Cargando…
Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization
The loosening of traditional prosthetics is among the leading causes of surgical failure of proximal femoral bone defects. A novel compound sleeve and stem prosthesis was designed using an optimization methodology that combined an octet-truss porous structure with density-based topology optimization...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9263260/ https://www.ncbi.nlm.nih.gov/pubmed/35813996 http://dx.doi.org/10.3389/fbioe.2022.938337 |
_version_ | 1784742693091409920 |
---|---|
author | Xue, Haowen Bai, Haotian Zhou, Rongqi Wang, Jincheng Zhou, Bin Wang, Xiaonan Luo, Wenbin Zhao, Xin |
author_facet | Xue, Haowen Bai, Haotian Zhou, Rongqi Wang, Jincheng Zhou, Bin Wang, Xiaonan Luo, Wenbin Zhao, Xin |
author_sort | Xue, Haowen |
collection | PubMed |
description | The loosening of traditional prosthetics is among the leading causes of surgical failure of proximal femoral bone defects. A novel compound sleeve and stem prosthesis was designed using an optimization methodology that combined an octet-truss porous structure with density-based topology optimization to improve stability, promote bone ingrowth, and enhance biomechanical properties. Biomechanical changes were assessed using finite element analysis. The distribution of stress, the strain energy density, and the relative micromotion in the optimized group were considered. The optimized sleeve prosthesis achieved a 31.5% weight reduction. The maximum stresses in the optimized group were observed to decrease by 30.33 and 4.74% at the back sleeve and neck part of stem prosthesis, with a 29.52% increase in the femur, respectively. The average stress in most selected regions in the optimized group was significantly greater than that in the original group (p < 0.05). The maximum relative micromotion decreased by 15.18% (from 63.9 to 54.2 μm) in the optimized group. The novel designed compound sleeve and stem prosthesis could effectively improve the biomechanical performance of next-generation prosthetics and provide a microenvironment for bone ingrowth. The presented method could serve as a model for clinical practice and a platform for future orthopedic surgery applications. |
format | Online Article Text |
id | pubmed-9263260 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-92632602022-07-09 Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization Xue, Haowen Bai, Haotian Zhou, Rongqi Wang, Jincheng Zhou, Bin Wang, Xiaonan Luo, Wenbin Zhao, Xin Front Bioeng Biotechnol Bioengineering and Biotechnology The loosening of traditional prosthetics is among the leading causes of surgical failure of proximal femoral bone defects. A novel compound sleeve and stem prosthesis was designed using an optimization methodology that combined an octet-truss porous structure with density-based topology optimization to improve stability, promote bone ingrowth, and enhance biomechanical properties. Biomechanical changes were assessed using finite element analysis. The distribution of stress, the strain energy density, and the relative micromotion in the optimized group were considered. The optimized sleeve prosthesis achieved a 31.5% weight reduction. The maximum stresses in the optimized group were observed to decrease by 30.33 and 4.74% at the back sleeve and neck part of stem prosthesis, with a 29.52% increase in the femur, respectively. The average stress in most selected regions in the optimized group was significantly greater than that in the original group (p < 0.05). The maximum relative micromotion decreased by 15.18% (from 63.9 to 54.2 μm) in the optimized group. The novel designed compound sleeve and stem prosthesis could effectively improve the biomechanical performance of next-generation prosthetics and provide a microenvironment for bone ingrowth. The presented method could serve as a model for clinical practice and a platform for future orthopedic surgery applications. Frontiers Media S.A. 2022-06-24 /pmc/articles/PMC9263260/ /pubmed/35813996 http://dx.doi.org/10.3389/fbioe.2022.938337 Text en Copyright © 2022 Xue, Bai, Zhou, Wang, Zhou, Wang, Luo and Zhao. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Xue, Haowen Bai, Haotian Zhou, Rongqi Wang, Jincheng Zhou, Bin Wang, Xiaonan Luo, Wenbin Zhao, Xin Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization |
title | Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization |
title_full | Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization |
title_fullStr | Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization |
title_full_unstemmed | Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization |
title_short | Novel Design of the Compound Sleeve and Stem Prosthesis for Treatment of Proximal Femur Bone Defects Based on Topology Optimization |
title_sort | novel design of the compound sleeve and stem prosthesis for treatment of proximal femur bone defects based on topology optimization |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9263260/ https://www.ncbi.nlm.nih.gov/pubmed/35813996 http://dx.doi.org/10.3389/fbioe.2022.938337 |
work_keys_str_mv | AT xuehaowen noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization AT baihaotian noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization AT zhourongqi noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization AT wangjincheng noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization AT zhoubin noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization AT wangxiaonan noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization AT luowenbin noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization AT zhaoxin noveldesignofthecompoundsleeveandstemprosthesisfortreatmentofproximalfemurbonedefectsbasedontopologyoptimization |