Cargando…

Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy

Objective: Hippocampus-sparing whole-brain radiotherapy using Halcyon, an instrument dedicated to volumetric modulated arc therapy, has not been studied till date; hence, we aimed to examine whether it can meet the RTOG0933 criteria. Based on this, we compared Halcyon to Tomotherapy, which also uses...

Descripción completa

Detalles Bibliográficos
Autores principales: Yokoyama, Kazutoshi, Kurosaki, Hiromasa, Oyoshi, Hajime, Miura, Kosei, Utsumi, Nobuko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9252014/
https://www.ncbi.nlm.nih.gov/pubmed/35770302
http://dx.doi.org/10.1177/15330338221108529
_version_ 1784740169511862272
author Yokoyama, Kazutoshi
Kurosaki, Hiromasa
Oyoshi, Hajime
Miura, Kosei
Utsumi, Nobuko
author_facet Yokoyama, Kazutoshi
Kurosaki, Hiromasa
Oyoshi, Hajime
Miura, Kosei
Utsumi, Nobuko
author_sort Yokoyama, Kazutoshi
collection PubMed
description Objective: Hippocampus-sparing whole-brain radiotherapy using Halcyon, an instrument dedicated to volumetric modulated arc therapy, has not been studied till date; hence, we aimed to examine whether it can meet the RTOG0933 criteria. Based on this, we compared Halcyon to Tomotherapy, which also uses an O-ring-type linear accelerator. Methods: This exploratory, experimental, and retrospective study used 5 sets of computed tomography images in the head area to investigate the planning target volume, hippocampal doses, and irradiation time. Calculations were performed from 1 to 4 arcs to determine the optimal number of arcs in the Halcyon plan, which were compared to those of Tomotherapy. Results: The Radiation Therapy Oncology Group 0933 criteria could not be satisfied in Halcyon with 1 arc. With 2 arcs, the condition D(max)<16 Gy was not satisfied for 1 case in the hippocampus. Since there were no significant differences between 3 and 4 arcs, including the irradiation time, 3 arcs were considered the best. We compared Halcyon at 3 arcs with tomotherapy and found that tomotherapy was inferior to Halcyon at D(98%); however, it was superior to Halcyon in other dose parameters. In contrast, the irradiation time in Halcyon was overwhelmingly superior, with the irradiation time for Halcyon being 1/ninth the time for Tomotherapy. Conclusion: Halcyon was effective in handling hippocampus-sparing whole-brain radiotherapy. We believe that 3-arc radiation is best suited for this procedure. Although Halcyon was inferior to Tomotherapy in terms of dose distribution excluding D(98%), it was overwhelmingly superior in terms of irradiation time.
format Online
Article
Text
id pubmed-9252014
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-92520142022-07-05 Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy Yokoyama, Kazutoshi Kurosaki, Hiromasa Oyoshi, Hajime Miura, Kosei Utsumi, Nobuko Technol Cancer Res Treat Original Article Objective: Hippocampus-sparing whole-brain radiotherapy using Halcyon, an instrument dedicated to volumetric modulated arc therapy, has not been studied till date; hence, we aimed to examine whether it can meet the RTOG0933 criteria. Based on this, we compared Halcyon to Tomotherapy, which also uses an O-ring-type linear accelerator. Methods: This exploratory, experimental, and retrospective study used 5 sets of computed tomography images in the head area to investigate the planning target volume, hippocampal doses, and irradiation time. Calculations were performed from 1 to 4 arcs to determine the optimal number of arcs in the Halcyon plan, which were compared to those of Tomotherapy. Results: The Radiation Therapy Oncology Group 0933 criteria could not be satisfied in Halcyon with 1 arc. With 2 arcs, the condition D(max)<16 Gy was not satisfied for 1 case in the hippocampus. Since there were no significant differences between 3 and 4 arcs, including the irradiation time, 3 arcs were considered the best. We compared Halcyon at 3 arcs with tomotherapy and found that tomotherapy was inferior to Halcyon at D(98%); however, it was superior to Halcyon in other dose parameters. In contrast, the irradiation time in Halcyon was overwhelmingly superior, with the irradiation time for Halcyon being 1/ninth the time for Tomotherapy. Conclusion: Halcyon was effective in handling hippocampus-sparing whole-brain radiotherapy. We believe that 3-arc radiation is best suited for this procedure. Although Halcyon was inferior to Tomotherapy in terms of dose distribution excluding D(98%), it was overwhelmingly superior in terms of irradiation time. SAGE Publications 2022-06-29 /pmc/articles/PMC9252014/ /pubmed/35770302 http://dx.doi.org/10.1177/15330338221108529 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Yokoyama, Kazutoshi
Kurosaki, Hiromasa
Oyoshi, Hajime
Miura, Kosei
Utsumi, Nobuko
Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy
title Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy
title_full Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy
title_fullStr Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy
title_full_unstemmed Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy
title_short Plan Quality Comparison Between Hippocampus-Sparing Whole-Brain Radiotherapy Treated With Halcyon and Tomotherapy Intensity-Modulated Radiotherapy
title_sort plan quality comparison between hippocampus-sparing whole-brain radiotherapy treated with halcyon and tomotherapy intensity-modulated radiotherapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9252014/
https://www.ncbi.nlm.nih.gov/pubmed/35770302
http://dx.doi.org/10.1177/15330338221108529
work_keys_str_mv AT yokoyamakazutoshi planqualitycomparisonbetweenhippocampussparingwholebrainradiotherapytreatedwithhalcyonandtomotherapyintensitymodulatedradiotherapy
AT kurosakihiromasa planqualitycomparisonbetweenhippocampussparingwholebrainradiotherapytreatedwithhalcyonandtomotherapyintensitymodulatedradiotherapy
AT oyoshihajime planqualitycomparisonbetweenhippocampussparingwholebrainradiotherapytreatedwithhalcyonandtomotherapyintensitymodulatedradiotherapy
AT miurakosei planqualitycomparisonbetweenhippocampussparingwholebrainradiotherapytreatedwithhalcyonandtomotherapyintensitymodulatedradiotherapy
AT utsuminobuko planqualitycomparisonbetweenhippocampussparingwholebrainradiotherapytreatedwithhalcyonandtomotherapyintensitymodulatedradiotherapy