Cargando…
Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation
In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery ca...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249899/ https://www.ncbi.nlm.nih.gov/pubmed/35778523 http://dx.doi.org/10.1038/s41598-022-14988-z |
_version_ | 1784739690763517952 |
---|---|
author | Murata, Yutaka Imai, Takumi Takeda, Chikashi Mizota, Toshiyuki Kawamoto, Shuji |
author_facet | Murata, Yutaka Imai, Takumi Takeda, Chikashi Mizota, Toshiyuki Kawamoto, Shuji |
author_sort | Murata, Yutaka |
collection | PubMed |
description | In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery catheter (PAC-CCO). The FVS has improved accuracy due to an updated cardiac output algorithm, but the effect of this change on the accuracy of FVS-CCO in liver transplantation is unclear. In this study, we assessed agreement between fourth-generation FVS-CCO and PAC-CCO in 20 patients aged ≥ 20 years who underwent scheduled or emergency liver transplantation at Kyoto University Hospital from September 2019 to June 2021. Consent was obtained before surgery and data were recorded throughout the surgical period. Pearson correlation coefficient (r), Bland–Altman and 4-quadrant plot analyses were performed on the extracted data. A total of 1517 PAC-CCO vs. FVS-CCO data pairs were obtained. The mean PAC-CCO was 8.73 L/min and the mean systemic vascular resistance was 617.5 dyne·s·cm(-5), r was 0.48, bias was 1.62 L/min, the 95% limits of agreement were − 3.04 to 6.27, and the percentage error was 54.36%. These results show that agreement and trending between fourth-generation FVS-CCO and PAC-CCO are low in adult liver transplant recipients. |
format | Online Article Text |
id | pubmed-9249899 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-92498992022-07-03 Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation Murata, Yutaka Imai, Takumi Takeda, Chikashi Mizota, Toshiyuki Kawamoto, Shuji Sci Rep Article In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery catheter (PAC-CCO). The FVS has improved accuracy due to an updated cardiac output algorithm, but the effect of this change on the accuracy of FVS-CCO in liver transplantation is unclear. In this study, we assessed agreement between fourth-generation FVS-CCO and PAC-CCO in 20 patients aged ≥ 20 years who underwent scheduled or emergency liver transplantation at Kyoto University Hospital from September 2019 to June 2021. Consent was obtained before surgery and data were recorded throughout the surgical period. Pearson correlation coefficient (r), Bland–Altman and 4-quadrant plot analyses were performed on the extracted data. A total of 1517 PAC-CCO vs. FVS-CCO data pairs were obtained. The mean PAC-CCO was 8.73 L/min and the mean systemic vascular resistance was 617.5 dyne·s·cm(-5), r was 0.48, bias was 1.62 L/min, the 95% limits of agreement were − 3.04 to 6.27, and the percentage error was 54.36%. These results show that agreement and trending between fourth-generation FVS-CCO and PAC-CCO are low in adult liver transplant recipients. Nature Publishing Group UK 2022-07-01 /pmc/articles/PMC9249899/ /pubmed/35778523 http://dx.doi.org/10.1038/s41598-022-14988-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Murata, Yutaka Imai, Takumi Takeda, Chikashi Mizota, Toshiyuki Kawamoto, Shuji Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation |
title | Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation |
title_full | Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation |
title_fullStr | Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation |
title_full_unstemmed | Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation |
title_short | Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation |
title_sort | agreement between continuous cardiac output measured by the fourth-generation flotrac/vigileo system and a pulmonary artery catheter in adult liver transplantation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249899/ https://www.ncbi.nlm.nih.gov/pubmed/35778523 http://dx.doi.org/10.1038/s41598-022-14988-z |
work_keys_str_mv | AT muratayutaka agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation AT imaitakumi agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation AT takedachikashi agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation AT mizotatoshiyuki agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation AT kawamotoshuji agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation |