Cargando…

Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats

Arterial thromboembolism is associated with high morbidity and mortality rates in cats. Definitive diagnosis requires advanced imaging modalities, such as computed tomography angiography (CTA) and contrast-enhanced (CE) magnetic resonance angiography (MRA). However, CTA involves exposure to a large...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Minju, Ko, Minjung, Ahn, Jisoo, Ahn, Jiyoung, Yu, Jin, Chang, Jinhwa, Oh, Sukhoon, Chang, Dongwoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249124/
https://www.ncbi.nlm.nih.gov/pubmed/35782562
http://dx.doi.org/10.3389/fvets.2022.819627
_version_ 1784739505557733376
author Lee, Minju
Ko, Minjung
Ahn, Jisoo
Ahn, Jiyoung
Yu, Jin
Chang, Jinhwa
Oh, Sukhoon
Chang, Dongwoo
author_facet Lee, Minju
Ko, Minjung
Ahn, Jisoo
Ahn, Jiyoung
Yu, Jin
Chang, Jinhwa
Oh, Sukhoon
Chang, Dongwoo
author_sort Lee, Minju
collection PubMed
description Arterial thromboembolism is associated with high morbidity and mortality rates in cats. Definitive diagnosis requires advanced imaging modalities, such as computed tomography angiography (CTA) and contrast-enhanced (CE) magnetic resonance angiography (MRA). However, CTA involves exposure to a large amount of ionized radiation, and CE-MRA can cause systemic nephrogenic fibrosis. Non-contrast-enhanced (NE) MRA can help accurately diagnose vascular lesions without such limitations. In this study, we evaluated the ability of NE-MRA using three-dimensional electrocardiograph-gated fast spin-echo (3D ECG-FSE) and 3D time-of-flight (3D TOF) imaging to visualize the aorta and external iliac arteries in clinically healthy cats and compared the results with those obtained using CE-MRA. All 11 cats underwent 3D ECG-FSE, 3D TOF, and CE-MRA sequences. Relative signal intensity (rSI) for quantitative image analysis and image quality scores (IQS) for qualitative image analysis were assessed; the rSI values based on the 3D TOF evaluations were significantly lower than those obtained using 3D ECG-FSE (aorta 3D TOF: 0.57 ± 0.06, aorta 3D ECG-FSE: 0.83 ± 0.06, P < 0.001; external iliac arteries 3D TOF: 0.45 ± 0.06, external iliac arteries 3D ECG-FSE:0.80 ± 0.05, P < 0.001) and similar to those obtained using CE-MRA (aorta: 0.58 ± 0.05, external iliac arteries: 0.57 ± 0.03). Moreover, IQS obtained using 3D TOF were significantly higher than those obtained using 3D ECG-FSE (aorta 3D TOF: 3.95 ± 0.15, aorta 3D ECG-FSE: 2.32 ± 0.60, P < 0.001; external iliac arteries 3D ECG-FSE: 3.98 ± 0.08, external iliac arteries 3D ECG-FSE: 2.23 ± 0.56, P < 0.001) and similar to those obtained using CE-MRA (aorta: 3.61 ± 0.41, external iliac arteries: 3.57 ± 0.41). Thus, 3D TOF is more suitable and produces consistent image quality for visualizing the aorta and external iliac arteries in clinically healthy cats and this will be of great help in the diagnosis of FATE.
format Online
Article
Text
id pubmed-9249124
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92491242022-07-02 Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats Lee, Minju Ko, Minjung Ahn, Jisoo Ahn, Jiyoung Yu, Jin Chang, Jinhwa Oh, Sukhoon Chang, Dongwoo Front Vet Sci Veterinary Science Arterial thromboembolism is associated with high morbidity and mortality rates in cats. Definitive diagnosis requires advanced imaging modalities, such as computed tomography angiography (CTA) and contrast-enhanced (CE) magnetic resonance angiography (MRA). However, CTA involves exposure to a large amount of ionized radiation, and CE-MRA can cause systemic nephrogenic fibrosis. Non-contrast-enhanced (NE) MRA can help accurately diagnose vascular lesions without such limitations. In this study, we evaluated the ability of NE-MRA using three-dimensional electrocardiograph-gated fast spin-echo (3D ECG-FSE) and 3D time-of-flight (3D TOF) imaging to visualize the aorta and external iliac arteries in clinically healthy cats and compared the results with those obtained using CE-MRA. All 11 cats underwent 3D ECG-FSE, 3D TOF, and CE-MRA sequences. Relative signal intensity (rSI) for quantitative image analysis and image quality scores (IQS) for qualitative image analysis were assessed; the rSI values based on the 3D TOF evaluations were significantly lower than those obtained using 3D ECG-FSE (aorta 3D TOF: 0.57 ± 0.06, aorta 3D ECG-FSE: 0.83 ± 0.06, P < 0.001; external iliac arteries 3D TOF: 0.45 ± 0.06, external iliac arteries 3D ECG-FSE:0.80 ± 0.05, P < 0.001) and similar to those obtained using CE-MRA (aorta: 0.58 ± 0.05, external iliac arteries: 0.57 ± 0.03). Moreover, IQS obtained using 3D TOF were significantly higher than those obtained using 3D ECG-FSE (aorta 3D TOF: 3.95 ± 0.15, aorta 3D ECG-FSE: 2.32 ± 0.60, P < 0.001; external iliac arteries 3D ECG-FSE: 3.98 ± 0.08, external iliac arteries 3D ECG-FSE: 2.23 ± 0.56, P < 0.001) and similar to those obtained using CE-MRA (aorta: 3.61 ± 0.41, external iliac arteries: 3.57 ± 0.41). Thus, 3D TOF is more suitable and produces consistent image quality for visualizing the aorta and external iliac arteries in clinically healthy cats and this will be of great help in the diagnosis of FATE. Frontiers Media S.A. 2022-06-09 /pmc/articles/PMC9249124/ /pubmed/35782562 http://dx.doi.org/10.3389/fvets.2022.819627 Text en Copyright © 2022 Lee, Ko, Ahn, Ahn, Yu, Chang, Oh and Chang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Lee, Minju
Ko, Minjung
Ahn, Jisoo
Ahn, Jiyoung
Yu, Jin
Chang, Jinhwa
Oh, Sukhoon
Chang, Dongwoo
Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
title Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
title_full Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
title_fullStr Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
title_full_unstemmed Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
title_short Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
title_sort evaluation of the abdominal aorta and external iliac arteries using three-dimensional time-of-flight, three dimensional electrocardiograph-gated fast spin-echo, and contrast-enhanced magnetic resonance angiography in clinically healthy cats
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249124/
https://www.ncbi.nlm.nih.gov/pubmed/35782562
http://dx.doi.org/10.3389/fvets.2022.819627
work_keys_str_mv AT leeminju evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats
AT kominjung evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats
AT ahnjisoo evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats
AT ahnjiyoung evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats
AT yujin evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats
AT changjinhwa evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats
AT ohsukhoon evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats
AT changdongwoo evaluationoftheabdominalaortaandexternaliliacarteriesusingthreedimensionaltimeofflightthreedimensionalelectrocardiographgatedfastspinechoandcontrastenhancedmagneticresonanceangiographyinclinicallyhealthycats