Cargando…

Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis

This study aims to assess the role of Color Duplex Ultrasound with or without contrast media for surveillance following endovascular aortic aneurysm repair (EVAR). A systematic search of the literature published until April 2022 was performed according to the Preferred Reporting Items for Systematic...

Descripción completa

Detalles Bibliográficos
Autores principales: Karaolanis, Georgios I., Antonopoulos, Constantine N., Georgakarakos, Efstratios, Lianos, Georgios D., Mitsis, Michail, Glantzounis, Georgios K., Giannoukas, Athanasios, Kouvelos, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9267587/
https://www.ncbi.nlm.nih.gov/pubmed/35806912
http://dx.doi.org/10.3390/jcm11133628
_version_ 1784743756572917760
author Karaolanis, Georgios I.
Antonopoulos, Constantine N.
Georgakarakos, Efstratios
Lianos, Georgios D.
Mitsis, Michail
Glantzounis, Georgios K.
Giannoukas, Athanasios
Kouvelos, George
author_facet Karaolanis, Georgios I.
Antonopoulos, Constantine N.
Georgakarakos, Efstratios
Lianos, Georgios D.
Mitsis, Michail
Glantzounis, Georgios K.
Giannoukas, Athanasios
Kouvelos, George
author_sort Karaolanis, Georgios I.
collection PubMed
description This study aims to assess the role of Color Duplex Ultrasound with or without contrast media for surveillance following endovascular aortic aneurysm repair (EVAR). A systematic search of the literature published until April 2022 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The pooled rates of endoleak detection through Contrast-Enhanced or Color Duplex Ultrasound (CEUS or CDUS) and Computed Tomography Angiography (CTA) with 95% confidence intervals (CIs) were estimated using random-effect analysis. Thirty-eight studies were considered eligible for inclusion. The total number of patients in the included studies was 5214 between 1997 and 2021. The overall pooled rate of endoleak detection using CDUS and CTA was 82.59% and 97.22%, while the rates for CEUS and CTA were 96.67% and 92.82%, respectively. The findings of the present study support the use of the CEUS for endoleak detection. However, it should be integrated into institutional protocols for EVAR surveillance to further evaluate its clinical utility in the post-EVAR period before it can be recommended as the sole imaging modality after EVAR.
format Online
Article
Text
id pubmed-9267587
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92675872022-07-09 Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis Karaolanis, Georgios I. Antonopoulos, Constantine N. Georgakarakos, Efstratios Lianos, Georgios D. Mitsis, Michail Glantzounis, Georgios K. Giannoukas, Athanasios Kouvelos, George J Clin Med Review This study aims to assess the role of Color Duplex Ultrasound with or without contrast media for surveillance following endovascular aortic aneurysm repair (EVAR). A systematic search of the literature published until April 2022 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The pooled rates of endoleak detection through Contrast-Enhanced or Color Duplex Ultrasound (CEUS or CDUS) and Computed Tomography Angiography (CTA) with 95% confidence intervals (CIs) were estimated using random-effect analysis. Thirty-eight studies were considered eligible for inclusion. The total number of patients in the included studies was 5214 between 1997 and 2021. The overall pooled rate of endoleak detection using CDUS and CTA was 82.59% and 97.22%, while the rates for CEUS and CTA were 96.67% and 92.82%, respectively. The findings of the present study support the use of the CEUS for endoleak detection. However, it should be integrated into institutional protocols for EVAR surveillance to further evaluate its clinical utility in the post-EVAR period before it can be recommended as the sole imaging modality after EVAR. MDPI 2022-06-23 /pmc/articles/PMC9267587/ /pubmed/35806912 http://dx.doi.org/10.3390/jcm11133628 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Karaolanis, Georgios I.
Antonopoulos, Constantine N.
Georgakarakos, Efstratios
Lianos, Georgios D.
Mitsis, Michail
Glantzounis, Georgios K.
Giannoukas, Athanasios
Kouvelos, George
Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis
title Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis
title_full Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis
title_fullStr Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis
title_full_unstemmed Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis
title_short Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis
title_sort colour duplex and/or contrast-enhanced ultrasound compared with computed tomography angiography for endoleak detection after endovascular abdominal aortic aneurysm repair: a systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9267587/
https://www.ncbi.nlm.nih.gov/pubmed/35806912
http://dx.doi.org/10.3390/jcm11133628
work_keys_str_mv AT karaolanisgeorgiosi colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis
AT antonopoulosconstantinen colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis
AT georgakarakosefstratios colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis
AT lianosgeorgiosd colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis
AT mitsismichail colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis
AT glantzounisgeorgiosk colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis
AT giannoukasathanasios colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis
AT kouvelosgeorge colourduplexandorcontrastenhancedultrasoundcomparedwithcomputedtomographyangiographyforendoleakdetectionafterendovascularabdominalaorticaneurysmrepairasystematicreviewandmetaanalysis