Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
BACKGROUND: An arteriovenous fistula is an abnormal arteriovenous shunt between an artery and a vein, which often leads to venous congestion in the central nervous system. The blood flow near the fistula is different from normal artery flow. A novel method to detect the abnormal shunting flow or pre...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Association of Neurological Surgeons
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9265175/ https://www.ncbi.nlm.nih.gov/pubmed/35854859 http://dx.doi.org/10.3171/CASE21172 |
_version_ | 1784743148237357056 |
---|---|
author | Shimoda, Yoshiteru Sonobe, Shinya Niizuma, Kuniyasu Endo, Toshiki Endo, Hidenori Otomo, Mayuko Tominaga, Teiji |
author_facet | Shimoda, Yoshiteru Sonobe, Shinya Niizuma, Kuniyasu Endo, Toshiki Endo, Hidenori Otomo, Mayuko Tominaga, Teiji |
author_sort | Shimoda, Yoshiteru |
collection | PubMed |
description | BACKGROUND: An arteriovenous fistula is an abnormal arteriovenous shunt between an artery and a vein, which often leads to venous congestion in the central nervous system. The blood flow near the fistula is different from normal artery flow. A novel method to detect the abnormal shunting flow or pressure near the fistula is needed. OBSERVATIONS: A 76-year-old woman presented to the authors’ institute with progressive right upper limb weakness. Right vertebral angiography showed a fistula between the right extracranial vertebral artery (VA) and the right vertebral venous plexus at the C7 level. The patient underwent endovascular treatment for shunt flow reduction. Before the procedure, blood pressures were measured at the proximal VA, distal VA near the fistula, and just at the fistula and drainer using a microcatheter. The blood pressure waveforms were characteristically different in terms of resistance index, half-decay time, and appearance of dicrotic notch. The fistula was embolized with coils and N-butyl cyanoacrylate solution. LESSONS: During endovascular treatment, the authors were able to digitally record the vascular pressure waveform from the tip of the microcatheter and succeeded in calculating several parameters that characterize the shunting flow. Furthermore, these parameters could help recognize the abnormal blood flow, allowing a safer endovascular surgery. |
format | Online Article Text |
id | pubmed-9265175 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Association of Neurological Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-92651752022-07-18 Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case Shimoda, Yoshiteru Sonobe, Shinya Niizuma, Kuniyasu Endo, Toshiki Endo, Hidenori Otomo, Mayuko Tominaga, Teiji J Neurosurg Case Lessons Case Lesson BACKGROUND: An arteriovenous fistula is an abnormal arteriovenous shunt between an artery and a vein, which often leads to venous congestion in the central nervous system. The blood flow near the fistula is different from normal artery flow. A novel method to detect the abnormal shunting flow or pressure near the fistula is needed. OBSERVATIONS: A 76-year-old woman presented to the authors’ institute with progressive right upper limb weakness. Right vertebral angiography showed a fistula between the right extracranial vertebral artery (VA) and the right vertebral venous plexus at the C7 level. The patient underwent endovascular treatment for shunt flow reduction. Before the procedure, blood pressures were measured at the proximal VA, distal VA near the fistula, and just at the fistula and drainer using a microcatheter. The blood pressure waveforms were characteristically different in terms of resistance index, half-decay time, and appearance of dicrotic notch. The fistula was embolized with coils and N-butyl cyanoacrylate solution. LESSONS: During endovascular treatment, the authors were able to digitally record the vascular pressure waveform from the tip of the microcatheter and succeeded in calculating several parameters that characterize the shunting flow. Furthermore, these parameters could help recognize the abnormal blood flow, allowing a safer endovascular surgery. American Association of Neurological Surgeons 2021-07-12 /pmc/articles/PMC9265175/ /pubmed/35854859 http://dx.doi.org/10.3171/CASE21172 Text en © 2021 The authors https://creativecommons.org/licenses/by-nc-nd/4.0/CC BY-NC-ND 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ). |
spellingShingle | Case Lesson Shimoda, Yoshiteru Sonobe, Shinya Niizuma, Kuniyasu Endo, Toshiki Endo, Hidenori Otomo, Mayuko Tominaga, Teiji Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case |
title | Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case |
title_full | Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case |
title_fullStr | Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case |
title_full_unstemmed | Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case |
title_short | Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case |
title_sort | digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case |
topic | Case Lesson |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9265175/ https://www.ncbi.nlm.nih.gov/pubmed/35854859 http://dx.doi.org/10.3171/CASE21172 |
work_keys_str_mv | AT shimodayoshiteru digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase AT sonobeshinya digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase AT niizumakuniyasu digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase AT endotoshiki digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase AT endohidenori digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase AT otomomayuko digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase AT tominagateiji digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase |