Cargando…

A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study

BACKGROUND: Although peripherally inserted central catheters (PICCs) have been widely used, they have not been frequently used in anesthesia practice. The central venous pressure measured via PICCs are reportedly as accurate as that measured via central venous catheters (CVCs), but the findings conc...

Descripción completa

Detalles Bibliográficos
Autores principales: Maki, Jun, Sumie, Makoto, Ide, Tomoko, Nagamatsu, Masako, Matsushita, Katsuyuki, Shirozu, Kazuhiro, Higashi, Midoriko, Yamaura, Ken
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9252047/
https://www.ncbi.nlm.nih.gov/pubmed/35787789
http://dx.doi.org/10.1186/s12871-022-01738-x
_version_ 1784740176591847424
author Maki, Jun
Sumie, Makoto
Ide, Tomoko
Nagamatsu, Masako
Matsushita, Katsuyuki
Shirozu, Kazuhiro
Higashi, Midoriko
Yamaura, Ken
author_facet Maki, Jun
Sumie, Makoto
Ide, Tomoko
Nagamatsu, Masako
Matsushita, Katsuyuki
Shirozu, Kazuhiro
Higashi, Midoriko
Yamaura, Ken
author_sort Maki, Jun
collection PubMed
description BACKGROUND: Although peripherally inserted central catheters (PICCs) have been widely used, they have not been frequently used in anesthesia practice. The central venous pressure measured via PICCs are reportedly as accurate as that measured via central venous catheters (CVCs), but the findings concerning rapid infusion are unclear. This study examined whether or not pressure-resistant PICCs could be used for rapid fluid infusion.  METHODS: The in-line pressure was measured in similar-sized double-lumen catheters—4-Fr PICC (55, 45 and 35 cm) and 17-G CVC (20 and 13 cm)—at flow rates of saline decided using a roller pump system. We also examined the flow rate at an in-line pressure of 300 mmHg, which is the critical pressure at which hemolysis is considered to occur during blood transfusion. RESULTS: The pressure-resistant PICCs obtained a high flow rate similar to that of CVCs, but the in-line pressures increased in proportion to the flow rate and catheter length. Flow rates at an intra-circuit pressure of 300 mmHg were not significantly different between the 45-cm PICC and 20-cm CVC. CONCLUSION: Pressure-resistant PICCs can be used for rapid fluid infusion. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01738-x.
format Online
Article
Text
id pubmed-9252047
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-92520472022-07-05 A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study Maki, Jun Sumie, Makoto Ide, Tomoko Nagamatsu, Masako Matsushita, Katsuyuki Shirozu, Kazuhiro Higashi, Midoriko Yamaura, Ken BMC Anesthesiol Research Article BACKGROUND: Although peripherally inserted central catheters (PICCs) have been widely used, they have not been frequently used in anesthesia practice. The central venous pressure measured via PICCs are reportedly as accurate as that measured via central venous catheters (CVCs), but the findings concerning rapid infusion are unclear. This study examined whether or not pressure-resistant PICCs could be used for rapid fluid infusion.  METHODS: The in-line pressure was measured in similar-sized double-lumen catheters—4-Fr PICC (55, 45 and 35 cm) and 17-G CVC (20 and 13 cm)—at flow rates of saline decided using a roller pump system. We also examined the flow rate at an in-line pressure of 300 mmHg, which is the critical pressure at which hemolysis is considered to occur during blood transfusion. RESULTS: The pressure-resistant PICCs obtained a high flow rate similar to that of CVCs, but the in-line pressures increased in proportion to the flow rate and catheter length. Flow rates at an intra-circuit pressure of 300 mmHg were not significantly different between the 45-cm PICC and 20-cm CVC. CONCLUSION: Pressure-resistant PICCs can be used for rapid fluid infusion. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01738-x. BioMed Central 2022-07-04 /pmc/articles/PMC9252047/ /pubmed/35787789 http://dx.doi.org/10.1186/s12871-022-01738-x Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Maki, Jun
Sumie, Makoto
Ide, Tomoko
Nagamatsu, Masako
Matsushita, Katsuyuki
Shirozu, Kazuhiro
Higashi, Midoriko
Yamaura, Ken
A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
title A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
title_full A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
title_fullStr A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
title_full_unstemmed A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
title_short A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
title_sort pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9252047/
https://www.ncbi.nlm.nih.gov/pubmed/35787789
http://dx.doi.org/10.1186/s12871-022-01738-x
work_keys_str_mv AT makijun apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT sumiemakoto apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT idetomoko apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT nagamatsumasako apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT matsushitakatsuyuki apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT shirozukazuhiro apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT higashimidoriko apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT yamauraken apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT makijun pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT sumiemakoto pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT idetomoko pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT nagamatsumasako pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT matsushitakatsuyuki pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT shirozukazuhiro pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT higashimidoriko pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy
AT yamauraken pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy