Cargando…
Encouraging early outcomes with image guided pencil beam proton therapy for cranio-spinal irradiation: first report from India
BACKGROUND: To report our experience with image guided pencil beam proton beam therapy (PBT) for craniospinal irradiation (CSI). MATERIALS AND METHODS: Between January 2019 and December 2021, we carried out a detailed audit of the first forty patients treated with PBT. We had recorded acute toxiciti...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9248189/ https://www.ncbi.nlm.nih.gov/pubmed/35773667 http://dx.doi.org/10.1186/s13014-022-02085-4 |
Sumario: | BACKGROUND: To report our experience with image guided pencil beam proton beam therapy (PBT) for craniospinal irradiation (CSI). MATERIALS AND METHODS: Between January 2019 and December 2021, we carried out a detailed audit of the first forty patients treated with PBT. We had recorded acute toxicities, reporting early outcomes and discuss limitations of current contouring guidelines during CSI PBT planning. RESULTS: Median age of the patient cohort was 8 years, and histologies include 20 medulloblastoma, 7 recurrent ependymoma, 3 pineoblastoma, 3 were germ cell tumors and remaining 7 constituted other diagnoses. Forty percent patients received concurrent chemotherapy. Median CSI dose was 23.4 Gy (Gray; range 21.6–35 Gy). Thirty-five patients (87.5%) completed their CSI without interruption, 5 required hospital admission. No patient had grade 2/ > weight loss during the treatment. Forty-five percent (18) developed grade 1 haematological toxicities and 20% (8) developed grade 2 or 3 toxicities; none had grade 4 toxicities. At median follow up of 12 months, 90% patients are alive of whom 88.9% are having local control. Special consideration with modification in standard contouring used at our institute helped in limiting acute toxicities in paediatric CSI patients. CONCLUSION: Our preliminary experience with modern contemporary PBT using pencil beam technology and daily image guidance in a range of tumours suitable for CSI is encouraging. Patients tolerated the treatment well with acceptable acute toxicity and expected short-term survival outcome. In paediatric CSI patients, modification in standard contouring guidelines required to achieve better results with PBT. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-022-02085-4. |
---|