Cargando…

Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs

BACKGROUND: Alveolar air leakage from a pleural defect around the staple line is one of the complications after wedge resection of the lung. An intraoperative closure of the pleural defect by suturing can cause additional pleural rupture due to tension of the pleura adjacent to staple lines. Therefo...

Descripción completa

Detalles Bibliográficos
Autores principales: Suzuki, Takahiro, Asakura, Keisuke, Egawa, Takumi, Kawauchi, Masahiro, Okubo, Yu, Masai, Kyohei, Kaseda, Kaoru, Hishida, Tomoyuki, Asamura, Hisao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9264071/
https://www.ncbi.nlm.nih.gov/pubmed/35813731
http://dx.doi.org/10.21037/jtd-21-1960
_version_ 1784742892965724160
author Suzuki, Takahiro
Asakura, Keisuke
Egawa, Takumi
Kawauchi, Masahiro
Okubo, Yu
Masai, Kyohei
Kaseda, Kaoru
Hishida, Tomoyuki
Asamura, Hisao
author_facet Suzuki, Takahiro
Asakura, Keisuke
Egawa, Takumi
Kawauchi, Masahiro
Okubo, Yu
Masai, Kyohei
Kaseda, Kaoru
Hishida, Tomoyuki
Asamura, Hisao
author_sort Suzuki, Takahiro
collection PubMed
description BACKGROUND: Alveolar air leakage from a pleural defect around the staple line is one of the complications after wedge resection of the lung. An intraoperative closure of the pleural defect by suturing can cause additional pleural rupture due to tension of the pleura adjacent to staple lines. Therefore, we have introduced a novel closure method for pleural defect adjacent to the staple line, named the double stapling method. This study compared the efficacy of two closure methods; the double stapling method and conventional suturing method with pledgets using ex vivo porcine lungs. METHODS: The double stapling method involves closing the pleural defect by suturing the two parallel staple lines at both sides of the pleural defect. This method was developed to distribute the pleural tension around the needle holes of suturing. As a model of pleural defect adjacent to the staple line after wedge resection, wedge resection of the caudal lobe of left porcine lungs was performed, and a superficial square pleural defect (10 mm × 10 mm) adjacent to the staple line was made by scalpel. The defect was closed using the following two methods: (I) suturing with pledgets (n=10); and (II) double stapling method (n=10). The lobe was inflated in water at an airway pressure of 20, 25, and 30 cmH(2)O; closure success or failure was judged by the absence or presence of air leakage. RESULTS: The closure success was confirmed in 2 (20%) out of 10 cases in the suturing with pledgets group and 9 (90%) out of 10 in the double stapling method group (P=0.007). In 4 out of 10 cases in the suturing with pledgets group, new pleural clefts longer than 3 mm were created around the needle holes of suturing. CONCLUSIONS: Ex vivo experiments have suggested the superiority of the double stapling method for the intraoperative closure of alveolar air leakage adjacent to the staple line after wedge resection, compared to conventional suturing with the pledget method.
format Online
Article
Text
id pubmed-9264071
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-92640712022-07-09 Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs Suzuki, Takahiro Asakura, Keisuke Egawa, Takumi Kawauchi, Masahiro Okubo, Yu Masai, Kyohei Kaseda, Kaoru Hishida, Tomoyuki Asamura, Hisao J Thorac Dis Original Article BACKGROUND: Alveolar air leakage from a pleural defect around the staple line is one of the complications after wedge resection of the lung. An intraoperative closure of the pleural defect by suturing can cause additional pleural rupture due to tension of the pleura adjacent to staple lines. Therefore, we have introduced a novel closure method for pleural defect adjacent to the staple line, named the double stapling method. This study compared the efficacy of two closure methods; the double stapling method and conventional suturing method with pledgets using ex vivo porcine lungs. METHODS: The double stapling method involves closing the pleural defect by suturing the two parallel staple lines at both sides of the pleural defect. This method was developed to distribute the pleural tension around the needle holes of suturing. As a model of pleural defect adjacent to the staple line after wedge resection, wedge resection of the caudal lobe of left porcine lungs was performed, and a superficial square pleural defect (10 mm × 10 mm) adjacent to the staple line was made by scalpel. The defect was closed using the following two methods: (I) suturing with pledgets (n=10); and (II) double stapling method (n=10). The lobe was inflated in water at an airway pressure of 20, 25, and 30 cmH(2)O; closure success or failure was judged by the absence or presence of air leakage. RESULTS: The closure success was confirmed in 2 (20%) out of 10 cases in the suturing with pledgets group and 9 (90%) out of 10 in the double stapling method group (P=0.007). In 4 out of 10 cases in the suturing with pledgets group, new pleural clefts longer than 3 mm were created around the needle holes of suturing. CONCLUSIONS: Ex vivo experiments have suggested the superiority of the double stapling method for the intraoperative closure of alveolar air leakage adjacent to the staple line after wedge resection, compared to conventional suturing with the pledget method. AME Publishing Company 2022-06 /pmc/articles/PMC9264071/ /pubmed/35813731 http://dx.doi.org/10.21037/jtd-21-1960 Text en 2022 Journal of Thoracic Disease. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Suzuki, Takahiro
Asakura, Keisuke
Egawa, Takumi
Kawauchi, Masahiro
Okubo, Yu
Masai, Kyohei
Kaseda, Kaoru
Hishida, Tomoyuki
Asamura, Hisao
Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs
title Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs
title_full Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs
title_fullStr Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs
title_full_unstemmed Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs
title_short Double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs
title_sort double stapling method for closure of intraoperative alveolar air leakage adjacent to the staple line: a randomized experimental study on ex vivo porcine lungs
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9264071/
https://www.ncbi.nlm.nih.gov/pubmed/35813731
http://dx.doi.org/10.21037/jtd-21-1960
work_keys_str_mv AT suzukitakahiro doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT asakurakeisuke doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT egawatakumi doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT kawauchimasahiro doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT okuboyu doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT masaikyohei doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT kasedakaoru doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT hishidatomoyuki doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs
AT asamurahisao doublestaplingmethodforclosureofintraoperativealveolarairleakageadjacenttothestaplelinearandomizedexperimentalstudyonexvivoporcinelungs