Cargando…

Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles

Periodic technical inspection (PTI) of vehicles guarantees safety and environmental compliance during their lifetime. Particulate matter emissions of diesel vehicles are controlled with opacity measurements. After the introduction of diesel particulate filters (DPFs), particulate matter emissions ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Melas, Anastasios, Selleri, Tommaso, Suarez-Bertoa, Ricardo, Giechaskiel, Barouch
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9265972/
https://www.ncbi.nlm.nih.gov/pubmed/35805262
http://dx.doi.org/10.3390/ijerph19137602
_version_ 1784743347765641216
author Melas, Anastasios
Selleri, Tommaso
Suarez-Bertoa, Ricardo
Giechaskiel, Barouch
author_facet Melas, Anastasios
Selleri, Tommaso
Suarez-Bertoa, Ricardo
Giechaskiel, Barouch
author_sort Melas, Anastasios
collection PubMed
description Periodic technical inspection (PTI) of vehicles guarantees safety and environmental compliance during their lifetime. Particulate matter emissions of diesel vehicles are controlled with opacity measurements. After the introduction of diesel particulate filters (DPFs), particulate matter emissions have drastically decreased and the sensitivity of the opacity method is questioned. Several countries have already or are planning to introduce a solid particle number (SPN) method at their PTI that will either substitute or complement opacity measurements. However, there are differences in the measurement procedures and the limit values. In this study, we compared the different approaches and investigated topics which are still not well defined, such as the uncertainty of the SPN-PTI instruments, repeatability of the procedures, impact of the DPF fill state, and the correlation between type-approval SPN emissions and SPN concentrations during PTI tests. Finally, we compared the SPN-PTI instruments with the opacity meters. Our results showed that SPN-PTI measurements can detect tampered and defective DPFs. We also made suggestions on the measurement procedures and the concentration limit.
format Online
Article
Text
id pubmed-9265972
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92659722022-07-09 Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles Melas, Anastasios Selleri, Tommaso Suarez-Bertoa, Ricardo Giechaskiel, Barouch Int J Environ Res Public Health Article Periodic technical inspection (PTI) of vehicles guarantees safety and environmental compliance during their lifetime. Particulate matter emissions of diesel vehicles are controlled with opacity measurements. After the introduction of diesel particulate filters (DPFs), particulate matter emissions have drastically decreased and the sensitivity of the opacity method is questioned. Several countries have already or are planning to introduce a solid particle number (SPN) method at their PTI that will either substitute or complement opacity measurements. However, there are differences in the measurement procedures and the limit values. In this study, we compared the different approaches and investigated topics which are still not well defined, such as the uncertainty of the SPN-PTI instruments, repeatability of the procedures, impact of the DPF fill state, and the correlation between type-approval SPN emissions and SPN concentrations during PTI tests. Finally, we compared the SPN-PTI instruments with the opacity meters. Our results showed that SPN-PTI measurements can detect tampered and defective DPFs. We also made suggestions on the measurement procedures and the concentration limit. MDPI 2022-06-21 /pmc/articles/PMC9265972/ /pubmed/35805262 http://dx.doi.org/10.3390/ijerph19137602 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Melas, Anastasios
Selleri, Tommaso
Suarez-Bertoa, Ricardo
Giechaskiel, Barouch
Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles
title Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles
title_full Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles
title_fullStr Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles
title_full_unstemmed Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles
title_short Evaluation of Measurement Procedures for Solid Particle Number (SPN) Measurements during the Periodic Technical Inspection (PTI) of Vehicles
title_sort evaluation of measurement procedures for solid particle number (spn) measurements during the periodic technical inspection (pti) of vehicles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9265972/
https://www.ncbi.nlm.nih.gov/pubmed/35805262
http://dx.doi.org/10.3390/ijerph19137602
work_keys_str_mv AT melasanastasios evaluationofmeasurementproceduresforsolidparticlenumberspnmeasurementsduringtheperiodictechnicalinspectionptiofvehicles
AT selleritommaso evaluationofmeasurementproceduresforsolidparticlenumberspnmeasurementsduringtheperiodictechnicalinspectionptiofvehicles
AT suarezbertoaricardo evaluationofmeasurementproceduresforsolidparticlenumberspnmeasurementsduringtheperiodictechnicalinspectionptiofvehicles
AT giechaskielbarouch evaluationofmeasurementproceduresforsolidparticlenumberspnmeasurementsduringtheperiodictechnicalinspectionptiofvehicles