Cargando…
Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
PURPOSE: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures. METHODS: Six trainees and a staff radiologist performed TN-targeting punctures...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Ultrasound in Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9262671/ https://www.ncbi.nlm.nih.gov/pubmed/35108776 http://dx.doi.org/10.14366/usg.21211 |
_version_ | 1784742555763605504 |
---|---|
author | Lee, Haein Cho, Yoon Joo Ha, Eun Ju Moon, Jayoung Kim, You Na Kim, Minji Lee, Kyung-Min An, Sung Hyun |
author_facet | Lee, Haein Cho, Yoon Joo Ha, Eun Ju Moon, Jayoung Kim, You Na Kim, Minji Lee, Kyung-Min An, Sung Hyun |
author_sort | Lee, Haein |
collection | PubMed |
description | PURPOSE: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures. METHODS: Six trainees and a staff radiologist performed TN-targeting punctures with or without the NGS in phantom models (group 1, experience <50 cases; group 2, experience ≥50 cases and <100 cases; group 3, experience ≥100 cases of TN-targeting punctures). The feasibility, technical success rate, number of punctures, and procedure time were recorded. RESULTS: The feasibility of NGS was 98.6% (138/140). In group 1, the technical success rate increased from 60.0%±8.2% to 80.0%±8.2% when the NGS was used (P=0.046), with a reduction in the number of punctures from 2.2 to 1.2 (P=0.005). In group 2, the rate changed from 95.0%±5.8% to 100.0%±0.0% with the NGS (P=0.157), with a minimal decrease in the number of punctures from 1.1 to 1.0 (P=0.157). The procedure time significantly decreased in both groups (P=0.041 and P=0.010, respectively) when the NGS was used. In group 3, there were no significant differences in the technical success rate and the number of punctures according to whether the NGS was used (P=0.317 and P=0.317, respectively). CONCLUSION: NGS using standard needle magnetization is technically feasible and has potential to improve the efficacy of TN-targeting punctures for less-experienced operators, especially beginners, according to the findings of this phantom study. |
format | Online Article Text |
id | pubmed-9262671 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Korean Society of Ultrasound in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-92626712022-07-12 Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study Lee, Haein Cho, Yoon Joo Ha, Eun Ju Moon, Jayoung Kim, You Na Kim, Minji Lee, Kyung-Min An, Sung Hyun Ultrasonography Original Article PURPOSE: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures. METHODS: Six trainees and a staff radiologist performed TN-targeting punctures with or without the NGS in phantom models (group 1, experience <50 cases; group 2, experience ≥50 cases and <100 cases; group 3, experience ≥100 cases of TN-targeting punctures). The feasibility, technical success rate, number of punctures, and procedure time were recorded. RESULTS: The feasibility of NGS was 98.6% (138/140). In group 1, the technical success rate increased from 60.0%±8.2% to 80.0%±8.2% when the NGS was used (P=0.046), with a reduction in the number of punctures from 2.2 to 1.2 (P=0.005). In group 2, the rate changed from 95.0%±5.8% to 100.0%±0.0% with the NGS (P=0.157), with a minimal decrease in the number of punctures from 1.1 to 1.0 (P=0.157). The procedure time significantly decreased in both groups (P=0.041 and P=0.010, respectively) when the NGS was used. In group 3, there were no significant differences in the technical success rate and the number of punctures according to whether the NGS was used (P=0.317 and P=0.317, respectively). CONCLUSION: NGS using standard needle magnetization is technically feasible and has potential to improve the efficacy of TN-targeting punctures for less-experienced operators, especially beginners, according to the findings of this phantom study. Korean Society of Ultrasound in Medicine 2022-07 2021-12-10 /pmc/articles/PMC9262671/ /pubmed/35108776 http://dx.doi.org/10.14366/usg.21211 Text en Copyright © 2022 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Haein Cho, Yoon Joo Ha, Eun Ju Moon, Jayoung Kim, You Na Kim, Minji Lee, Kyung-Min An, Sung Hyun Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study |
title | Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study |
title_full | Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study |
title_fullStr | Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study |
title_full_unstemmed | Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study |
title_short | Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study |
title_sort | technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9262671/ https://www.ncbi.nlm.nih.gov/pubmed/35108776 http://dx.doi.org/10.14366/usg.21211 |
work_keys_str_mv | AT leehaein technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy AT choyoonjoo technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy AT haeunju technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy AT moonjayoung technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy AT kimyouna technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy AT kimminji technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy AT leekyungmin technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy AT ansunghyun technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy |