Cargando…

Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis

The study investigates the diagnostic efficacy of ultrasound combined with the molybdenum target mode in breast cancer staging and the relationship between blood flow parameters and the expression of insulin-like growth factor 1 (IGF-1) and factor 2 (IGF-2) and prognosis. A total of 96 patients admi...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Huiliao, Zhang, Guifan, Zhou, Haixian, Lin, Chunyang, Xu, Qun, Liu, Ruixing, Yu, Beibei, Zhou, Xiuping, Wang, Zhejin, Xu, Zhihua, Lin, Lejing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249492/
https://www.ncbi.nlm.nih.gov/pubmed/35845730
http://dx.doi.org/10.1155/2022/9198626
_version_ 1784739595442716672
author He, Huiliao
Zhang, Guifan
Zhou, Haixian
Lin, Chunyang
Xu, Qun
Liu, Ruixing
Yu, Beibei
Zhou, Xiuping
Wang, Zhejin
Xu, Zhihua
Lin, Lejing
author_facet He, Huiliao
Zhang, Guifan
Zhou, Haixian
Lin, Chunyang
Xu, Qun
Liu, Ruixing
Yu, Beibei
Zhou, Xiuping
Wang, Zhejin
Xu, Zhihua
Lin, Lejing
author_sort He, Huiliao
collection PubMed
description The study investigates the diagnostic efficacy of ultrasound combined with the molybdenum target mode in breast cancer staging and the relationship between blood flow parameters and the expression of insulin-like growth factor 1 (IGF-1) and factor 2 (IGF-2) and prognosis. A total of 96 patients admitted to hospital from January 2020 to January 2021 are included in the breast cancer group, and 58 patients admitted to our hospital during the same period are included in the control group, who are diagnosed with benign breast lesions. All patients receive clinicopathological diagnosis, ultrasound detection, and X-ray molybdenum detection. Ultrasound detection, molybdenum target detection, ultrasound combined with the molybdenum target detection mode, and clinicopathological diagnosis results are compared. B-ultrasound combined with the molybdenum target detection mode has high efficiency in diagnosing breast cancer and differentiating pathological stages. Besides, blood flow parameters of patients are closely related to IGF-1 and IGF-2, and IGF-1 and IGF-2 expressions are closely related to the prognosis of patients. Subsequent diagnosis of the disease degree of breast cancer patients can be carried out by ultrasound combined with the molybdenum target detection mode. In addition, the expression of IGF-1 and IGF-2 in patients can be monitored to improve the clinical diagnosis and treatment plan to improve the prognosis of patients, which has a high clinical application value and is worth promoting.
format Online
Article
Text
id pubmed-9249492
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-92494922022-07-14 Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis He, Huiliao Zhang, Guifan Zhou, Haixian Lin, Chunyang Xu, Qun Liu, Ruixing Yu, Beibei Zhou, Xiuping Wang, Zhejin Xu, Zhihua Lin, Lejing Contrast Media Mol Imaging Research Article The study investigates the diagnostic efficacy of ultrasound combined with the molybdenum target mode in breast cancer staging and the relationship between blood flow parameters and the expression of insulin-like growth factor 1 (IGF-1) and factor 2 (IGF-2) and prognosis. A total of 96 patients admitted to hospital from January 2020 to January 2021 are included in the breast cancer group, and 58 patients admitted to our hospital during the same period are included in the control group, who are diagnosed with benign breast lesions. All patients receive clinicopathological diagnosis, ultrasound detection, and X-ray molybdenum detection. Ultrasound detection, molybdenum target detection, ultrasound combined with the molybdenum target detection mode, and clinicopathological diagnosis results are compared. B-ultrasound combined with the molybdenum target detection mode has high efficiency in diagnosing breast cancer and differentiating pathological stages. Besides, blood flow parameters of patients are closely related to IGF-1 and IGF-2, and IGF-1 and IGF-2 expressions are closely related to the prognosis of patients. Subsequent diagnosis of the disease degree of breast cancer patients can be carried out by ultrasound combined with the molybdenum target detection mode. In addition, the expression of IGF-1 and IGF-2 in patients can be monitored to improve the clinical diagnosis and treatment plan to improve the prognosis of patients, which has a high clinical application value and is worth promoting. Hindawi 2022-06-24 /pmc/articles/PMC9249492/ /pubmed/35845730 http://dx.doi.org/10.1155/2022/9198626 Text en Copyright © 2022 Huiliao He et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
He, Huiliao
Zhang, Guifan
Zhou, Haixian
Lin, Chunyang
Xu, Qun
Liu, Ruixing
Yu, Beibei
Zhou, Xiuping
Wang, Zhejin
Xu, Zhihua
Lin, Lejing
Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis
title Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis
title_full Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis
title_fullStr Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis
title_full_unstemmed Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis
title_short Differential Efficacy of B-Ultrasound Combined with Molybdenum Target Detection Mode for Breast Cancer Staging and Correlation of Blood Flow Parameters with IGF-1 and IGF-2 Expression Level and Prognosis
title_sort differential efficacy of b-ultrasound combined with molybdenum target detection mode for breast cancer staging and correlation of blood flow parameters with igf-1 and igf-2 expression level and prognosis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249492/
https://www.ncbi.nlm.nih.gov/pubmed/35845730
http://dx.doi.org/10.1155/2022/9198626
work_keys_str_mv AT hehuiliao differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT zhangguifan differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT zhouhaixian differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT linchunyang differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT xuqun differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT liuruixing differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT yubeibei differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT zhouxiuping differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT wangzhejin differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT xuzhihua differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis
AT linlejing differentialefficacyofbultrasoundcombinedwithmolybdenumtargetdetectionmodeforbreastcancerstagingandcorrelationofbloodflowparameterswithigf1andigf2expressionlevelandprognosis