Cargando…

Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles

[Image: see text] Ultrasonic flotation is useful for fine low-rank coal purification; however, the efficiency of ultrasonic flotation still needs to be improved. Because the dynamic behavior of flotation bubbles has significant effects on their flotation efficiency, it was investigated under differe...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Kuidong, Liu, Hong, Sun, Liqing, Zhang, Zhihua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9260756/
https://www.ncbi.nlm.nih.gov/pubmed/35811855
http://dx.doi.org/10.1021/acsomega.2c01162
_version_ 1784742107263533056
author Gao, Kuidong
Liu, Hong
Sun, Liqing
Zhang, Zhihua
author_facet Gao, Kuidong
Liu, Hong
Sun, Liqing
Zhang, Zhihua
author_sort Gao, Kuidong
collection PubMed
description [Image: see text] Ultrasonic flotation is useful for fine low-rank coal purification; however, the efficiency of ultrasonic flotation still needs to be improved. Because the dynamic behavior of flotation bubbles has significant effects on their flotation efficiency, it was investigated under different gas input conditions with and without ultrasound using the volume of fluid method and h-speed imaging. The results indicated that the gas input method can influence the final kinetic behavior of the flotation bubbles by changing the morphology of the initial bubble. With an increase in the size and aspect ratio of the bubble, the bubble deformation and velocity increased, and the range of motion of the bubble increased and then decreased. Meanwhile, the size of the bubble increased with an increase in the thickness of the vibrating plate of the ultrasonic transducer owing to the aggregation of the bubbles under the influence of ultrasound.
format Online
Article
Text
id pubmed-9260756
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-92607562022-07-08 Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles Gao, Kuidong Liu, Hong Sun, Liqing Zhang, Zhihua ACS Omega [Image: see text] Ultrasonic flotation is useful for fine low-rank coal purification; however, the efficiency of ultrasonic flotation still needs to be improved. Because the dynamic behavior of flotation bubbles has significant effects on their flotation efficiency, it was investigated under different gas input conditions with and without ultrasound using the volume of fluid method and h-speed imaging. The results indicated that the gas input method can influence the final kinetic behavior of the flotation bubbles by changing the morphology of the initial bubble. With an increase in the size and aspect ratio of the bubble, the bubble deformation and velocity increased, and the range of motion of the bubble increased and then decreased. Meanwhile, the size of the bubble increased with an increase in the thickness of the vibrating plate of the ultrasonic transducer owing to the aggregation of the bubbles under the influence of ultrasound. American Chemical Society 2022-06-22 /pmc/articles/PMC9260756/ /pubmed/35811855 http://dx.doi.org/10.1021/acsomega.2c01162 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Gao, Kuidong
Liu, Hong
Sun, Liqing
Zhang, Zhihua
Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles
title Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles
title_full Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles
title_fullStr Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles
title_full_unstemmed Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles
title_short Effect of Gas Input Conditions and Ultrasound on the Dynamic Behavior of Flotation Bubbles
title_sort effect of gas input conditions and ultrasound on the dynamic behavior of flotation bubbles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9260756/
https://www.ncbi.nlm.nih.gov/pubmed/35811855
http://dx.doi.org/10.1021/acsomega.2c01162
work_keys_str_mv AT gaokuidong effectofgasinputconditionsandultrasoundonthedynamicbehaviorofflotationbubbles
AT liuhong effectofgasinputconditionsandultrasoundonthedynamicbehaviorofflotationbubbles
AT sunliqing effectofgasinputconditionsandultrasoundonthedynamicbehaviorofflotationbubbles
AT zhangzhihua effectofgasinputconditionsandultrasoundonthedynamicbehaviorofflotationbubbles