Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study
BACKGROUND: Fractional exhaled nitric oxide (FeNO) is promising for diagnosing asthma and could replace bronchial provocation (BP). To date, cut-off values have been derived by post hoc analysis only. The aim was to validate the diagnostic accuracy for predefined FeNO cut-off values and the predicti...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9256551/ https://www.ncbi.nlm.nih.gov/pubmed/35812996 http://dx.doi.org/10.1016/j.eclinm.2022.101533 |
_version_ | 1784741139059834880 |
---|---|
author | Schneider, Antonius Brunn, Benjamin Hapfelmeier, Alexander Schultz, Konrad Kellerer, Christina Jörres, Rudolf A. |
author_facet | Schneider, Antonius Brunn, Benjamin Hapfelmeier, Alexander Schultz, Konrad Kellerer, Christina Jörres, Rudolf A. |
author_sort | Schneider, Antonius |
collection | PubMed |
description | BACKGROUND: Fractional exhaled nitric oxide (FeNO) is promising for diagnosing asthma and could replace bronchial provocation (BP). To date, cut-off values have been derived by post hoc analysis only. The aim was to validate the diagnostic accuracy for predefined FeNO cut-off values and the predictive value for responsiveness to inhaled corticosteroids (ICS). METHODS: We conducted a prospective, diagnostic, multicentre study with patients attending three private practices of pneumologists in Upper Bavaria, Germany, from July 3, 2020 to Jan 21, 2022. Index test was FENO measurement. Reference standard was Tiffeneau ratio (FEV(1)/VC) or airway resistance as assessed by whole body plethysmography, with additional BP or bronchodilation test. Follow-up was performed after 12 weeks. Analyses of Receiver Operating Characteristics curves were conducted to determine the diagnostic accuracy and predictive value of FeNO. FINDINGS: 308 patients with complete follow-up were recruited, 186 (60·4%) were female, average age was 44·7 years, 161 (52·3%) had asthma. Regarding diagnostic accuracy, the area under the curve (AUC) was 0·718 (95% CI 0·661–0·775; p < 0·001). Sensitivity at FeNO >50 ppb was 0·24 (95% CI 0·18–0·32), specificity 0·99 (0·95–1·0), positive predictive value (PPV) 0·95 (0·84–0·99), negative predictive value (NPV) 0·54 (0·48–0·60). In 66 patients with ´wheezing´ and ´allergic rhinitis´, the sensitivity at FeNO >33 ppb was 0·49 (0·34–0·64), specificity 0·88 (0·64–0·99), PPV 0·92 (0·75–0·99), NPV 0·38 (0·23–0·54). In 68 patients with ICS medication, responsiveness was predicted at the cut-off >43 ppb, with a sensitivity of 0·55 (95%CI 0·36–0·74), specificity 0·82 (0·66–0·92), PPV 0·70 (0·47–0·87), NPV 0·71 (0·56–0·84). INTERPRETATION: FeNO measurement allows a valid ruling-in of an asthma diagnosis, whereas ruling-out of asthma is not possible. Enhanced probability of ICS responsiveness is also given with increased FeNO values. FUNDING: Circassia Germany gave 25% discount on the purchase of three NIOX VERO devices. |
format | Online Article Text |
id | pubmed-9256551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-92565512022-07-07 Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study Schneider, Antonius Brunn, Benjamin Hapfelmeier, Alexander Schultz, Konrad Kellerer, Christina Jörres, Rudolf A. eClinicalMedicine Articles BACKGROUND: Fractional exhaled nitric oxide (FeNO) is promising for diagnosing asthma and could replace bronchial provocation (BP). To date, cut-off values have been derived by post hoc analysis only. The aim was to validate the diagnostic accuracy for predefined FeNO cut-off values and the predictive value for responsiveness to inhaled corticosteroids (ICS). METHODS: We conducted a prospective, diagnostic, multicentre study with patients attending three private practices of pneumologists in Upper Bavaria, Germany, from July 3, 2020 to Jan 21, 2022. Index test was FENO measurement. Reference standard was Tiffeneau ratio (FEV(1)/VC) or airway resistance as assessed by whole body plethysmography, with additional BP or bronchodilation test. Follow-up was performed after 12 weeks. Analyses of Receiver Operating Characteristics curves were conducted to determine the diagnostic accuracy and predictive value of FeNO. FINDINGS: 308 patients with complete follow-up were recruited, 186 (60·4%) were female, average age was 44·7 years, 161 (52·3%) had asthma. Regarding diagnostic accuracy, the area under the curve (AUC) was 0·718 (95% CI 0·661–0·775; p < 0·001). Sensitivity at FeNO >50 ppb was 0·24 (95% CI 0·18–0·32), specificity 0·99 (0·95–1·0), positive predictive value (PPV) 0·95 (0·84–0·99), negative predictive value (NPV) 0·54 (0·48–0·60). In 66 patients with ´wheezing´ and ´allergic rhinitis´, the sensitivity at FeNO >33 ppb was 0·49 (0·34–0·64), specificity 0·88 (0·64–0·99), PPV 0·92 (0·75–0·99), NPV 0·38 (0·23–0·54). In 68 patients with ICS medication, responsiveness was predicted at the cut-off >43 ppb, with a sensitivity of 0·55 (95%CI 0·36–0·74), specificity 0·82 (0·66–0·92), PPV 0·70 (0·47–0·87), NPV 0·71 (0·56–0·84). INTERPRETATION: FeNO measurement allows a valid ruling-in of an asthma diagnosis, whereas ruling-out of asthma is not possible. Enhanced probability of ICS responsiveness is also given with increased FeNO values. FUNDING: Circassia Germany gave 25% discount on the purchase of three NIOX VERO devices. Elsevier 2022-07-01 /pmc/articles/PMC9256551/ /pubmed/35812996 http://dx.doi.org/10.1016/j.eclinm.2022.101533 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Articles Schneider, Antonius Brunn, Benjamin Hapfelmeier, Alexander Schultz, Konrad Kellerer, Christina Jörres, Rudolf A. Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study |
title | Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study |
title_full | Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study |
title_fullStr | Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study |
title_full_unstemmed | Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study |
title_short | Diagnostic accuracy of FeNO in asthma and predictive value for inhaled corticosteroid responsiveness: A prospective, multicentre study |
title_sort | diagnostic accuracy of feno in asthma and predictive value for inhaled corticosteroid responsiveness: a prospective, multicentre study |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9256551/ https://www.ncbi.nlm.nih.gov/pubmed/35812996 http://dx.doi.org/10.1016/j.eclinm.2022.101533 |
work_keys_str_mv | AT schneiderantonius diagnosticaccuracyoffenoinasthmaandpredictivevalueforinhaledcorticosteroidresponsivenessaprospectivemulticentrestudy AT brunnbenjamin diagnosticaccuracyoffenoinasthmaandpredictivevalueforinhaledcorticosteroidresponsivenessaprospectivemulticentrestudy AT hapfelmeieralexander diagnosticaccuracyoffenoinasthmaandpredictivevalueforinhaledcorticosteroidresponsivenessaprospectivemulticentrestudy AT schultzkonrad diagnosticaccuracyoffenoinasthmaandpredictivevalueforinhaledcorticosteroidresponsivenessaprospectivemulticentrestudy AT kellererchristina diagnosticaccuracyoffenoinasthmaandpredictivevalueforinhaledcorticosteroidresponsivenessaprospectivemulticentrestudy AT jorresrudolfa diagnosticaccuracyoffenoinasthmaandpredictivevalueforinhaledcorticosteroidresponsivenessaprospectivemulticentrestudy |