Cargando…
A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study
BACKGROUND: Although peripherally inserted central catheters (PICCs) have been widely used, they have not been frequently used in anesthesia practice. The central venous pressure measured via PICCs are reportedly as accurate as that measured via central venous catheters (CVCs), but the findings conc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9252047/ https://www.ncbi.nlm.nih.gov/pubmed/35787789 http://dx.doi.org/10.1186/s12871-022-01738-x |
_version_ | 1784740176591847424 |
---|---|
author | Maki, Jun Sumie, Makoto Ide, Tomoko Nagamatsu, Masako Matsushita, Katsuyuki Shirozu, Kazuhiro Higashi, Midoriko Yamaura, Ken |
author_facet | Maki, Jun Sumie, Makoto Ide, Tomoko Nagamatsu, Masako Matsushita, Katsuyuki Shirozu, Kazuhiro Higashi, Midoriko Yamaura, Ken |
author_sort | Maki, Jun |
collection | PubMed |
description | BACKGROUND: Although peripherally inserted central catheters (PICCs) have been widely used, they have not been frequently used in anesthesia practice. The central venous pressure measured via PICCs are reportedly as accurate as that measured via central venous catheters (CVCs), but the findings concerning rapid infusion are unclear. This study examined whether or not pressure-resistant PICCs could be used for rapid fluid infusion. METHODS: The in-line pressure was measured in similar-sized double-lumen catheters—4-Fr PICC (55, 45 and 35 cm) and 17-G CVC (20 and 13 cm)—at flow rates of saline decided using a roller pump system. We also examined the flow rate at an in-line pressure of 300 mmHg, which is the critical pressure at which hemolysis is considered to occur during blood transfusion. RESULTS: The pressure-resistant PICCs obtained a high flow rate similar to that of CVCs, but the in-line pressures increased in proportion to the flow rate and catheter length. Flow rates at an intra-circuit pressure of 300 mmHg were not significantly different between the 45-cm PICC and 20-cm CVC. CONCLUSION: Pressure-resistant PICCs can be used for rapid fluid infusion. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01738-x. |
format | Online Article Text |
id | pubmed-9252047 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92520472022-07-05 A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study Maki, Jun Sumie, Makoto Ide, Tomoko Nagamatsu, Masako Matsushita, Katsuyuki Shirozu, Kazuhiro Higashi, Midoriko Yamaura, Ken BMC Anesthesiol Research Article BACKGROUND: Although peripherally inserted central catheters (PICCs) have been widely used, they have not been frequently used in anesthesia practice. The central venous pressure measured via PICCs are reportedly as accurate as that measured via central venous catheters (CVCs), but the findings concerning rapid infusion are unclear. This study examined whether or not pressure-resistant PICCs could be used for rapid fluid infusion. METHODS: The in-line pressure was measured in similar-sized double-lumen catheters—4-Fr PICC (55, 45 and 35 cm) and 17-G CVC (20 and 13 cm)—at flow rates of saline decided using a roller pump system. We also examined the flow rate at an in-line pressure of 300 mmHg, which is the critical pressure at which hemolysis is considered to occur during blood transfusion. RESULTS: The pressure-resistant PICCs obtained a high flow rate similar to that of CVCs, but the in-line pressures increased in proportion to the flow rate and catheter length. Flow rates at an intra-circuit pressure of 300 mmHg were not significantly different between the 45-cm PICC and 20-cm CVC. CONCLUSION: Pressure-resistant PICCs can be used for rapid fluid infusion. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01738-x. BioMed Central 2022-07-04 /pmc/articles/PMC9252047/ /pubmed/35787789 http://dx.doi.org/10.1186/s12871-022-01738-x Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Maki, Jun Sumie, Makoto Ide, Tomoko Nagamatsu, Masako Matsushita, Katsuyuki Shirozu, Kazuhiro Higashi, Midoriko Yamaura, Ken A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study |
title | A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study |
title_full | A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study |
title_fullStr | A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study |
title_full_unstemmed | A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study |
title_short | A pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study |
title_sort | pressure-resistant peripherally inserted central catheter is as useful as a central venous catheter for rapid fluid infusion: an in vitro study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9252047/ https://www.ncbi.nlm.nih.gov/pubmed/35787789 http://dx.doi.org/10.1186/s12871-022-01738-x |
work_keys_str_mv | AT makijun apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT sumiemakoto apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT idetomoko apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT nagamatsumasako apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT matsushitakatsuyuki apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT shirozukazuhiro apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT higashimidoriko apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT yamauraken apressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT makijun pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT sumiemakoto pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT idetomoko pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT nagamatsumasako pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT matsushitakatsuyuki pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT shirozukazuhiro pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT higashimidoriko pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy AT yamauraken pressureresistantperipherallyinsertedcentralcatheterisasusefulasacentralvenouscatheterforrapidfluidinfusionaninvitrostudy |