Cargando…

Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation

In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Murata, Yutaka, Imai, Takumi, Takeda, Chikashi, Mizota, Toshiyuki, Kawamoto, Shuji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249899/
https://www.ncbi.nlm.nih.gov/pubmed/35778523
http://dx.doi.org/10.1038/s41598-022-14988-z
_version_ 1784739690763517952
author Murata, Yutaka
Imai, Takumi
Takeda, Chikashi
Mizota, Toshiyuki
Kawamoto, Shuji
author_facet Murata, Yutaka
Imai, Takumi
Takeda, Chikashi
Mizota, Toshiyuki
Kawamoto, Shuji
author_sort Murata, Yutaka
collection PubMed
description In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery catheter (PAC-CCO). The FVS has improved accuracy due to an updated cardiac output algorithm, but the effect of this change on the accuracy of FVS-CCO in liver transplantation is unclear. In this study, we assessed agreement between fourth-generation FVS-CCO and PAC-CCO in 20 patients aged ≥ 20 years who underwent scheduled or emergency liver transplantation at Kyoto University Hospital from September 2019 to June 2021. Consent was obtained before surgery and data were recorded throughout the surgical period. Pearson correlation coefficient (r), Bland–Altman and 4-quadrant plot analyses were performed on the extracted data. A total of 1517 PAC-CCO vs. FVS-CCO data pairs were obtained. The mean PAC-CCO was 8.73 L/min and the mean systemic vascular resistance was 617.5 dyne·s·cm(-5), r was 0.48, bias was 1.62 L/min, the 95% limits of agreement were − 3.04 to 6.27, and the percentage error was 54.36%. These results show that agreement and trending between fourth-generation FVS-CCO and PAC-CCO are low in adult liver transplant recipients.
format Online
Article
Text
id pubmed-9249899
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-92498992022-07-03 Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation Murata, Yutaka Imai, Takumi Takeda, Chikashi Mizota, Toshiyuki Kawamoto, Shuji Sci Rep Article In liver transplantation for end-stage liver failure, monitoring of continuous cardiac output (CCO) is used for circulatory management due to hemodynamic instability. CCO is often measured using the minimally invasive FloTrac/Vigileo system (FVS-CCO), instead of a highly invasive pulmonary artery catheter (PAC-CCO). The FVS has improved accuracy due to an updated cardiac output algorithm, but the effect of this change on the accuracy of FVS-CCO in liver transplantation is unclear. In this study, we assessed agreement between fourth-generation FVS-CCO and PAC-CCO in 20 patients aged ≥ 20 years who underwent scheduled or emergency liver transplantation at Kyoto University Hospital from September 2019 to June 2021. Consent was obtained before surgery and data were recorded throughout the surgical period. Pearson correlation coefficient (r), Bland–Altman and 4-quadrant plot analyses were performed on the extracted data. A total of 1517 PAC-CCO vs. FVS-CCO data pairs were obtained. The mean PAC-CCO was 8.73 L/min and the mean systemic vascular resistance was 617.5 dyne·s·cm(-5), r was 0.48, bias was 1.62 L/min, the 95% limits of agreement were − 3.04 to 6.27, and the percentage error was 54.36%. These results show that agreement and trending between fourth-generation FVS-CCO and PAC-CCO are low in adult liver transplant recipients. Nature Publishing Group UK 2022-07-01 /pmc/articles/PMC9249899/ /pubmed/35778523 http://dx.doi.org/10.1038/s41598-022-14988-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Murata, Yutaka
Imai, Takumi
Takeda, Chikashi
Mizota, Toshiyuki
Kawamoto, Shuji
Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation
title Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation
title_full Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation
title_fullStr Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation
title_full_unstemmed Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation
title_short Agreement between continuous cardiac output measured by the fourth-generation FloTrac/Vigileo system and a pulmonary artery catheter in adult liver transplantation
title_sort agreement between continuous cardiac output measured by the fourth-generation flotrac/vigileo system and a pulmonary artery catheter in adult liver transplantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9249899/
https://www.ncbi.nlm.nih.gov/pubmed/35778523
http://dx.doi.org/10.1038/s41598-022-14988-z
work_keys_str_mv AT muratayutaka agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation
AT imaitakumi agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation
AT takedachikashi agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation
AT mizotatoshiyuki agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation
AT kawamotoshuji agreementbetweencontinuouscardiacoutputmeasuredbythefourthgenerationflotracvigileosystemandapulmonaryarterycatheterinadultlivertransplantation