Cargando…
The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes
PURPOSE: To evaluate the influence of corneal ablation patterns on the prediction error after cataract surgery in post-myopic-LASIK eyes. METHODS: Eighty-three post-myopic-LASIK eyes of 83 patients that underwent uneventful cataract surgery were retrospectively included. Predicted postoperative sphe...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9248133/ https://www.ncbi.nlm.nih.gov/pubmed/35773703 http://dx.doi.org/10.1186/s40662-022-00295-1 |
_version_ | 1784739307279351808 |
---|---|
author | Yao, Yunqian Zhao, Jing Yu, Jifeng He, Wenwen Wei, Ling Zhou, Xingtao Lu, Yi Zhu, Xiangjia |
author_facet | Yao, Yunqian Zhao, Jing Yu, Jifeng He, Wenwen Wei, Ling Zhou, Xingtao Lu, Yi Zhu, Xiangjia |
author_sort | Yao, Yunqian |
collection | PubMed |
description | PURPOSE: To evaluate the influence of corneal ablation patterns on the prediction error after cataract surgery in post-myopic-LASIK eyes. METHODS: Eighty-three post-myopic-LASIK eyes of 83 patients that underwent uneventful cataract surgery were retrospectively included. Predicted postoperative spherical equivalence (SE) was calculated for the implanted lens using the Haigis-L and Barrett True-K formula. Prediction error at one month postsurgery was calculated as actual SE minus predicted SE. For each eye, area and decentration of the ablation zone was measured using the tangential curvature map. The associations between prediction errors and corneal ablation patterns were investigated. RESULTS: The mean prediction error was − 0.83 ± 1.00 D with the Haigis-L formula and − 1.00 ± 0.99 D with the Barrett True-K formula. Prediction error was positively correlated with keratometry (K) value and negatively correlated with ablation zone area using either formula, and negatively correlated with decentration of the ablation zone using the Barrett True-K formula (all P < 0.05). In the K < 37.08 D group, prediction error was negatively correlated with decentration of the ablation zone with both formulas (all P < 0.05). Multivariate analysis showed that with the Haigis-L formula, prediction error was associated with axial length (AL), K value and decentration, and with the Barrett True-K formula, prediction error was associated with AL and decentration (all P < 0.05). CONCLUSION: A flatter cornea, larger corneal ablation zone and greater decentration will lead to more myopic prediction error after cataract surgery in post-myopic-LASIK eyes. |
format | Online Article Text |
id | pubmed-9248133 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92481332022-07-02 The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes Yao, Yunqian Zhao, Jing Yu, Jifeng He, Wenwen Wei, Ling Zhou, Xingtao Lu, Yi Zhu, Xiangjia Eye Vis (Lond) Research PURPOSE: To evaluate the influence of corneal ablation patterns on the prediction error after cataract surgery in post-myopic-LASIK eyes. METHODS: Eighty-three post-myopic-LASIK eyes of 83 patients that underwent uneventful cataract surgery were retrospectively included. Predicted postoperative spherical equivalence (SE) was calculated for the implanted lens using the Haigis-L and Barrett True-K formula. Prediction error at one month postsurgery was calculated as actual SE minus predicted SE. For each eye, area and decentration of the ablation zone was measured using the tangential curvature map. The associations between prediction errors and corneal ablation patterns were investigated. RESULTS: The mean prediction error was − 0.83 ± 1.00 D with the Haigis-L formula and − 1.00 ± 0.99 D with the Barrett True-K formula. Prediction error was positively correlated with keratometry (K) value and negatively correlated with ablation zone area using either formula, and negatively correlated with decentration of the ablation zone using the Barrett True-K formula (all P < 0.05). In the K < 37.08 D group, prediction error was negatively correlated with decentration of the ablation zone with both formulas (all P < 0.05). Multivariate analysis showed that with the Haigis-L formula, prediction error was associated with axial length (AL), K value and decentration, and with the Barrett True-K formula, prediction error was associated with AL and decentration (all P < 0.05). CONCLUSION: A flatter cornea, larger corneal ablation zone and greater decentration will lead to more myopic prediction error after cataract surgery in post-myopic-LASIK eyes. BioMed Central 2022-07-01 /pmc/articles/PMC9248133/ /pubmed/35773703 http://dx.doi.org/10.1186/s40662-022-00295-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yao, Yunqian Zhao, Jing Yu, Jifeng He, Wenwen Wei, Ling Zhou, Xingtao Lu, Yi Zhu, Xiangjia The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes |
title | The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes |
title_full | The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes |
title_fullStr | The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes |
title_full_unstemmed | The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes |
title_short | The influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-LASIK eyes |
title_sort | influence of corneal ablation patterns on prediction error after cataract surgery in post-myopic-lasik eyes |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9248133/ https://www.ncbi.nlm.nih.gov/pubmed/35773703 http://dx.doi.org/10.1186/s40662-022-00295-1 |
work_keys_str_mv | AT yaoyunqian theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT zhaojing theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT yujifeng theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT hewenwen theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT weiling theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT zhouxingtao theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT luyi theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT zhuxiangjia theinfluenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT yaoyunqian influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT zhaojing influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT yujifeng influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT hewenwen influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT weiling influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT zhouxingtao influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT luyi influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes AT zhuxiangjia influenceofcornealablationpatternsonpredictionerroraftercataractsurgeryinpostmyopiclasikeyes |