Cargando…
Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer
Recently, several breast surgeons have reported a new method for sentinel lymph node biopsy (SLNB) by using indocyanine green (ICG) with infrared camera. This study aimed to determine whether the lymph nodes (LNs) with ICG uptake are true SLNs and to assess the reliability of using only ICG for SLNB...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Breast Cancer Society
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9250879/ https://www.ncbi.nlm.nih.gov/pubmed/35775703 http://dx.doi.org/10.4048/jbc.2022.25.e27 |
_version_ | 1784739904457015296 |
---|---|
author | Kang, Byeongju Lee, Jong Ho Lee, Jeeyeon Jung, Jin Hyang Kim, Wan Wook Chu, Gyoyeong Chae, Yeesoo Lee, Soo Jung Lee, In Hee Yang, Jung Dug Lee, Joon Seok Park, Ho Yong |
author_facet | Kang, Byeongju Lee, Jong Ho Lee, Jeeyeon Jung, Jin Hyang Kim, Wan Wook Chu, Gyoyeong Chae, Yeesoo Lee, Soo Jung Lee, In Hee Yang, Jung Dug Lee, Joon Seok Park, Ho Yong |
author_sort | Kang, Byeongju |
collection | PubMed |
description | Recently, several breast surgeons have reported a new method for sentinel lymph node biopsy (SLNB) by using indocyanine green (ICG) with infrared camera. This study aimed to determine whether the lymph nodes (LNs) with ICG uptake are true SLNs and to assess the reliability of using only ICG for SLNB. Data were prospectively collected between April and September 2021. All palpable LNs were fat-trimmed and ordered from high to low signal of the gamma detector. The degree of radioisotope uptake and brightness of ICG staining of the axillary LNs detected with a fluorescent camera were compared and associated factors were analyzed. Discordance was defined as sentinel LNs (SLNs) showing a single uptake of radioisotope or fluorescence of ICG only, or when the orders of uptake and intensity degree were different between the 2 materials. A total of 79 SLNBs were performed on 78 patients with breast cancer. The breast cancer was classified as cTis-2N0-1. The discordance rate was 14/79 (17.7%) overall and 45/270 (16.7%) of the total retrieved axillary LNs. The first SLNs showed the lowest discordance rate of 6.3%, whereas the second and third SLNs showed higher discordance rates of 27.6% and 60.0%, respectively. There were no associated clinicopathologic factors that affected the discordance between uptake of radioisotope and fluorescence intensity of ICG. The use of ICG alone for SLNB may be insufficient because of the high discordance rates between radioisotopes and ICG uptake. However, the first SLN could be cautiously regarded as a true SLN. |
format | Online Article Text |
id | pubmed-9250879 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Breast Cancer Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-92508792022-07-06 Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer Kang, Byeongju Lee, Jong Ho Lee, Jeeyeon Jung, Jin Hyang Kim, Wan Wook Chu, Gyoyeong Chae, Yeesoo Lee, Soo Jung Lee, In Hee Yang, Jung Dug Lee, Joon Seok Park, Ho Yong J Breast Cancer Brief Communication Recently, several breast surgeons have reported a new method for sentinel lymph node biopsy (SLNB) by using indocyanine green (ICG) with infrared camera. This study aimed to determine whether the lymph nodes (LNs) with ICG uptake are true SLNs and to assess the reliability of using only ICG for SLNB. Data were prospectively collected between April and September 2021. All palpable LNs were fat-trimmed and ordered from high to low signal of the gamma detector. The degree of radioisotope uptake and brightness of ICG staining of the axillary LNs detected with a fluorescent camera were compared and associated factors were analyzed. Discordance was defined as sentinel LNs (SLNs) showing a single uptake of radioisotope or fluorescence of ICG only, or when the orders of uptake and intensity degree were different between the 2 materials. A total of 79 SLNBs were performed on 78 patients with breast cancer. The breast cancer was classified as cTis-2N0-1. The discordance rate was 14/79 (17.7%) overall and 45/270 (16.7%) of the total retrieved axillary LNs. The first SLNs showed the lowest discordance rate of 6.3%, whereas the second and third SLNs showed higher discordance rates of 27.6% and 60.0%, respectively. There were no associated clinicopathologic factors that affected the discordance between uptake of radioisotope and fluorescence intensity of ICG. The use of ICG alone for SLNB may be insufficient because of the high discordance rates between radioisotopes and ICG uptake. However, the first SLN could be cautiously regarded as a true SLN. Korean Breast Cancer Society 2022-06-13 /pmc/articles/PMC9250879/ /pubmed/35775703 http://dx.doi.org/10.4048/jbc.2022.25.e27 Text en © 2022 Korean Breast Cancer Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Brief Communication Kang, Byeongju Lee, Jong Ho Lee, Jeeyeon Jung, Jin Hyang Kim, Wan Wook Chu, Gyoyeong Chae, Yeesoo Lee, Soo Jung Lee, In Hee Yang, Jung Dug Lee, Joon Seok Park, Ho Yong Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer |
title | Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer |
title_full | Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer |
title_fullStr | Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer |
title_full_unstemmed | Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer |
title_short | Comparative Study Between Radioisotope Uptake and Fluorescence Intensity of Indocyanine Green for Sentinel Lymph Node Biopsy in Breast Cancer |
title_sort | comparative study between radioisotope uptake and fluorescence intensity of indocyanine green for sentinel lymph node biopsy in breast cancer |
topic | Brief Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9250879/ https://www.ncbi.nlm.nih.gov/pubmed/35775703 http://dx.doi.org/10.4048/jbc.2022.25.e27 |
work_keys_str_mv | AT kangbyeongju comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT leejongho comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT leejeeyeon comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT jungjinhyang comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT kimwanwook comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT chugyoyeong comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT chaeyeesoo comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT leesoojung comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT leeinhee comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT yangjungdug comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT leejoonseok comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer AT parkhoyong comparativestudybetweenradioisotopeuptakeandfluorescenceintensityofindocyaninegreenforsentinellymphnodebiopsyinbreastcancer |