Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study

OBJECTIVE: To determine the diagnostic accuracy of three tests—radial pulse palpation, an electronic blood pressure monitor and a handheld single-lead ECG device—for opportunistic screening for unknown atrial fibrillation (AF). DESIGN: We performed a diagnostic accuracy study in the intention-to-scr...

Descripción completa

Detalles Bibliográficos
Autores principales: Verbiest-van Gurp, Nicole, Uittenbogaart, Steven B, Lucassen, Wim A M, Erkens, Petra M G, Knottnerus, J André, Winkens, Bjorn, Stoffers, Henri E J H, van Weert, Henk C P M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9244719/
https://www.ncbi.nlm.nih.gov/pubmed/35768092
http://dx.doi.org/10.1136/bmjopen-2021-059172
_version_ 1784738591260278784
author Verbiest-van Gurp, Nicole
Uittenbogaart, Steven B
Lucassen, Wim A M
Erkens, Petra M G
Knottnerus, J André
Winkens, Bjorn
Stoffers, Henri E J H
van Weert, Henk C P M
author_facet Verbiest-van Gurp, Nicole
Uittenbogaart, Steven B
Lucassen, Wim A M
Erkens, Petra M G
Knottnerus, J André
Winkens, Bjorn
Stoffers, Henri E J H
van Weert, Henk C P M
author_sort Verbiest-van Gurp, Nicole
collection PubMed
description OBJECTIVE: To determine the diagnostic accuracy of three tests—radial pulse palpation, an electronic blood pressure monitor and a handheld single-lead ECG device—for opportunistic screening for unknown atrial fibrillation (AF). DESIGN: We performed a diagnostic accuracy study in the intention-to-screen arm of a cluster randomised controlled trial aimed at opportunistic screening for AF in general practice. We performed radial pulse palpation, followed by electronic blood pressure measurement (WatchBP Home A) and handheld ECG (MyDiagnostick) in random order. If one or more index tests were positive, we performed a 12-lead ECG at shortest notice. Similarly, to limit verification bias, a random sample of patients with three negative index tests received this reference test. Additionally, we analysed the dataset using multiple imputation. We present pooled diagnostic parameters. SETTING: 47 general practices participated between September 2015 and August 2018. PARTICIPANTS: In the electronic medical record system of the participating general practices (n=47), we randomly marked 200 patients of ≥65 years without AF. When they visited the practice for any reason, we invited them to participate. Exclusion criteria were terminal illness, inability to give informed consent or visit the practice or having a pacemaker or an implantable cardioverter-defibrillator. OUTCOMES: Diagnostic accuracy of individual tests and test combinations to detect unknown AF. RESULTS: We included 4339 patients; 0.8% showed new AF. Sensitivity and specificity were 62.8% (range 43.1%–69.7%) and 91.8% (91.7%–91.8%) for radial pulse palpation, 70.0% (49.0%–80.6%) and 96.5% (96.3%–96.7%) for electronic blood pressure measurement and 90.1% (60.8%–100%) and 97.9% (97.8%–97.9%) for handheld ECG, respectively. Positive predictive values were 5.8% (5.3%–6.1%), 13.8% (12.2%–14.8%) and 25.2% (24.2%–25.8%), respectively. All negative predictive values were ≥99.7%. CONCLUSION: In detecting AF, electronic blood pressure measurement (WatchBP Home A), but especially handheld ECG (MyDiagnostick) showed better diagnostic accuracy than radial pulse palpation. TRIAL REGISTRATION NUMBER: Netherlands Trial Register No. NL4776 (old NTR4914).
format Online
Article
Text
id pubmed-9244719
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-92447192022-07-14 Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study Verbiest-van Gurp, Nicole Uittenbogaart, Steven B Lucassen, Wim A M Erkens, Petra M G Knottnerus, J André Winkens, Bjorn Stoffers, Henri E J H van Weert, Henk C P M BMJ Open Diagnostics OBJECTIVE: To determine the diagnostic accuracy of three tests—radial pulse palpation, an electronic blood pressure monitor and a handheld single-lead ECG device—for opportunistic screening for unknown atrial fibrillation (AF). DESIGN: We performed a diagnostic accuracy study in the intention-to-screen arm of a cluster randomised controlled trial aimed at opportunistic screening for AF in general practice. We performed radial pulse palpation, followed by electronic blood pressure measurement (WatchBP Home A) and handheld ECG (MyDiagnostick) in random order. If one or more index tests were positive, we performed a 12-lead ECG at shortest notice. Similarly, to limit verification bias, a random sample of patients with three negative index tests received this reference test. Additionally, we analysed the dataset using multiple imputation. We present pooled diagnostic parameters. SETTING: 47 general practices participated between September 2015 and August 2018. PARTICIPANTS: In the electronic medical record system of the participating general practices (n=47), we randomly marked 200 patients of ≥65 years without AF. When they visited the practice for any reason, we invited them to participate. Exclusion criteria were terminal illness, inability to give informed consent or visit the practice or having a pacemaker or an implantable cardioverter-defibrillator. OUTCOMES: Diagnostic accuracy of individual tests and test combinations to detect unknown AF. RESULTS: We included 4339 patients; 0.8% showed new AF. Sensitivity and specificity were 62.8% (range 43.1%–69.7%) and 91.8% (91.7%–91.8%) for radial pulse palpation, 70.0% (49.0%–80.6%) and 96.5% (96.3%–96.7%) for electronic blood pressure measurement and 90.1% (60.8%–100%) and 97.9% (97.8%–97.9%) for handheld ECG, respectively. Positive predictive values were 5.8% (5.3%–6.1%), 13.8% (12.2%–14.8%) and 25.2% (24.2%–25.8%), respectively. All negative predictive values were ≥99.7%. CONCLUSION: In detecting AF, electronic blood pressure measurement (WatchBP Home A), but especially handheld ECG (MyDiagnostick) showed better diagnostic accuracy than radial pulse palpation. TRIAL REGISTRATION NUMBER: Netherlands Trial Register No. NL4776 (old NTR4914). BMJ Publishing Group 2022-06-29 /pmc/articles/PMC9244719/ /pubmed/35768092 http://dx.doi.org/10.1136/bmjopen-2021-059172 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Diagnostics
Verbiest-van Gurp, Nicole
Uittenbogaart, Steven B
Lucassen, Wim A M
Erkens, Petra M G
Knottnerus, J André
Winkens, Bjorn
Stoffers, Henri E J H
van Weert, Henk C P M
Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study
title Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study
title_full Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study
title_fullStr Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study
title_full_unstemmed Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study
title_short Detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study
title_sort detection of atrial fibrillation in primary care with radial pulse palpation, electronic blood pressure measurement and handheld single-lead electrocardiography: a diagnostic accuracy study
topic Diagnostics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9244719/
https://www.ncbi.nlm.nih.gov/pubmed/35768092
http://dx.doi.org/10.1136/bmjopen-2021-059172
work_keys_str_mv AT verbiestvangurpnicole detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy
AT uittenbogaartstevenb detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy
AT lucassenwimam detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy
AT erkenspetramg detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy
AT knottnerusjandre detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy
AT winkensbjorn detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy
AT stoffershenriejh detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy
AT vanweerthenkcpm detectionofatrialfibrillationinprimarycarewithradialpulsepalpationelectronicbloodpressuremeasurementandhandheldsingleleadelectrocardiographyadiagnosticaccuracystudy