Cargando…

Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case

BACKGROUND: An arteriovenous fistula is an abnormal arteriovenous shunt between an artery and a vein, which often leads to venous congestion in the central nervous system. The blood flow near the fistula is different from normal artery flow. A novel method to detect the abnormal shunting flow or pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Shimoda, Yoshiteru, Sonobe, Shinya, Niizuma, Kuniyasu, Endo, Toshiki, Endo, Hidenori, Otomo, Mayuko, Tominaga, Teiji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Association of Neurological Surgeons 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9265175/
https://www.ncbi.nlm.nih.gov/pubmed/35854859
http://dx.doi.org/10.3171/CASE21172
_version_ 1784743148237357056
author Shimoda, Yoshiteru
Sonobe, Shinya
Niizuma, Kuniyasu
Endo, Toshiki
Endo, Hidenori
Otomo, Mayuko
Tominaga, Teiji
author_facet Shimoda, Yoshiteru
Sonobe, Shinya
Niizuma, Kuniyasu
Endo, Toshiki
Endo, Hidenori
Otomo, Mayuko
Tominaga, Teiji
author_sort Shimoda, Yoshiteru
collection PubMed
description BACKGROUND: An arteriovenous fistula is an abnormal arteriovenous shunt between an artery and a vein, which often leads to venous congestion in the central nervous system. The blood flow near the fistula is different from normal artery flow. A novel method to detect the abnormal shunting flow or pressure near the fistula is needed. OBSERVATIONS: A 76-year-old woman presented to the authors’ institute with progressive right upper limb weakness. Right vertebral angiography showed a fistula between the right extracranial vertebral artery (VA) and the right vertebral venous plexus at the C7 level. The patient underwent endovascular treatment for shunt flow reduction. Before the procedure, blood pressures were measured at the proximal VA, distal VA near the fistula, and just at the fistula and drainer using a microcatheter. The blood pressure waveforms were characteristically different in terms of resistance index, half-decay time, and appearance of dicrotic notch. The fistula was embolized with coils and N-butyl cyanoacrylate solution. LESSONS: During endovascular treatment, the authors were able to digitally record the vascular pressure waveform from the tip of the microcatheter and succeeded in calculating several parameters that characterize the shunting flow. Furthermore, these parameters could help recognize the abnormal blood flow, allowing a safer endovascular surgery.
format Online
Article
Text
id pubmed-9265175
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Association of Neurological Surgeons
record_format MEDLINE/PubMed
spelling pubmed-92651752022-07-18 Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case Shimoda, Yoshiteru Sonobe, Shinya Niizuma, Kuniyasu Endo, Toshiki Endo, Hidenori Otomo, Mayuko Tominaga, Teiji J Neurosurg Case Lessons Case Lesson BACKGROUND: An arteriovenous fistula is an abnormal arteriovenous shunt between an artery and a vein, which often leads to venous congestion in the central nervous system. The blood flow near the fistula is different from normal artery flow. A novel method to detect the abnormal shunting flow or pressure near the fistula is needed. OBSERVATIONS: A 76-year-old woman presented to the authors’ institute with progressive right upper limb weakness. Right vertebral angiography showed a fistula between the right extracranial vertebral artery (VA) and the right vertebral venous plexus at the C7 level. The patient underwent endovascular treatment for shunt flow reduction. Before the procedure, blood pressures were measured at the proximal VA, distal VA near the fistula, and just at the fistula and drainer using a microcatheter. The blood pressure waveforms were characteristically different in terms of resistance index, half-decay time, and appearance of dicrotic notch. The fistula was embolized with coils and N-butyl cyanoacrylate solution. LESSONS: During endovascular treatment, the authors were able to digitally record the vascular pressure waveform from the tip of the microcatheter and succeeded in calculating several parameters that characterize the shunting flow. Furthermore, these parameters could help recognize the abnormal blood flow, allowing a safer endovascular surgery. American Association of Neurological Surgeons 2021-07-12 /pmc/articles/PMC9265175/ /pubmed/35854859 http://dx.doi.org/10.3171/CASE21172 Text en © 2021 The authors https://creativecommons.org/licenses/by-nc-nd/4.0/CC BY-NC-ND 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Case Lesson
Shimoda, Yoshiteru
Sonobe, Shinya
Niizuma, Kuniyasu
Endo, Toshiki
Endo, Hidenori
Otomo, Mayuko
Tominaga, Teiji
Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
title Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
title_full Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
title_fullStr Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
title_full_unstemmed Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
title_short Digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
title_sort digital intravascular pressure wave recording during endovascular treatment reveals abnormal shunting flow in vertebral venous fistula of the vertebral artery: illustrative case
topic Case Lesson
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9265175/
https://www.ncbi.nlm.nih.gov/pubmed/35854859
http://dx.doi.org/10.3171/CASE21172
work_keys_str_mv AT shimodayoshiteru digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase
AT sonobeshinya digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase
AT niizumakuniyasu digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase
AT endotoshiki digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase
AT endohidenori digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase
AT otomomayuko digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase
AT tominagateiji digitalintravascularpressurewaverecordingduringendovasculartreatmentrevealsabnormalshuntingflowinvertebralvenousfistulaofthevertebralarteryillustrativecase