Cargando…
Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study
The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9267359/ https://www.ncbi.nlm.nih.gov/pubmed/35807131 http://dx.doi.org/10.3390/jcm11133846 |
_version_ | 1784743700141703168 |
---|---|
author | Sawicki, Paweł Regulski, Piotr Winiarski, Artur Zawadzki, Paweł J. |
author_facet | Sawicki, Paweł Regulski, Piotr Winiarski, Artur Zawadzki, Paweł J. |
author_sort | Sawicki, Paweł |
collection | PubMed |
description | The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two bone models and an implant-with-transfer model were scanned with 3shape E4 (3shape, Copenhagen, Denmark) laboratory scanner. Cone beam computed tomography (CBCT) images of two bone models were taken with different values of voltage (60, 70, 80, 90 kV), tube current (4, 10 mA) and voxel size (200, 300 µm). All the data were superimposed using planning software, and the measurements of buccal bone thickness in two selected regions were performed both using CBCT and scan cross-sections. The mean squared error (MSE) being the squared differences between measurements was used in the accuracy assessment of the CBCT device. A one-way ANOVA revealed significant differences between voltage and MSE (p = 0.044), as well as implant position and MSE (p = 0.005). The distortions of measurements depend on bone margin thickness, and the higher the distance to measure, the higher the error. Accurate measurements of buccal bone thickness (MSE below 0.25) were achieved with voltage values of 70, 80, and 90 kV. |
format | Online Article Text |
id | pubmed-9267359 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92673592022-07-09 Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study Sawicki, Paweł Regulski, Piotr Winiarski, Artur Zawadzki, Paweł J. J Clin Med Article The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two bone models and an implant-with-transfer model were scanned with 3shape E4 (3shape, Copenhagen, Denmark) laboratory scanner. Cone beam computed tomography (CBCT) images of two bone models were taken with different values of voltage (60, 70, 80, 90 kV), tube current (4, 10 mA) and voxel size (200, 300 µm). All the data were superimposed using planning software, and the measurements of buccal bone thickness in two selected regions were performed both using CBCT and scan cross-sections. The mean squared error (MSE) being the squared differences between measurements was used in the accuracy assessment of the CBCT device. A one-way ANOVA revealed significant differences between voltage and MSE (p = 0.044), as well as implant position and MSE (p = 0.005). The distortions of measurements depend on bone margin thickness, and the higher the distance to measure, the higher the error. Accurate measurements of buccal bone thickness (MSE below 0.25) were achieved with voltage values of 70, 80, and 90 kV. MDPI 2022-07-02 /pmc/articles/PMC9267359/ /pubmed/35807131 http://dx.doi.org/10.3390/jcm11133846 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sawicki, Paweł Regulski, Piotr Winiarski, Artur Zawadzki, Paweł J. Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study |
title | Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study |
title_full | Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study |
title_fullStr | Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study |
title_full_unstemmed | Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study |
title_short | Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study |
title_sort | influence of exposure parameters and implant position in peri-implant bone assessment in cbct images: an in vitro study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9267359/ https://www.ncbi.nlm.nih.gov/pubmed/35807131 http://dx.doi.org/10.3390/jcm11133846 |
work_keys_str_mv | AT sawickipaweł influenceofexposureparametersandimplantpositioninperiimplantboneassessmentincbctimagesaninvitrostudy AT regulskipiotr influenceofexposureparametersandimplantpositioninperiimplantboneassessmentincbctimagesaninvitrostudy AT winiarskiartur influenceofexposureparametersandimplantpositioninperiimplantboneassessmentincbctimagesaninvitrostudy AT zawadzkipawełj influenceofexposureparametersandimplantpositioninperiimplantboneassessmentincbctimagesaninvitrostudy |