Cargando…

Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study

PURPOSE: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures. METHODS: Six trainees and a staff radiologist performed TN-targeting punctures...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Haein, Cho, Yoon Joo, Ha, Eun Ju, Moon, Jayoung, Kim, You Na, Kim, Minji, Lee, Kyung-Min, An, Sung Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9262671/
https://www.ncbi.nlm.nih.gov/pubmed/35108776
http://dx.doi.org/10.14366/usg.21211
_version_ 1784742555763605504
author Lee, Haein
Cho, Yoon Joo
Ha, Eun Ju
Moon, Jayoung
Kim, You Na
Kim, Minji
Lee, Kyung-Min
An, Sung Hyun
author_facet Lee, Haein
Cho, Yoon Joo
Ha, Eun Ju
Moon, Jayoung
Kim, You Na
Kim, Minji
Lee, Kyung-Min
An, Sung Hyun
author_sort Lee, Haein
collection PubMed
description PURPOSE: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures. METHODS: Six trainees and a staff radiologist performed TN-targeting punctures with or without the NGS in phantom models (group 1, experience <50 cases; group 2, experience ≥50 cases and <100 cases; group 3, experience ≥100 cases of TN-targeting punctures). The feasibility, technical success rate, number of punctures, and procedure time were recorded. RESULTS: The feasibility of NGS was 98.6% (138/140). In group 1, the technical success rate increased from 60.0%±8.2% to 80.0%±8.2% when the NGS was used (P=0.046), with a reduction in the number of punctures from 2.2 to 1.2 (P=0.005). In group 2, the rate changed from 95.0%±5.8% to 100.0%±0.0% with the NGS (P=0.157), with a minimal decrease in the number of punctures from 1.1 to 1.0 (P=0.157). The procedure time significantly decreased in both groups (P=0.041 and P=0.010, respectively) when the NGS was used. In group 3, there were no significant differences in the technical success rate and the number of punctures according to whether the NGS was used (P=0.317 and P=0.317, respectively). CONCLUSION: NGS using standard needle magnetization is technically feasible and has potential to improve the efficacy of TN-targeting punctures for less-experienced operators, especially beginners, according to the findings of this phantom study.
format Online
Article
Text
id pubmed-9262671
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-92626712022-07-12 Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study Lee, Haein Cho, Yoon Joo Ha, Eun Ju Moon, Jayoung Kim, You Na Kim, Minji Lee, Kyung-Min An, Sung Hyun Ultrasonography Original Article PURPOSE: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures. METHODS: Six trainees and a staff radiologist performed TN-targeting punctures with or without the NGS in phantom models (group 1, experience <50 cases; group 2, experience ≥50 cases and <100 cases; group 3, experience ≥100 cases of TN-targeting punctures). The feasibility, technical success rate, number of punctures, and procedure time were recorded. RESULTS: The feasibility of NGS was 98.6% (138/140). In group 1, the technical success rate increased from 60.0%±8.2% to 80.0%±8.2% when the NGS was used (P=0.046), with a reduction in the number of punctures from 2.2 to 1.2 (P=0.005). In group 2, the rate changed from 95.0%±5.8% to 100.0%±0.0% with the NGS (P=0.157), with a minimal decrease in the number of punctures from 1.1 to 1.0 (P=0.157). The procedure time significantly decreased in both groups (P=0.041 and P=0.010, respectively) when the NGS was used. In group 3, there were no significant differences in the technical success rate and the number of punctures according to whether the NGS was used (P=0.317 and P=0.317, respectively). CONCLUSION: NGS using standard needle magnetization is technically feasible and has potential to improve the efficacy of TN-targeting punctures for less-experienced operators, especially beginners, according to the findings of this phantom study. Korean Society of Ultrasound in Medicine 2022-07 2021-12-10 /pmc/articles/PMC9262671/ /pubmed/35108776 http://dx.doi.org/10.14366/usg.21211 Text en Copyright © 2022 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Haein
Cho, Yoon Joo
Ha, Eun Ju
Moon, Jayoung
Kim, You Na
Kim, Minji
Lee, Kyung-Min
An, Sung Hyun
Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
title Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
title_full Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
title_fullStr Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
title_full_unstemmed Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
title_short Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
title_sort technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9262671/
https://www.ncbi.nlm.nih.gov/pubmed/35108776
http://dx.doi.org/10.14366/usg.21211
work_keys_str_mv AT leehaein technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy
AT choyoonjoo technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy
AT haeunju technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy
AT moonjayoung technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy
AT kimyouna technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy
AT kimminji technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy
AT leekyungmin technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy
AT ansunghyun technicalfeasibilityandefficacyofastandardneedlemagnetizationsystemforultrasoundneedleguidanceinthyroidnoduletargetingpuncturesaphantomstudy