Cargando…

Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study

BACKGROUND: The pedicle screw system is widely used in spine surgery, and it provides rigid fixation and leads to successful subsequent deformity correction and bony fusion. The standard imaging technique for pedicle screw insertion is two-dimensional images obtained from C-arm-type X-ray fluoroscop...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsuoka, Akira, Toyone, Tomoaki, Okano, Ichiro, Kudo, Yoshifumi, Ishikawa, Koji, Maruyama, Hiroshi, Ozawa, Tomoyuki, Shirahata, Toshiyuki, Inagaki, Katsunori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9254419/
https://www.ncbi.nlm.nih.gov/pubmed/35790951
http://dx.doi.org/10.1186/s12891-022-05602-4
_version_ 1784740694832709632
author Matsuoka, Akira
Toyone, Tomoaki
Okano, Ichiro
Kudo, Yoshifumi
Ishikawa, Koji
Maruyama, Hiroshi
Ozawa, Tomoyuki
Shirahata, Toshiyuki
Inagaki, Katsunori
author_facet Matsuoka, Akira
Toyone, Tomoaki
Okano, Ichiro
Kudo, Yoshifumi
Ishikawa, Koji
Maruyama, Hiroshi
Ozawa, Tomoyuki
Shirahata, Toshiyuki
Inagaki, Katsunori
author_sort Matsuoka, Akira
collection PubMed
description BACKGROUND: The pedicle screw system is widely used in spine surgery, and it provides rigid fixation and leads to successful subsequent deformity correction and bony fusion. The standard imaging technique for pedicle screw insertion is two-dimensional images obtained from C-arm-type X-ray fluoroscopy. Artis Zeego is an emerging intraoperative imaging technique that can provide conventional two-dimensional fluoroscopic images and rapid three-dimensional fluoroscopic computed tomography reconstruction imaging. The aim of this study is to compare the insertion accuracies of PS placement using Artis Zeego and conventional 2D X-ray fluoroscopy. METHODS: In this study, we retrospectively reviewed the postoperative images of thoracolumbar fusion patients who underwent surgery using pedicle screws between 2013 and 2018. Pedicle screw malplacement was assessed using a four-grade classification by Rao et al. Misplacement rates were compared between pedicle screws assisted with Artis Zeego and two-dimensional fluoroscopy. RESULTS: A total of 1107 pedicle screws in 153 patients were inserted using Artis Zeego, and 427 pedicle screws in 80 patients were inserted using fluoroscopy. The overall perforation rate was 4.2% (46 perforations of 1106 pedicle screws) in the Artis Zeego group and 7.7% (33 perforations of 427 pedicle screws) in the fluoroscopy group. In the Artis Zeego group, 43 (3.9%) screws were classified as grade 1, and three (0.3%) screws were classified as grade 2. In the fluoroscopy group, 21 (4.9%) screws were classified as grade 1, 10 (2.3%) screws were classified as grade 2, and 2 (0.5%) screws were classified as grade 3. The use of Artis Zeego was associated with a significantly lower screw malplacement rate than was the use of fluoroscopy (p < 0.001). CONCLUSIONS: Our results demonstrated that pedicle screw placement with Artis Zeego was associated with a lower malplacement rate than was conventional two-dimensional fluoroscopy. No severe malplacement was observed in the Artis Zeego group. Thus, Artis Zeego could be a good option for improving pedicle screw accuracy.
format Online
Article
Text
id pubmed-9254419
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-92544192022-07-06 Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study Matsuoka, Akira Toyone, Tomoaki Okano, Ichiro Kudo, Yoshifumi Ishikawa, Koji Maruyama, Hiroshi Ozawa, Tomoyuki Shirahata, Toshiyuki Inagaki, Katsunori BMC Musculoskelet Disord Research BACKGROUND: The pedicle screw system is widely used in spine surgery, and it provides rigid fixation and leads to successful subsequent deformity correction and bony fusion. The standard imaging technique for pedicle screw insertion is two-dimensional images obtained from C-arm-type X-ray fluoroscopy. Artis Zeego is an emerging intraoperative imaging technique that can provide conventional two-dimensional fluoroscopic images and rapid three-dimensional fluoroscopic computed tomography reconstruction imaging. The aim of this study is to compare the insertion accuracies of PS placement using Artis Zeego and conventional 2D X-ray fluoroscopy. METHODS: In this study, we retrospectively reviewed the postoperative images of thoracolumbar fusion patients who underwent surgery using pedicle screws between 2013 and 2018. Pedicle screw malplacement was assessed using a four-grade classification by Rao et al. Misplacement rates were compared between pedicle screws assisted with Artis Zeego and two-dimensional fluoroscopy. RESULTS: A total of 1107 pedicle screws in 153 patients were inserted using Artis Zeego, and 427 pedicle screws in 80 patients were inserted using fluoroscopy. The overall perforation rate was 4.2% (46 perforations of 1106 pedicle screws) in the Artis Zeego group and 7.7% (33 perforations of 427 pedicle screws) in the fluoroscopy group. In the Artis Zeego group, 43 (3.9%) screws were classified as grade 1, and three (0.3%) screws were classified as grade 2. In the fluoroscopy group, 21 (4.9%) screws were classified as grade 1, 10 (2.3%) screws were classified as grade 2, and 2 (0.5%) screws were classified as grade 3. The use of Artis Zeego was associated with a significantly lower screw malplacement rate than was the use of fluoroscopy (p < 0.001). CONCLUSIONS: Our results demonstrated that pedicle screw placement with Artis Zeego was associated with a lower malplacement rate than was conventional two-dimensional fluoroscopy. No severe malplacement was observed in the Artis Zeego group. Thus, Artis Zeego could be a good option for improving pedicle screw accuracy. BioMed Central 2022-07-05 /pmc/articles/PMC9254419/ /pubmed/35790951 http://dx.doi.org/10.1186/s12891-022-05602-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Matsuoka, Akira
Toyone, Tomoaki
Okano, Ichiro
Kudo, Yoshifumi
Ishikawa, Koji
Maruyama, Hiroshi
Ozawa, Tomoyuki
Shirahata, Toshiyuki
Inagaki, Katsunori
Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
title Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
title_full Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
title_fullStr Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
title_full_unstemmed Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
title_short Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
title_sort comparison of pedicle screw placement accuracy between two types of imaging support (artis zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9254419/
https://www.ncbi.nlm.nih.gov/pubmed/35790951
http://dx.doi.org/10.1186/s12891-022-05602-4
work_keys_str_mv AT matsuokaakira comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT toyonetomoaki comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT okanoichiro comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT kudoyoshifumi comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT ishikawakoji comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT maruyamahiroshi comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT ozawatomoyuki comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT shirahatatoshiyuki comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy
AT inagakikatsunori comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy