Cargando…

Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia

The aim is to solve the problem of the urgent need of a nonradiation, noninvasive, and simple-to-operate diagnostic method for neonatal pneumonia that can indicate the severity of the disease and dynamically monitor the outcome of the disease. The authors propose a bedside high-frequency ultrasound...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Jianchang, Chen, Peng, Jiang, Dazhi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9246586/
https://www.ncbi.nlm.nih.gov/pubmed/35833070
http://dx.doi.org/10.1155/2022/4805300
_version_ 1784738998075260928
author Zhu, Jianchang
Chen, Peng
Jiang, Dazhi
author_facet Zhu, Jianchang
Chen, Peng
Jiang, Dazhi
author_sort Zhu, Jianchang
collection PubMed
description The aim is to solve the problem of the urgent need of a nonradiation, noninvasive, and simple-to-operate diagnostic method for neonatal pneumonia that can indicate the severity of the disease and dynamically monitor the outcome of the disease. The authors propose a bedside high-frequency ultrasound technique based on methods for evaluation in the detection and treatment of neonatal pneumonia. The results obtained are as follows: the sensitivity of neonatal lung ultrasound in the diagnosis of neonatal pneumonia was 96.6%, the specificity was 93.3%, the positive predictive value was 93.5%, and the negative predictive value was 96.5%. The sensitivity of chest X-ray in the diagnosis of neonatal pneumonia was 93.3%. Compared with the lung ultrasound and chest X-ray in the diagnosis of neonatal pneumonia, the two had a good correlation. The neonatal respiratory score was positively correlated with the lung ultrasound score, and the higher the lung ultrasound score, the more severe the disease. The score decreased by 35% after 3 days of treatment and 68% after 7 days of treatment, indicating that the lung high-frequency ultrasound score can be very effective in characterizing the treatment situation. It has been demonstrated that the lung ultrasound can be used as an imaging method for the diagnosis of neonatal pneumonia. The higher the lung ultrasound score, the more severe the disease, and the lung ultrasound score was positively correlated with the disease severity. With dynamic monitoring of the lung ultrasound and the gradual improvement of clinical symptoms after treatment, the lung ultrasound score gradually decreased; therefore, the lung ultrasound can be used for re-examination of neonatal pneumonia to evaluate the treatment effect and guidance.
format Online
Article
Text
id pubmed-9246586
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-92465862022-07-12 Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia Zhu, Jianchang Chen, Peng Jiang, Dazhi Contrast Media Mol Imaging Research Article The aim is to solve the problem of the urgent need of a nonradiation, noninvasive, and simple-to-operate diagnostic method for neonatal pneumonia that can indicate the severity of the disease and dynamically monitor the outcome of the disease. The authors propose a bedside high-frequency ultrasound technique based on methods for evaluation in the detection and treatment of neonatal pneumonia. The results obtained are as follows: the sensitivity of neonatal lung ultrasound in the diagnosis of neonatal pneumonia was 96.6%, the specificity was 93.3%, the positive predictive value was 93.5%, and the negative predictive value was 96.5%. The sensitivity of chest X-ray in the diagnosis of neonatal pneumonia was 93.3%. Compared with the lung ultrasound and chest X-ray in the diagnosis of neonatal pneumonia, the two had a good correlation. The neonatal respiratory score was positively correlated with the lung ultrasound score, and the higher the lung ultrasound score, the more severe the disease. The score decreased by 35% after 3 days of treatment and 68% after 7 days of treatment, indicating that the lung high-frequency ultrasound score can be very effective in characterizing the treatment situation. It has been demonstrated that the lung ultrasound can be used as an imaging method for the diagnosis of neonatal pneumonia. The higher the lung ultrasound score, the more severe the disease, and the lung ultrasound score was positively correlated with the disease severity. With dynamic monitoring of the lung ultrasound and the gradual improvement of clinical symptoms after treatment, the lung ultrasound score gradually decreased; therefore, the lung ultrasound can be used for re-examination of neonatal pneumonia to evaluate the treatment effect and guidance. Hindawi 2022-06-23 /pmc/articles/PMC9246586/ /pubmed/35833070 http://dx.doi.org/10.1155/2022/4805300 Text en Copyright © 2022 Jianchang Zhu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhu, Jianchang
Chen, Peng
Jiang, Dazhi
Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia
title Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia
title_full Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia
title_fullStr Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia
title_full_unstemmed Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia
title_short Clinical Value and Imaging Features of Bedside High-Frequency Ultrasound Imaging in the Diagnosis of Neonatal Pneumonia
title_sort clinical value and imaging features of bedside high-frequency ultrasound imaging in the diagnosis of neonatal pneumonia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9246586/
https://www.ncbi.nlm.nih.gov/pubmed/35833070
http://dx.doi.org/10.1155/2022/4805300
work_keys_str_mv AT zhujianchang clinicalvalueandimagingfeaturesofbedsidehighfrequencyultrasoundimaginginthediagnosisofneonatalpneumonia
AT chenpeng clinicalvalueandimagingfeaturesofbedsidehighfrequencyultrasoundimaginginthediagnosisofneonatalpneumonia
AT jiangdazhi clinicalvalueandimagingfeaturesofbedsidehighfrequencyultrasoundimaginginthediagnosisofneonatalpneumonia