Cargando…
Electrical Response of Poly(N-[3-(dimethylamino)Propyl] Methacrylamide) to CO(2) at a Long Exposure Period
[Image: see text] Amine-functionalized polymers (AFPs) are able to react with carbon dioxide (CO(2)) and are therefore useful in CO(2) capture and sensing. To develop AFP-based CO(2) sensors, it is critical to examine their electrical responses to CO(2) over long periods of time, so that the device...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9260916/ https://www.ncbi.nlm.nih.gov/pubmed/35811921 http://dx.doi.org/10.1021/acsomega.2c00914 |
_version_ | 1784742149694160896 |
---|---|
author | Shahrbabaki, Zahra Oveissi, Farshad Farajikhah, Syamak Ghasemian, Mohammad B. Jansen-van Vuuren, Ross D. Jessop, Philip G. Yun, Jimmy Dehghani, Fariba Naficy, Sina |
author_facet | Shahrbabaki, Zahra Oveissi, Farshad Farajikhah, Syamak Ghasemian, Mohammad B. Jansen-van Vuuren, Ross D. Jessop, Philip G. Yun, Jimmy Dehghani, Fariba Naficy, Sina |
author_sort | Shahrbabaki, Zahra |
collection | PubMed |
description | [Image: see text] Amine-functionalized polymers (AFPs) are able to react with carbon dioxide (CO(2)) and are therefore useful in CO(2) capture and sensing. To develop AFP-based CO(2) sensors, it is critical to examine their electrical responses to CO(2) over long periods of time, so that the device can be used consistently for measuring CO(2) concentration. To this end, we synthesized poly(N-[3-(dimethylamino)propyl] methacrylamide) (pDMAPMAm) by free radical polymerization and tested its ability to behave as a CO(2)-responsive polymer in a transducer. The electrical response of this polymer to CO(2) upon long exposure times was measured in both the aqueous and solid phases. Direct current resistance measurement tests on pDMAPMAm films printed along with the silver electrodes in the presence of CO(2) at various concentrations reveal a two-region electrical response. Upon continuous exposure to different CO(2) flow rates (at a constant pressure of 0.2 MPa), the resistance first decreased over time, reaching a minimum, followed by a gradual increase with further exposure to CO(2). A similar trend is observed when CO(2) is introduced to an aqueous solution of pDMAPMAm. The in situ monitoring of pH suggests that the change in resistance of pDMAPMAm can be attributed to the protonation of tertiary amine groups in the presence of CO(2). This two-region response of pDMAPMAm is based on a proton-hopping mechanism and a change in the number of free amines when pDMAPMAm is exposed to various levels of CO(2). |
format | Online Article Text |
id | pubmed-9260916 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-92609162022-07-08 Electrical Response of Poly(N-[3-(dimethylamino)Propyl] Methacrylamide) to CO(2) at a Long Exposure Period Shahrbabaki, Zahra Oveissi, Farshad Farajikhah, Syamak Ghasemian, Mohammad B. Jansen-van Vuuren, Ross D. Jessop, Philip G. Yun, Jimmy Dehghani, Fariba Naficy, Sina ACS Omega [Image: see text] Amine-functionalized polymers (AFPs) are able to react with carbon dioxide (CO(2)) and are therefore useful in CO(2) capture and sensing. To develop AFP-based CO(2) sensors, it is critical to examine their electrical responses to CO(2) over long periods of time, so that the device can be used consistently for measuring CO(2) concentration. To this end, we synthesized poly(N-[3-(dimethylamino)propyl] methacrylamide) (pDMAPMAm) by free radical polymerization and tested its ability to behave as a CO(2)-responsive polymer in a transducer. The electrical response of this polymer to CO(2) upon long exposure times was measured in both the aqueous and solid phases. Direct current resistance measurement tests on pDMAPMAm films printed along with the silver electrodes in the presence of CO(2) at various concentrations reveal a two-region electrical response. Upon continuous exposure to different CO(2) flow rates (at a constant pressure of 0.2 MPa), the resistance first decreased over time, reaching a minimum, followed by a gradual increase with further exposure to CO(2). A similar trend is observed when CO(2) is introduced to an aqueous solution of pDMAPMAm. The in situ monitoring of pH suggests that the change in resistance of pDMAPMAm can be attributed to the protonation of tertiary amine groups in the presence of CO(2). This two-region response of pDMAPMAm is based on a proton-hopping mechanism and a change in the number of free amines when pDMAPMAm is exposed to various levels of CO(2). American Chemical Society 2022-06-22 /pmc/articles/PMC9260916/ /pubmed/35811921 http://dx.doi.org/10.1021/acsomega.2c00914 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Shahrbabaki, Zahra Oveissi, Farshad Farajikhah, Syamak Ghasemian, Mohammad B. Jansen-van Vuuren, Ross D. Jessop, Philip G. Yun, Jimmy Dehghani, Fariba Naficy, Sina Electrical Response of Poly(N-[3-(dimethylamino)Propyl] Methacrylamide) to CO(2) at a Long Exposure Period |
title | Electrical Response of Poly(N-[3-(dimethylamino)Propyl]
Methacrylamide) to CO(2) at a Long Exposure Period |
title_full | Electrical Response of Poly(N-[3-(dimethylamino)Propyl]
Methacrylamide) to CO(2) at a Long Exposure Period |
title_fullStr | Electrical Response of Poly(N-[3-(dimethylamino)Propyl]
Methacrylamide) to CO(2) at a Long Exposure Period |
title_full_unstemmed | Electrical Response of Poly(N-[3-(dimethylamino)Propyl]
Methacrylamide) to CO(2) at a Long Exposure Period |
title_short | Electrical Response of Poly(N-[3-(dimethylamino)Propyl]
Methacrylamide) to CO(2) at a Long Exposure Period |
title_sort | electrical response of poly(n-[3-(dimethylamino)propyl]
methacrylamide) to co(2) at a long exposure period |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9260916/ https://www.ncbi.nlm.nih.gov/pubmed/35811921 http://dx.doi.org/10.1021/acsomega.2c00914 |
work_keys_str_mv | AT shahrbabakizahra electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT oveissifarshad electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT farajikhahsyamak electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT ghasemianmohammadb electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT jansenvanvuurenrossd electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT jessopphilipg electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT yunjimmy electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT dehghanifariba electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod AT naficysina electricalresponseofpolyn3dimethylaminopropylmethacrylamidetoco2atalongexposureperiod |