Determination of the Influence of Strut Connector on Stent Deployment

Coronary artery stents are tubular structures employed together with angioplasty. Stented angioplasty is a clinical procedure widely applied in the treatment of atherosclerosis to reopen the blocked artery. It is a simple and fast curing minimally invasive clinical procedure. However, it is essentia...

Descripción completa

Detalles Bibliográficos
Autores principales: Hashim, V., Resmi, S. L., Dileep, P. N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9256422/
https://www.ncbi.nlm.nih.gov/pubmed/35800119
http://dx.doi.org/10.1155/2022/7232809
_version_ 1784741109728018432
author Hashim, V.
Resmi, S. L.
Dileep, P. N.
author_facet Hashim, V.
Resmi, S. L.
Dileep, P. N.
author_sort Hashim, V.
collection PubMed
description Coronary artery stents are tubular structures employed together with angioplasty. Stented angioplasty is a clinical procedure widely applied in the treatment of atherosclerosis to reopen the blocked artery. It is a simple and fast curing minimally invasive clinical procedure. However, it is essential to understand the expansion characteristics of a stent before implantation since the stent geometry, inflating pressure, etc., influence the performance of stents. Finite element analysis and in vitro experiments are simultaneously employed before clinical testing to predict the characteristics during deployment. In this paper, the expansion and deployment characteristics of Meril Osum 2.75 × 24 coronary stent and Envision 3.5 × 28 stent were investigated to study the influence of strut connector on the expansion behaviour of the stent by experimental and computational methods. The current study analyzes the real-time deployment characteristics such as rate of expansion, stress on stent, recoil, dog boning, and foreshortening. The stent expansion characteristics obtained from experiments and simulations were found matching and observed that strut connector has a significant effect on stent expansion. Further, the curved connector of small radius of curvature shows better performance with high patency rate.
format Online
Article
Text
id pubmed-9256422
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-92564222022-07-06 Determination of the Influence of Strut Connector on Stent Deployment Hashim, V. Resmi, S. L. Dileep, P. N. Appl Bionics Biomech Research Article Coronary artery stents are tubular structures employed together with angioplasty. Stented angioplasty is a clinical procedure widely applied in the treatment of atherosclerosis to reopen the blocked artery. It is a simple and fast curing minimally invasive clinical procedure. However, it is essential to understand the expansion characteristics of a stent before implantation since the stent geometry, inflating pressure, etc., influence the performance of stents. Finite element analysis and in vitro experiments are simultaneously employed before clinical testing to predict the characteristics during deployment. In this paper, the expansion and deployment characteristics of Meril Osum 2.75 × 24 coronary stent and Envision 3.5 × 28 stent were investigated to study the influence of strut connector on the expansion behaviour of the stent by experimental and computational methods. The current study analyzes the real-time deployment characteristics such as rate of expansion, stress on stent, recoil, dog boning, and foreshortening. The stent expansion characteristics obtained from experiments and simulations were found matching and observed that strut connector has a significant effect on stent expansion. Further, the curved connector of small radius of curvature shows better performance with high patency rate. Hindawi 2022-06-28 /pmc/articles/PMC9256422/ /pubmed/35800119 http://dx.doi.org/10.1155/2022/7232809 Text en Copyright © 2022 V. Hashim et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hashim, V.
Resmi, S. L.
Dileep, P. N.
Determination of the Influence of Strut Connector on Stent Deployment
title Determination of the Influence of Strut Connector on Stent Deployment
title_full Determination of the Influence of Strut Connector on Stent Deployment
title_fullStr Determination of the Influence of Strut Connector on Stent Deployment
title_full_unstemmed Determination of the Influence of Strut Connector on Stent Deployment
title_short Determination of the Influence of Strut Connector on Stent Deployment
title_sort determination of the influence of strut connector on stent deployment
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9256422/
https://www.ncbi.nlm.nih.gov/pubmed/35800119
http://dx.doi.org/10.1155/2022/7232809
work_keys_str_mv AT hashimv determinationoftheinfluenceofstrutconnectoronstentdeployment
AT resmisl determinationoftheinfluenceofstrutconnectoronstentdeployment
AT dileeppn determinationoftheinfluenceofstrutconnectoronstentdeployment