-Michel I.
Development and validation of quantitative optical index of skin blood content
title Development and validation of quantitative optical index of skin blood content
title_full Development and validation of quantitative optical index of skin blood content
title_fullStr Development and validation of quantitative optical index of skin blood content
title_full_unstemmed Development and validation of quantitative optical index of skin blood content
title_short Development and validation of quantitative optical index of skin blood content
title_sort development and validation of quantitative optical index of skin blood content
topic General
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9243648/
https://www.ncbi.nlm.nih.gov/pubmed/35773754
http://dx.doi.org/10.1117/1.JBO.27.6.065003
work_keys_str_mv AT pengyuhao developmentandvalidationofquantitativeopticalindexofskinbloodcontent
AT maarekjeanmicheli developmentandvalidationofquantitativeopticalindexofskinbloodcontent