Cargando…

An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm

Although retrograde in situ branched stent grafting (RIBS) is one possible treatment option for thoracic aortic aneurysms, concerns exist regarding the durability of the stent graft (SG) at the junction between the main SG and the branched SG. We report on the autopsy results of a patient treated wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Shukuzawa, Kota, Baba, Takeshi, Nishie, Ryosuke, Ozawa, Hirotsugu, Omori, Makiko, Hara, Masayuki, Tachihara, Hiromasa, Ohki, Takao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9260453/
https://www.ncbi.nlm.nih.gov/pubmed/35812121
http://dx.doi.org/10.1016/j.jvscit.2022.04.007
_version_ 1784742033587437568
author Shukuzawa, Kota
Baba, Takeshi
Nishie, Ryosuke
Ozawa, Hirotsugu
Omori, Makiko
Hara, Masayuki
Tachihara, Hiromasa
Ohki, Takao
author_facet Shukuzawa, Kota
Baba, Takeshi
Nishie, Ryosuke
Ozawa, Hirotsugu
Omori, Makiko
Hara, Masayuki
Tachihara, Hiromasa
Ohki, Takao
author_sort Shukuzawa, Kota
collection PubMed
description Although retrograde in situ branched stent grafting (RIBS) is one possible treatment option for thoracic aortic aneurysms, concerns exist regarding the durability of the stent graft (SG) at the junction between the main SG and the branched SG. We report on the autopsy results of a patient treated with RIBS for a complex aortic arch aneurysm. The patient had died of a nonaortic cause 14 months after the RIBS procedure. On computed tomography analysis and a leak test, the harvested SG was intact without any stent fracture, stenosis, or junctional leak at 1 atm water pressure (760 mm Hg).
format Online
Article
Text
id pubmed-9260453
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-92604532022-07-08 An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm Shukuzawa, Kota Baba, Takeshi Nishie, Ryosuke Ozawa, Hirotsugu Omori, Makiko Hara, Masayuki Tachihara, Hiromasa Ohki, Takao J Vasc Surg Cases Innov Tech Case report Although retrograde in situ branched stent grafting (RIBS) is one possible treatment option for thoracic aortic aneurysms, concerns exist regarding the durability of the stent graft (SG) at the junction between the main SG and the branched SG. We report on the autopsy results of a patient treated with RIBS for a complex aortic arch aneurysm. The patient had died of a nonaortic cause 14 months after the RIBS procedure. On computed tomography analysis and a leak test, the harvested SG was intact without any stent fracture, stenosis, or junctional leak at 1 atm water pressure (760 mm Hg). Elsevier 2022-05-12 /pmc/articles/PMC9260453/ /pubmed/35812121 http://dx.doi.org/10.1016/j.jvscit.2022.04.007 Text en © 2022 Published by Elsevier Inc. on behalf of Society for Vascular Surgery. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Shukuzawa, Kota
Baba, Takeshi
Nishie, Ryosuke
Ozawa, Hirotsugu
Omori, Makiko
Hara, Masayuki
Tachihara, Hiromasa
Ohki, Takao
An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm
title An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm
title_full An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm
title_fullStr An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm
title_full_unstemmed An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm
title_short An autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm
title_sort autopsy case of retrograde in situ branched stent grafting for a complex aortic arch aneurysm
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9260453/
https://www.ncbi.nlm.nih.gov/pubmed/35812121
http://dx.doi.org/10.1016/j.jvscit.2022.04.007
work_keys_str_mv AT shukuzawakota anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT babatakeshi anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT nishieryosuke anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT ozawahirotsugu anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT omorimakiko anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT haramasayuki anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT tachiharahiromasa anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT ohkitakao anautopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT shukuzawakota autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT babatakeshi autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT nishieryosuke autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT ozawahirotsugu autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT omorimakiko autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT haramasayuki autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT tachiharahiromasa autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm
AT ohkitakao autopsycaseofretrogradeinsitubranchedstentgraftingforacomplexaorticarchaneurysm