Cargando…

The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials

The aim of this study was to tackle the topic of appropriate recommendations for artificial-saliva and mouthwash usage. The contact angle, pH, and conductivity of two artificial saliva solutions, four mouthwashes, and their mixtures on enamel, glass-ionomer, and composite dental materials were measu...

Descripción completa

Detalles Bibliográficos
Autores principales: Qureshi, Saima, Milić, Lazar, Petrović, Bojan, Vejin, Marija, Kojić, Sanja, Jarić, Stefan, Stojanović, Goran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9267139/
https://www.ncbi.nlm.nih.gov/pubmed/35806658
http://dx.doi.org/10.3390/ma15134533
_version_ 1784743644677275648
author Qureshi, Saima
Milić, Lazar
Petrović, Bojan
Vejin, Marija
Kojić, Sanja
Jarić, Stefan
Stojanović, Goran
author_facet Qureshi, Saima
Milić, Lazar
Petrović, Bojan
Vejin, Marija
Kojić, Sanja
Jarić, Stefan
Stojanović, Goran
author_sort Qureshi, Saima
collection PubMed
description The aim of this study was to tackle the topic of appropriate recommendations for artificial-saliva and mouthwash usage. The contact angle, pH, and conductivity of two artificial saliva solutions, four mouthwashes, and their mixtures on enamel, glass-ionomer, and composite dental materials were measured. The measurements were conducted with a MATLAB algorithm to minimize human error. The obtained values for the contact angle were in the range from 7.98° to 52.6°, and they showed completely nonlinear and nonuniform behavior for all investigated liquids and on all investigated substrates. Results reveal statistically significant differences among all tested liquids on all investigated substrates (p < 0.05). pH values ranged from 1.54 to 7.01. A wide range of conductivity values were observed, from 1205µS/cm in the saliva-stimulating solution to 6679 mS/cm in the artificial saliva. Spearman’s test showed a moderate positive correlation between the pH and conductivity of the tested fluids (R = 0.7108). A comparison of the data obtained using Image J software and the MATLAB algorithm showed consistency, not exceeding 5% error. When an experiment uses human material and bioactive materials THAT are used in biomedicine as substrates, an additional definition of protocols is highly recommended for future research on this topic.
format Online
Article
Text
id pubmed-9267139
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92671392022-07-09 The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials Qureshi, Saima Milić, Lazar Petrović, Bojan Vejin, Marija Kojić, Sanja Jarić, Stefan Stojanović, Goran Materials (Basel) Article The aim of this study was to tackle the topic of appropriate recommendations for artificial-saliva and mouthwash usage. The contact angle, pH, and conductivity of two artificial saliva solutions, four mouthwashes, and their mixtures on enamel, glass-ionomer, and composite dental materials were measured. The measurements were conducted with a MATLAB algorithm to minimize human error. The obtained values for the contact angle were in the range from 7.98° to 52.6°, and they showed completely nonlinear and nonuniform behavior for all investigated liquids and on all investigated substrates. Results reveal statistically significant differences among all tested liquids on all investigated substrates (p < 0.05). pH values ranged from 1.54 to 7.01. A wide range of conductivity values were observed, from 1205µS/cm in the saliva-stimulating solution to 6679 mS/cm in the artificial saliva. Spearman’s test showed a moderate positive correlation between the pH and conductivity of the tested fluids (R = 0.7108). A comparison of the data obtained using Image J software and the MATLAB algorithm showed consistency, not exceeding 5% error. When an experiment uses human material and bioactive materials THAT are used in biomedicine as substrates, an additional definition of protocols is highly recommended for future research on this topic. MDPI 2022-06-28 /pmc/articles/PMC9267139/ /pubmed/35806658 http://dx.doi.org/10.3390/ma15134533 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Qureshi, Saima
Milić, Lazar
Petrović, Bojan
Vejin, Marija
Kojić, Sanja
Jarić, Stefan
Stojanović, Goran
The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials
title The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials
title_full The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials
title_fullStr The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials
title_full_unstemmed The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials
title_short The Measurement of Contact Angle, pH, and Conductivity of Artificial Saliva and Mouthwashes on Enamel, Glass-Ionomer, and Composite Dental Materials
title_sort measurement of contact angle, ph, and conductivity of artificial saliva and mouthwashes on enamel, glass-ionomer, and composite dental materials
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9267139/
https://www.ncbi.nlm.nih.gov/pubmed/35806658
http://dx.doi.org/10.3390/ma15134533
work_keys_str_mv AT qureshisaima themeasurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT miliclazar themeasurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT petrovicbojan themeasurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT vejinmarija themeasurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT kojicsanja themeasurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT jaricstefan themeasurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT stojanovicgoran themeasurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT qureshisaima measurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT miliclazar measurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT petrovicbojan measurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT vejinmarija measurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT kojicsanja measurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT jaricstefan measurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials
AT stojanovicgoran measurementofcontactanglephandconductivityofartificialsalivaandmouthwashesonenamelglassionomerandcompositedentalmaterials