No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial

AIMS: Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using...

Descripción completa

Detalles Bibliográficos
Autores principales: Mills, Kelly, Wymenga, Ate B., van Hellemondt, Gijs G., Heesterbeek, Petra J. C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Editorial Society of Bone & Joint Surgery 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9251136/
https://www.ncbi.nlm.nih.gov/pubmed/35775183
http://dx.doi.org/10.1302/0301-620X.104B7.BJJ-2021-1600.R1
_version_ 1784739972774887424
author Mills, Kelly
Wymenga, Ate B.
van Hellemondt, Gijs G.
Heesterbeek, Petra J. C.
author_facet Mills, Kelly
Wymenga, Ate B.
van Hellemondt, Gijs G.
Heesterbeek, Petra J. C.
author_sort Mills, Kelly
collection PubMed
description AIMS: Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). METHODS: This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). RESULTS: The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. CONCLUSION: These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875–883.
format Online
Article
Text
id pubmed-9251136
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The British Editorial Society of Bone & Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-92511362022-07-07 No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial Mills, Kelly Wymenga, Ate B. van Hellemondt, Gijs G. Heesterbeek, Petra J. C. Bone Joint J Knee AIMS: Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). METHODS: This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). RESULTS: The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. CONCLUSION: These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875–883. The British Editorial Society of Bone & Joint Surgery 2022-07 2022-07-01 /pmc/articles/PMC9251136/ /pubmed/35775183 http://dx.doi.org/10.1302/0301-620X.104B7.BJJ-2021-1600.R1 Text en © 2022 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Knee
Mills, Kelly
Wymenga, Ate B.
van Hellemondt, Gijs G.
Heesterbeek, Petra J. C.
No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial
title No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial
title_full No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial
title_fullStr No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial
title_full_unstemmed No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial
title_short No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial
title_sort no difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9251136/
https://www.ncbi.nlm.nih.gov/pubmed/35775183
http://dx.doi.org/10.1302/0301-620X.104B7.BJJ-2021-1600.R1
work_keys_str_mv AT millskelly nodifferenceinlongtermmicromotionbetweenfullycementedandhybridfixationinrevisiontotalkneearthroplastyarandomizedcontrolledtrial
AT wymengaateb nodifferenceinlongtermmicromotionbetweenfullycementedandhybridfixationinrevisiontotalkneearthroplastyarandomizedcontrolledtrial
AT vanhellemondtgijsg nodifferenceinlongtermmicromotionbetweenfullycementedandhybridfixationinrevisiontotalkneearthroplastyarandomizedcontrolledtrial
AT heesterbeekpetrajc nodifferenceinlongtermmicromotionbetweenfullycementedandhybridfixationinrevisiontotalkneearthroplastyarandomizedcontrolledtrial