Reliability assessment of the upper urinary tract dilation grading system based on magnetic resonance urography in patients with neurogenic bladder

BACKGROUND: To assess the inter-observer and intra-observer reliability of the magnetic resonance urography (MRU)—upper urinary tract dilation (UUTD) grading system. METHODS: A total of 40 patients with a diagnosis of NB were enrolled in this study. The images were assembled in an electronic present...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Zhonghan, Liao, Limin, Li, Xing, Wang, Xuesheng, Li, Xunhua, Zhao, Hui, Deng, Han, Liu, Qinggang, Gao, Yi, Jing, Huafang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9254662/
https://www.ncbi.nlm.nih.gov/pubmed/35787264
http://dx.doi.org/10.1186/s12894-022-01039-y
Descripción
Sumario:BACKGROUND: To assess the inter-observer and intra-observer reliability of the magnetic resonance urography (MRU)—upper urinary tract dilation (UUTD) grading system. METHODS: A total of 40 patients with a diagnosis of NB were enrolled in this study. The images were assembled in an electronic presentation randomly. The presentations were reviewed and graded by 4 junior and 4 senior urologists. One week later, the images were randomized again and reassessed. The inter-observer reliability was estimated by Kendall’s coefficient of concordance and intra-class correlation coefficient (ICC), and the intra-observer reliability was estimated by weighted Cohen’s kappa. RESULTS: The inter-observer reliability strength was excellent for all urologists, with the ICC value of 0.939 (0.908–0.963) and Kendall’s W value of 0.967. The highest agreement was shown in Grade 4 at 92.50%, and the lowest in Grade 2 at 82.14%. All disagreements were within one grade of difference. Moreover, the Intra-observer reliability was excellent, with the weighted kappa value ranging from 0.904 to 0.954. CONCLUSIONS: The inter-observer and intra-observer reliability of this novel MRU-UUTD grading system is confirmed, providing adequate evidence for broader clinical application.