Cargando…

Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography

OBJECTIVES: To evaluate the performance of convolutional neural network (CNN) architectures to distinguish eyes with glaucoma from normal eyes. MATERIALS AND METHODS: A total of 9,950 fundus photographs of 5,388 patients from the database of Eskişehir Osmangazi University Faculty of Medicine Ophthal...

Descripción completa

Detalles Bibliográficos
Autores principales: Atalay, Eray, Özalp, Onur, Devecioğlu, Özer Can, Erdoğan, Hakika, İnce, Türker, Yıldırım, Nilgün
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249112/
https://www.ncbi.nlm.nih.gov/pubmed/35770344
http://dx.doi.org/10.4274/tjo.galenos.2021.29726
_version_ 1784739502946779136
author Atalay, Eray
Özalp, Onur
Devecioğlu, Özer Can
Erdoğan, Hakika
İnce, Türker
Yıldırım, Nilgün
author_facet Atalay, Eray
Özalp, Onur
Devecioğlu, Özer Can
Erdoğan, Hakika
İnce, Türker
Yıldırım, Nilgün
author_sort Atalay, Eray
collection PubMed
description OBJECTIVES: To evaluate the performance of convolutional neural network (CNN) architectures to distinguish eyes with glaucoma from normal eyes. MATERIALS AND METHODS: A total of 9,950 fundus photographs of 5,388 patients from the database of Eskişehir Osmangazi University Faculty of Medicine Ophthalmology Clinic were labelled as glaucoma, glaucoma suspect, or normal by three different experienced ophthalmologists. The categorized fundus photographs were evaluated using a state-of-the-art two-dimensional CNN and compared with deep residual networks (ResNet) and very deep neural networks (VGG). The accuracy, sensitivity, and specificity of glaucoma detection with the different algorithms were evaluated using a dataset of 238 normal and 320 glaucomatous fundus photographs. For the detection of suspected glaucoma, ResNet-101 architectures were tested with a data set of 170 normal, 170 glaucoma, and 167 glaucoma-suspect fundus photographs. RESULTS: Accuracy, sensitivity, and specificity in detecting glaucoma were 96.2%, 99.5%, and 93.7% with ResNet-50; 97.4%, 97.8%, and 97.1% with ResNet-101; 98.9%, 100%, and 98.1% with VGG-19, and 99.4%, 100%, and 99% with the 2D CNN, respectively. Accuracy, sensitivity, and specificity values in distinguishing glaucoma suspects from normal eyes were 62%, 68%, and 56% and those for differentiating glaucoma from suspected glaucoma were 92%, 81%, and 97%, respectively. While 55 photographs could be evaluated in 2 seconds with CNN, a clinician spent an average of 24.2 seconds to evaluate a single photograph. CONCLUSION: An appropriately designed and trained CNN was able to distinguish glaucoma with high accuracy even with a small number of fundus photographs.
format Online
Article
Text
id pubmed-9249112
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-92491122022-07-14 Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography Atalay, Eray Özalp, Onur Devecioğlu, Özer Can Erdoğan, Hakika İnce, Türker Yıldırım, Nilgün Turk J Ophthalmol Original Article OBJECTIVES: To evaluate the performance of convolutional neural network (CNN) architectures to distinguish eyes with glaucoma from normal eyes. MATERIALS AND METHODS: A total of 9,950 fundus photographs of 5,388 patients from the database of Eskişehir Osmangazi University Faculty of Medicine Ophthalmology Clinic were labelled as glaucoma, glaucoma suspect, or normal by three different experienced ophthalmologists. The categorized fundus photographs were evaluated using a state-of-the-art two-dimensional CNN and compared with deep residual networks (ResNet) and very deep neural networks (VGG). The accuracy, sensitivity, and specificity of glaucoma detection with the different algorithms were evaluated using a dataset of 238 normal and 320 glaucomatous fundus photographs. For the detection of suspected glaucoma, ResNet-101 architectures were tested with a data set of 170 normal, 170 glaucoma, and 167 glaucoma-suspect fundus photographs. RESULTS: Accuracy, sensitivity, and specificity in detecting glaucoma were 96.2%, 99.5%, and 93.7% with ResNet-50; 97.4%, 97.8%, and 97.1% with ResNet-101; 98.9%, 100%, and 98.1% with VGG-19, and 99.4%, 100%, and 99% with the 2D CNN, respectively. Accuracy, sensitivity, and specificity values in distinguishing glaucoma suspects from normal eyes were 62%, 68%, and 56% and those for differentiating glaucoma from suspected glaucoma were 92%, 81%, and 97%, respectively. While 55 photographs could be evaluated in 2 seconds with CNN, a clinician spent an average of 24.2 seconds to evaluate a single photograph. CONCLUSION: An appropriately designed and trained CNN was able to distinguish glaucoma with high accuracy even with a small number of fundus photographs. Galenos Publishing 2022-06 2022-06-29 /pmc/articles/PMC9249112/ /pubmed/35770344 http://dx.doi.org/10.4274/tjo.galenos.2021.29726 Text en © Copyright 2022 by Turkish Ophthalmological Association | Turkish Journal of Ophthalmology, published by Galenos Publishing House. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Atalay, Eray
Özalp, Onur
Devecioğlu, Özer Can
Erdoğan, Hakika
İnce, Türker
Yıldırım, Nilgün
Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography
title Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography
title_full Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography
title_fullStr Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography
title_full_unstemmed Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography
title_short Investigation of the Role of Convolutional Neural Network Architectures in the Diagnosis of Glaucoma using Color Fundus Photography
title_sort investigation of the role of convolutional neural network architectures in the diagnosis of glaucoma using color fundus photography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249112/
https://www.ncbi.nlm.nih.gov/pubmed/35770344
http://dx.doi.org/10.4274/tjo.galenos.2021.29726
work_keys_str_mv AT atalayeray investigationoftheroleofconvolutionalneuralnetworkarchitecturesinthediagnosisofglaucomausingcolorfundusphotography
AT ozalponur investigationoftheroleofconvolutionalneuralnetworkarchitecturesinthediagnosisofglaucomausingcolorfundusphotography
AT deveciogluozercan investigationoftheroleofconvolutionalneuralnetworkarchitecturesinthediagnosisofglaucomausingcolorfundusphotography
AT erdoganhakika investigationoftheroleofconvolutionalneuralnetworkarchitecturesinthediagnosisofglaucomausingcolorfundusphotography
AT inceturker investigationoftheroleofconvolutionalneuralnetworkarchitecturesinthediagnosisofglaucomausingcolorfundusphotography
AT yıldırımnilgun investigationoftheroleofconvolutionalneuralnetworkarchitecturesinthediagnosisofglaucomausingcolorfundusphotography