Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study
BACKGROUND: The pedicle screw system is widely used in spine surgery, and it provides rigid fixation and leads to successful subsequent deformity correction and bony fusion. The standard imaging technique for pedicle screw insertion is two-dimensional images obtained from C-arm-type X-ray fluoroscop...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9254419/ https://www.ncbi.nlm.nih.gov/pubmed/35790951 http://dx.doi.org/10.1186/s12891-022-05602-4 |
_version_ | 1784740694832709632 |
---|---|
author | Matsuoka, Akira Toyone, Tomoaki Okano, Ichiro Kudo, Yoshifumi Ishikawa, Koji Maruyama, Hiroshi Ozawa, Tomoyuki Shirahata, Toshiyuki Inagaki, Katsunori |
author_facet | Matsuoka, Akira Toyone, Tomoaki Okano, Ichiro Kudo, Yoshifumi Ishikawa, Koji Maruyama, Hiroshi Ozawa, Tomoyuki Shirahata, Toshiyuki Inagaki, Katsunori |
author_sort | Matsuoka, Akira |
collection | PubMed |
description | BACKGROUND: The pedicle screw system is widely used in spine surgery, and it provides rigid fixation and leads to successful subsequent deformity correction and bony fusion. The standard imaging technique for pedicle screw insertion is two-dimensional images obtained from C-arm-type X-ray fluoroscopy. Artis Zeego is an emerging intraoperative imaging technique that can provide conventional two-dimensional fluoroscopic images and rapid three-dimensional fluoroscopic computed tomography reconstruction imaging. The aim of this study is to compare the insertion accuracies of PS placement using Artis Zeego and conventional 2D X-ray fluoroscopy. METHODS: In this study, we retrospectively reviewed the postoperative images of thoracolumbar fusion patients who underwent surgery using pedicle screws between 2013 and 2018. Pedicle screw malplacement was assessed using a four-grade classification by Rao et al. Misplacement rates were compared between pedicle screws assisted with Artis Zeego and two-dimensional fluoroscopy. RESULTS: A total of 1107 pedicle screws in 153 patients were inserted using Artis Zeego, and 427 pedicle screws in 80 patients were inserted using fluoroscopy. The overall perforation rate was 4.2% (46 perforations of 1106 pedicle screws) in the Artis Zeego group and 7.7% (33 perforations of 427 pedicle screws) in the fluoroscopy group. In the Artis Zeego group, 43 (3.9%) screws were classified as grade 1, and three (0.3%) screws were classified as grade 2. In the fluoroscopy group, 21 (4.9%) screws were classified as grade 1, 10 (2.3%) screws were classified as grade 2, and 2 (0.5%) screws were classified as grade 3. The use of Artis Zeego was associated with a significantly lower screw malplacement rate than was the use of fluoroscopy (p < 0.001). CONCLUSIONS: Our results demonstrated that pedicle screw placement with Artis Zeego was associated with a lower malplacement rate than was conventional two-dimensional fluoroscopy. No severe malplacement was observed in the Artis Zeego group. Thus, Artis Zeego could be a good option for improving pedicle screw accuracy. |
format | Online Article Text |
id | pubmed-9254419 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92544192022-07-06 Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study Matsuoka, Akira Toyone, Tomoaki Okano, Ichiro Kudo, Yoshifumi Ishikawa, Koji Maruyama, Hiroshi Ozawa, Tomoyuki Shirahata, Toshiyuki Inagaki, Katsunori BMC Musculoskelet Disord Research BACKGROUND: The pedicle screw system is widely used in spine surgery, and it provides rigid fixation and leads to successful subsequent deformity correction and bony fusion. The standard imaging technique for pedicle screw insertion is two-dimensional images obtained from C-arm-type X-ray fluoroscopy. Artis Zeego is an emerging intraoperative imaging technique that can provide conventional two-dimensional fluoroscopic images and rapid three-dimensional fluoroscopic computed tomography reconstruction imaging. The aim of this study is to compare the insertion accuracies of PS placement using Artis Zeego and conventional 2D X-ray fluoroscopy. METHODS: In this study, we retrospectively reviewed the postoperative images of thoracolumbar fusion patients who underwent surgery using pedicle screws between 2013 and 2018. Pedicle screw malplacement was assessed using a four-grade classification by Rao et al. Misplacement rates were compared between pedicle screws assisted with Artis Zeego and two-dimensional fluoroscopy. RESULTS: A total of 1107 pedicle screws in 153 patients were inserted using Artis Zeego, and 427 pedicle screws in 80 patients were inserted using fluoroscopy. The overall perforation rate was 4.2% (46 perforations of 1106 pedicle screws) in the Artis Zeego group and 7.7% (33 perforations of 427 pedicle screws) in the fluoroscopy group. In the Artis Zeego group, 43 (3.9%) screws were classified as grade 1, and three (0.3%) screws were classified as grade 2. In the fluoroscopy group, 21 (4.9%) screws were classified as grade 1, 10 (2.3%) screws were classified as grade 2, and 2 (0.5%) screws were classified as grade 3. The use of Artis Zeego was associated with a significantly lower screw malplacement rate than was the use of fluoroscopy (p < 0.001). CONCLUSIONS: Our results demonstrated that pedicle screw placement with Artis Zeego was associated with a lower malplacement rate than was conventional two-dimensional fluoroscopy. No severe malplacement was observed in the Artis Zeego group. Thus, Artis Zeego could be a good option for improving pedicle screw accuracy. BioMed Central 2022-07-05 /pmc/articles/PMC9254419/ /pubmed/35790951 http://dx.doi.org/10.1186/s12891-022-05602-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Matsuoka, Akira Toyone, Tomoaki Okano, Ichiro Kudo, Yoshifumi Ishikawa, Koji Maruyama, Hiroshi Ozawa, Tomoyuki Shirahata, Toshiyuki Inagaki, Katsunori Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study |
title | Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study |
title_full | Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study |
title_fullStr | Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study |
title_full_unstemmed | Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study |
title_short | Comparison of pedicle screw placement accuracy between two types of imaging support (Artis Zeego versus two-dimensional fluoroscopy): a cross-sectional observational study |
title_sort | comparison of pedicle screw placement accuracy between two types of imaging support (artis zeego versus two-dimensional fluoroscopy): a cross-sectional observational study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9254419/ https://www.ncbi.nlm.nih.gov/pubmed/35790951 http://dx.doi.org/10.1186/s12891-022-05602-4 |
work_keys_str_mv | AT matsuokaakira comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT toyonetomoaki comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT okanoichiro comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT kudoyoshifumi comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT ishikawakoji comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT maruyamahiroshi comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT ozawatomoyuki comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT shirahatatoshiyuki comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy AT inagakikatsunori comparisonofpediclescrewplacementaccuracybetweentwotypesofimagingsupportartiszeegoversustwodimensionalfluoroscopyacrosssectionalobservationalstudy |