Knowledge-based automatic plan optimization for left-sided whole breast tomotherapy

BACKGROUND/PURPOSE: Tomotherapy may deliver high-quality whole breast irradiation at static angles. The aim of this study was to implement Knowledge-Based (KB) automatic planning for left-sided whole breast using this modality. MATERIALS/METHODS: Virtual volumetric plans were associated to the dose...

Descripción completa

Detalles Bibliográficos
Autores principales: Esposito, Pier Giorgio, Castriconi, Roberta, Mangili, Paola, Broggi, Sara, Fodor, Andrei, Pasetti, Marcella, Tudda, Alessia, Di Muzio, Nadia Gisella, del Vecchio, Antonella, Fiorino, Claudio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9256826/
https://www.ncbi.nlm.nih.gov/pubmed/35814259
http://dx.doi.org/10.1016/j.phro.2022.06.009
Descripción
Sumario:BACKGROUND/PURPOSE: Tomotherapy may deliver high-quality whole breast irradiation at static angles. The aim of this study was to implement Knowledge-Based (KB) automatic planning for left-sided whole breast using this modality. MATERIALS/METHODS: Virtual volumetric plans were associated to the dose distributions of 69 Tomotherapy (TT) clinical plans of previously treated patients, aiming to train a KB-model using a commercial tool completely implemented in our treatment planning system. An individually optimized template based on the resulting KB-model was generated for automatic plan optimization. Thirty patients of the training set and ten new patients were considered for internal/external validation. Fully-automatic plans (KB-TT) were generated and compared using the same geometry/number of fields of the corresponding clinical plans. RESULTS: KB-TT plans were successfully generated in 26/30 and 10/10 patients of the internal/external validation sets; for 4 patients whose original plans used only two fields, the manual insertion of one/two fields before running the automatic template was sufficient to obtain acceptable plans. Concerning internal validation, planning target volume V(95%)/D(1%)/dose distribution standard deviation improved by 0.9%/0.4Gy/0.2Gy (p < 0.05) against clinical plans; Organs at risk mean doses were also slightly improved (p < 0.05) by 0.07/0.4/0.2/0.01 Gy for left lung/heart/right breast/right lung respectively. Similarly satisfactory results were replicated in the external validation set. The resulting treatment duration was 8 ± 1 min, consistent with our clinical experience. The active planner time per patient was 5–10 minutes. CONCLUSION: Automatic TT left-sided breast KB-plans are comparable to or slightly better than clinical plans and can be obtained with limited planner time. The approach is currently under clinical implementation.